Testing the system 

 

Normally no adjustment is necessary as the unit has been set up at the factory for your water-
maker, however it is advisable to make sure it is working properly. You will need Spectra test 
kit #

EL-ZION-TESTKIT. 

  Once the installation is complete and the unit is powered up activate the 

FW flush by pushing the auto store button on the MPC controller once. If you have a Ventura 
Deluxe initiate a manual flush cycle.  The LED on the Z-ION controller should start flashing as 
the unit cycles. Close to the end of the flush cycle, take a sample of the brine discharge. If the 
discharge thru hull isn't accessible you will need to use the brine discharge service hose to gain 
access to the system. Once you have obtained a sample, first  check it with a salinity monitor to 
make sure the salinity is below 1000 PPM. Next, use the copper test kit to make sure that there 
is at least 1 PPM of copper in the flush water. This will also insure that there is adequate silver 
in the mix to kill the bacteria. 
 

If the flush water is above 1000 PPM or does not have adequate copper content then please 
contact our technical support for instructions on how to adjust the system. 

Summary of Contents for Z-Ion

Page 1: ...ion and Retrofit Instructions Ventura Deluxe and MPC 5000 versions Spectra Watermakers Inc 20 Mariposa Road San Rafael CA 94901 Phone 415 526 2780 Fax 415 526 2787 www spectrawatermakers com Rev 06 13...

Page 2: ...Making Fresh Water World Wide...

Page 3: ...shing external power sources pickling chemicals or complex procedures The whole operation is completely automatic controlled by the Z ION circuit When properly installed and maintained it will protect...

Page 4: ...and ensure warranty coverage Turn off the domestic fresh water pump and bleed any re maining pressure in the pipes Locate Ventura feed pump module Disconnect the inlet hose Remove the inlet hose barb...

Page 5: ...lter bowl and replace with the Z ION generator bowl Mount the control box on the bulkhead adjacent to the feed pump module shown just above the filter bowl Plug the Z ION connector from the generator...

Page 6: ...Locate the DC Bus Bar as shown below which is the main power feed for the watermaker Incoming DC Bus Bar Connect the DC power leads from the Z Ion Control Box to the Incoming DC Bus Bar Pay attention...

Page 7: ...as the unit cycles Close to the end of the flush cycle take a sample of the brine discharge If the discharge thru hull isn t accessible you will need to use the brine discharge service hose to gain ac...

Page 8: ...0 48 VDC inlet voltage 10 38V output 1 5A Current controlled Polarity reverses every 10 15 seconds adjustable Timed auto shutoff adjustable Current output is field adjustable Operation The unit can ha...

Reviews: