75
-
Suspicious Object
Suspicious Object is including the object missing or the doubtful object appears on the screen.
Click
OK
to save and exit the setup windows. To exam the setup condition, click
Start Test
.
1.
Select the camera number (0-16) and press right button on the mouse to call up the
setup windows. And then, click the
Suspicious Object
Tab.
2. Click
Save
to capture the image for comparing reference. To view the captured image,
enable the
Show Reference Image
check box. The captured image will display on
screen. The reference image is sharing with the Missing Object and Scene Change
function.
3. Mark
the
Enable
check box to setup the condition.
4.
Sensitive:
Set the system detects sensitivity.
5.
Delay Time:
Set the lasting time for system to detect the object.
6.
Use the mouse to click and drag the frame on the screen.
•
Maximum_Object:
the maximum detect size. The objects are out of the
maximum detect area will be disregard. Use mouse to click and drag the frame on
the screen.
•
Minimum_Object:
the minimum detect area. When the objects are smaller than
the minimum detect area, the system will disregard. Use mouse to click and drag
the frame on the screen.
7.
Enable Mask
Mark an area on the screen to disregards the motion in the marked area and to only
monitor outside the marked area. Mark the
Enable Mask
check box, click and drag
the mask frame on the screen.
8.
To reset all object frames, click
Clean
. To clean an object frame, click right button of
mouse and drag the object frame that user want to clean