manualshive.com logo in svg
background image

 

Pathport OCTO 

User Guide 

 

November 2018 

 

 

 

© 2018 Pathway Connectivity  

A Division of Acuity Brands Canada 

1439 17 Ave SE Calgary AB T2G 1J9 

403-243-8110 

www.pathwayconnect.com 

 

 

 

 

Содержание Pathport OCT

Страница 1: ...Pathport OCTO User Guide November 2018 2018 Pathway Connectivity A Division of Acuity Brands Canada 1439 17 Ave SE Calgary AB T2G 1J9 403 243 8110 www pathwayconnect com ...

Страница 2: ...ols Supported 5 Front Panel 7 Rear Panel 7 Front Panel Display 8 Setting Gateway Properties 9 Note Regarding ArtNet Shownet and Subnet Mask 11 Setting Port Properties 12 Contact Closure Input CC1 13 Advanced Configuration 13 Appendix 14 Electrical information 14 Compliance 14 ...

Страница 3: ...th other OCTOs and Pathport gateways as well as with a number of other Ethernet aware lighting control products such as consoles and controllers The OCTO like all Pathports is a routing device and does not provide control over the protocols or the data being passed It only provides control over the path the data takes how multiple DMX sources are treated merged or prioritized and certain other rou...

Страница 4: ...e humidity non condensing Warning The AC socket outlet shall be installed near the equipment and shall be easily accessible Warning This equipment relies on building installation primary overcurrent protection Warning Except for the IEC chassis plug marked for AC input all ports on the Pathport OCTO are intended for low voltage data lines only Attaching anything other than low voltage sources to t...

Страница 5: ... accepted Pathport Protocol A broadcast protocol developed by Pathway Connectivity and implemented by a variety of console manufacturers ArtNet A broadcast protocol developed by Artistic Licence Its free distribution has made in popular with media server manufacturers Because this is not a standard some implementations may not work with others Strand Shownet A proprietary broadcast protocol develo...

Страница 6: ...blished by ESTA which allows remote configuration of last mile DMX devices using the same wire pair that carries the DMX signal Like DMX RDM requires a separate dedicated controller to generate the signal packets the OCTO will route The freely available Pathscape software is required to use the OCTO as an RDM gateway to configure DMX based equipment ...

Страница 7: ...rts are 5 pin XLR 3 pin XLR or RJ45 Ethercon connectors mounted front or rear or terminals strip connectors rear only Rear Panel The RJ45 Ethercon network connection is located on the rear panel and cannot be front mounted The 2 pole Contact Closure Expansion port along with the AC input are located here also Model 6422 shown ...

Страница 8: ...k via the rear panel Ethercon port If no soft label name has been assigned to the gateway the IP address will be shown on the top line as well as the middle The subnet class shown after the IP on the middle line will be 8 16 or 24 which are respectively a Class A subnet mask of 255 0 0 0 a Class B subnet mask of 255 255 0 0 and a Class C subnet mask of 255 255 255 0 From the default display turn t...

Страница 9: ...turn to the previous menu level The following are the Node Configuration menu options Node Configuration Network Setup Device Info Status Protocol Support Utilities Back Network Setup Property Explanation Available Settings IP Address Set IP address for gateway Select then turn knob to set each octet Push to accept Subnet Mask Set subnet mask for gateway Select then turn knob to set each octet Pus...

Страница 10: ... MAC Address Reports gateway s MAC address Firmware Version Reports current firmware version Back Protocol Support Property Explanation Available Settings Art Net Rx receive Set gateway to listen for Artnet Enable default Disable sACN Rx receive Set gateway to listen for sACN Enable default Disable Shownet Rx receive Set gateway to listen for Shownet Enable default Disable Pathport Rx receive Set ...

Страница 11: ... the IP settings to factory values Includes properties such as signal loss that are set from Pathscape Back Note Regarding ArtNet Shownet and Subnet Mask The ArtNet protocol is explicitly sent to a broadcast address typically 2 255 255 255 or 10 255 255 255 The OCTO must have its subnet mask set wide enough to include this broadcast address When using ArtNet a Class A subnet mask of 255 0 0 0 is r...

Страница 12: ...ow appear beside the new setting Scroll to the bottom of the list and select Back to return to the previous menu level The following properties are available from Port Configuration Further options may be added from time to time Property Explanation Available Settings DMX Port Turns blue power light on off Enable default Disable Port Direction Sets DMX direction for port Input Output default Patch...

Страница 13: ...ere is no supported feature making use of this input however this will be expanded in future firmware updates Advanced Configuration Several gateway and port properties may only be altered using Pathscape software available on the Pathway website www pathwayconnect com Please refer to the Pathscape manual for information on these values and how to set them Firmware upgrades may only be done using ...

Страница 14: ...information Power input 90 260 VAC 50 60 Hz Max current consumption 0 75 A 1000V isolation between all ports 250V protection on all ports Compliance USITT DMX512 1990 ANSI E1 11 DMX512 A R2013 E1 20 RDM Remote Device Management E1 31 sACN Streaming ACN ETL RoHS 2002 95 EC ...

Отзывы: