Tube

adapter end

1.  Tilting of the flange may lead to the leakage of breastmilk. Please sit up straight while 

pumping to ensure the flange does not tilt.

2. It is important to find the maximum vacuum level that is comfortable for you, as 

pumping at an uncomfortably high vacuum level may cause pain and hinder your 

milk flow.

3. To determine your own maximum vacuum level, use the vacuum level and cycle 

speed controller buttons on the breast pump to increase the intensity until pumping 

feels slightly uncomfortable (not painful), then decrease the intensity slightly.

4. On average, a typical expressing session goes for 10-15 minutes, but this is just a guide 

and may vary for each individual.

5. Upon completion of pumping, do not just pull away the flange in its sealed state, but 

instead turn off the power first and remove the flange slowly by breaking the seal 

between your breast and the flange with your finger.

1.  Disassemble and wash all parts that come in contact with breastmilk immediately 

after use according to the instructions in the user manual using bottle washing 

detergent and appropriately shaped bottle brush and rinse under running water.

2. The general practice is to sterilize the washed parts in boiling water for 5 minutes.
3. After washing and sterilizing, ensure all parts are completely dry and store in a 

container or clean space.

4. Replace any worn out or scratched consumable parts.

Storage and care after use

Safety precautions

1.  Persons with reduced physical, sensory or mental capabilities, or lack of experience 

and knowledge, should not use the product unless they have been given supervision 

or instruction by a person responsible for their safety.

2. Children should be supervised to ensure that they do not play with the product.
3. Always inspect the product components for signs of damage before each use.
4. Use only genuine original Spectra accessories and parts.
5. Wash (do not use antibacterial or abrasive cleaners/detergents) and sterilize all 

product parts before each use.

6. Avoid exposure to high heat and direct sunlight.
7. Never use while pregnant, as pumping can induce labor.
8. This product is a personal care item that should be used by a single user. Use of the 

product under second-hand or rental conditions carries the risk of 

cross-contamination between multiple users and requires caution.

9. Some discomfort may be felt when first using a breast pump, however, if you should 

continue to feel pain, or if tearing or bleeding occurs around your nipples, you should 

immediately seek medical advice.

How to use

  Should milk backflow during pumping, stop the pump operation immediately and remove any milk 

first, then check all consumable parts for damage / connection condition. If you suspect that the 

milk has backflowed into the main pump unit, stop using the pump immediately and asses the unit 

before using again.

Summary of Contents for CaraCups

Page 1: ...CaraCups User Manual Breast Pump Accessory...

Page 2: ...raCups for the first time This is a single user accessory and therefore should not be used by more than one individual Sharing CaraCups among multiple users may present a health risk Spectra CaraCups...

Page 3: ...tain in a hygienic manner as this product comes in direct contact with breastmilk CaraCups features CaraCups components How to clean Usage instructions Preparation before use How to use Storage and ca...

Page 4: ...tibility with Spectra Breast Pump products Effective Pumping You can save time at home by pumping while breastfeeding You can pump in the office with your clothes on as CaraCups fit into your bra You...

Page 5: ...ater for 2 minutes after washing with baby bottle cleansing detergent 3 Keep away from abrasives and excessive heat and handle all parts with care 4 Store away from reach of babies and children when n...

Page 6: ...iner or clean space 4 Replace any worn out or scratched consumable parts Storage and care after use Safety precautions 1 Persons with reduced physical sensory or mental capabilities or lack of experie...

Page 7: ...ssembly 1 Prepare the valve connector membrane and backflow prevention cap 2 Assemble in the order of valve connector membrane and backflow prevention cap 3 Align the flange to the assembled valve con...

Page 8: ...hod by using the additional accessories You can use the existing Spectra wide neck bottles If you don t have Spectra wide neck bottles they can be purchased separately Ensure the tubing connector is f...

Page 9: ...ump Spectra CaraCups are compatible with all Spectra Baby USA electric breast pump models Spectra CaraCups are not compatible with the manual and piston type breast pumps CaraCups pump mode Tube adapt...

Page 10: ...ow CaraCups to slip sag down or tilt sideways during use 3 Check that the flanges are sealed tight onto your skin 5 Tilting of the flange may lead to leaking of breastmilk Please pump sitting upright...

Page 11: ...off 2 Carefully remove the tubing while still keeping CaraCups on in place Grabbing the milk collection cup with force may create a gap between the flange and the milk collection cup causing the breas...

Page 12: ...93 www spectrababyusa com If you need help with your Spectra product our customer support team members are here to happily answer any questions Product Support Phone 1 855 405 0993 Email customercare...

Reviews: