44
Warning!
The rates of message types RNX (ATOM message
type) and MPC (Ashtech legacy message type) are in fact
defined by the
Recording Interval
parameter on the
Sessions
-
Scheduling
web page (see
). The value you might enter on the
Raw Data
web
page for these messages would anyway be ignored. It
would even be overwritten with the value given to
Recording Interval
when the first session starts.
•
Click on the
Configure
button to save all the changes
made. The concatenation of the selected messages will
constitute the G-files saved in the receiver (internal
memory or USB device).
Programming
Sessions
The typical use of sessions in a CORS station consists of
defining 24 sessions representing each one-hour data
recording at a 1-second recording interval. Follow the
instructions below to create these sessions:
•
Click on
Sessions
-
Scheduling
.
•
Enter “00:00:00” as the
Start Time
, “1” as the
Recording
Interval
, “01:00” as the
Duration
and “24” as the
Number
of Sessions
.
•
Click on the
Auto Set
button.
•
Click on
Back
after the “Successful” message has been
returned b the Web Server. You can now see the list of
sessions you have just created in the Sessions table: