background image

14212650-IG, Edition 1.0
April 2018, Original document

19

Installing Multiple Spectralink IP-DECT Server 200s in
Large Areas (2)

Large areas defined as: radius larger than 30 meters/100 feet; 30 meters/100-feet cells overlap.

The image below shows overlapping cells supporting up to 5 base units (total).

Users can talk within their own 30 meters/100-feet radius cells. Users from both cells can talk in the
common (overlapping) area. Cells on adjacent floors can also overlap.

1. Follow the previous instructions for installing multiple base units and select the optimal loc-

ations for up to 5 base units.

2. Where the 30 meters/100 feet radius cells overlap, then the maximum number of base units

installed in the area that overlaps must be 5 or fewer to avoid any interference. This includes
where adjacent floors may overlap.

Spectralink IP-DECT Server 200 Deployment and Installation Guide

Summary of Contents for K005

Page 1: ...14212650 IG Edition 1 0 April 2018 Original document Spectralink IP DECT Server 200 Deployment and Installation Guide ...

Page 2: ...operty of Spectralink and shall be neither reproduced in whole or in part without the prior written approval of Spectralink nor be implied to grant any license to make use or sell equipment manufactured in accordance herewith Spectralink reserves the right to make changes in specifications and other information contained in this document without prior notice and the reader should in all cases cons...

Page 3: ...our Handsets and Spectralink IP DECT Server 200 for Installation 11 Find the Best Installation Locations 12 Wall Mount and Power on the Spectralink IP DECT Server 200 13 Different Installation Use Cases 15 Installing a Single Spectralink IP DECT Server 200 in a Small Area 15 Installing Multiple Spectralink IP DECT Server 200 in a Small Area 16 Installing Single Spectralink IP DECT Server 200s in L...

Page 4: ...P DECT Server can be done using the following 3 methods l DHCP Option pointing to enterprise own Provisioning Server l Manual configuration l Configuration done by service provider when deployed with UCaaS platforms It is assumed that your handsets have been registered to the system so that you can subscribe each handset using an activation code if needed 14212650 IG Edition 1 0 April 2018 Origina...

Page 5: ...about provisioning refer to the guide available online at http sup port spectralink com products Spectralink Technical Bulletins Available online at http sup port spectralink com products Release Notes Document that describes software changes bug fixes outstanding issues and hardware compatibility con siderations for new software releases Available online at http support spectralink com products S...

Page 6: ...ports up to 12 registered handsets and 6 sim ultaneous calls The DECT radius of coverage is up to 600 meters 2000 feet with a handset in free sight Power Requirements for the Spectralink IP DECT Server 200 l Power over Ethernet PoE 802 3af l Maximum power supply consumption is 3 0W IEEE 802 3af class 1 device Use a standard PoE adapter or a PoE enabled port on an ethernet switch adhering to PoE 80...

Page 7: ...escription of the Spectralink IP DECT Server 200 appearance and com ponents Spectralink IP DECT Server 200 bottom Spectralink IP DECT Server 200 rear 1 Reset button 2 DC 3 LINK ActivityIndicator 4 ETH port power supplybyPoE 1 Holesfor wallmounted screws 2 Connection to LAN Spectralink IP DECT Server 200 Deployment and Installation Guide ...

Page 8: ...erver The following table contains a description of the different actions that take place when pressing the Reset button Press button Action Short press 2 to 5 sec System restarts when button is released Long press 5 to 9 sec until front LED flashes red then release button Resets the system to factory default settings original IP settings DHCP and restarts the system Firmware ver sion is not affec...

Page 9: ... The indicator is on when the server is operating LED Indicator Meaning Steady green OK and idle Slow green flashing OK and active voice call Fast green flashing Busy all channels are in use Steady red Reset shutdown in progress Steady red for 5 seconds followed by fast red flashing Reset to factory settings Red flashing Error or rebooting LAN Port on Face Plate LED Indicator Meaning LINK Indicato...

Page 10: ...00 on your virtual PBX This will ensure you receive correct activation codes that link your handset accounts with your Spectralink IP DECT Server 200s when you order 3 Within the same 30 meters 100 feet radius you can install up to 5 Spectralink IP DECT Server 200s Example 5 Spectralink IP DECT Server 200s in the same 30 meters 100 feet radius support up to 20 simultaneous calls and up to 30 hands...

Page 11: ...nd Spectralink IP DECT Server 200 LED Indicators on page 9 3 Subscribe the new handsets to the server s Also if needed ensure that you have the activ ation codes for the handsets ready For more information about subscribing the handset and creating Login see Handset User Guides 4 Before physically installing the Spectralink IP DECT Server 200 onto walls l Place the Spectralink IP DECT Server 200s ...

Page 12: ...r Depending on the type of product bundle ordered the AC power supply for the IP DECT Server 200 may be included 3 Verify with the end users where coverage is needed so the Spectralink IP DECT Server 200 can be placed near center of the 75 meters 245 feet radius where users are normally situated Tip Also identify areas where coverage is not required to simplify the installation 4 Spectralink IP DE...

Page 13: ...ink IP DECT Server 200 on the wall using the anchors and screws accom panying the product Note When you place the Spectralink IP DECT Server 200 on the screws ensure that the screws do not touch the printed circuit board 1 Holesfor wallmounted screws 2 RJ45 port 2 Connect the RJ45 plug to the ethernet connector at the bottom of the Spectralink IP DECT Server 200 Spectralink IP DECT Server 200 Depl...

Page 14: ...14212650 IG Edition 1 0 April 2018 Original document 14 3 After installing the Spectralink IP DECT Server 200 you need to power it up Spectralink IP DECT Server 200 Deployment and Installation Guide ...

Page 15: ... Spectralink IP DECT Server 200 within a 30 meter 100 feet radius cell that contains the users and the areas where they are situated 2 If the coverage area has multiple floors or goes across heavy walls the Spectralink IP DECT Server 200 s range may be limited to 15 meter 50 feet or less for the floor above or across the heavy walls Test the Spectralink IP DECT Server 200s range and call quality b...

Page 16: ...out 0 6 meters 2 feet apart from each other but place all near the center of the cell as in the diagram above 2 In coverage areas with multiple floors or heavy walls the Spectralink IP DECT Server 200s range may be limited to 15 meters 50 feet or less for the floors above or across the heavy walls Test the Spectralink IP DECT Server 200s range and call quality before permanently installing them l ...

Page 17: ...Spectralink IP DECT Server 200 in each The image below shows 2 independent cells over 30 meters 100 feet apart with 1 Spectralink IP DECT Server 200 in each 1 Follow the previous instructions and select the optimal location for each Spectralink IP DECT Server 200 within its own 30 meters 100 feet radius cell 2 The cells in this configuration do not overlap which means each Spectralink IP DECT Serv...

Page 18: ...ectralink IP DECT Server 200s and select the optimal locations for up to 5 Spectralink IP DECT Server 200s 2 If each cell has a 30 meters 100 feet radius that does not overlap with adjacent cells then each Spectralink IP DECT Server 200 can be installed and will operate independently 3 If the 30 meters 100 feet radius cells overlap then the maximum number of Spectralink IP DECT Server 200s install...

Page 19: ... 100 feet radius cells Users from both cells can talk in the common overlapping area Cells on adjacent floors can also overlap 1 Follow the previous instructions for installing multiple base units and select the optimal loc ations for up to 5 base units 2 Where the 30 meters 100 feet radius cells overlap then the maximum number of base units installed in the area that overlaps must be 5 or fewer t...

Page 20: ...or external antenna K018B 0244 0000 Spectralink DECT Repeater 1G9 2 channels with connector for external antenna K018B 0244 1000 Spectralink DECT Repeater 1G8 2 channels without connector for external antenna K018 0244 1100 Spectralink DECT Repeater 1G9 2 channels without connector for external antenna K018 0244 1200 Spectralink DECT Repeater 1G8 4 channels with connector for external antenna K018...

Page 21: ... 2018 Original document 21 Spectralink Server Licenses for 200 Lync SfB Security TLS SRTP IP DECT Server 200 1407 5511 Security TLS SRTP IP DECT Server 200 1407 5281 Spectralink IP DECT Server 200 Deployment and Installation Guide ...