Fig. 2
Template for Installation in Gunite or Concrete Pools.
B
ADU
S
TREAM
II
in Concrete or Gunite Pool.
4. Concrete or Gunite Installation
5
A.
Preplumb
B
ADU
S
TREAM
II
Housings.
1. Install plumbing manifold or approximately 12" of 4"
SCH 40 pipe to both suction and discharge fittings on
the jet(s) housing. NOTE: If plumbing exceeds 30'
between jet housing and pump, increase pipe size to
6". Install a 6x4" reducing bushing as close to jet
housing as possible.
1. Locate air control hose connector (part #6) at the
top and center of jet housing. Air control hose
connectors must be vertical or the square cover will
be uneven in appearance.
C.
Place jet housing into reinforced steel. Jet housing
location is very important.
B.
Tape jet housing. Keep concrete out of threaded
inserts and out of the inside of the housing.
2. Install air control PVC hose to hose socket insert
fittings (part # 6). Use hose clamps to secure hose to
insert fitting.
2. The center of the housing (the nozzle) should be
10" BELOW water level for maximum efficiency.
3. Front edge of jet housing should finish even with
inside gunite wall. Make sure a V shaped groove is
scraped out around the housing approximately 1 1/2"
deep to allow marcite to seal against the housing.
4. Recheck location of the jet housing when gunite is
being applied. The force of the gunite may move the
jet location.
5. To avoid stress on the jet housing, we recommend
that the
B
ADU
S
TREAM
II
housing be encased with
gunite and at least 2 to 3 inches of the plumbing stub
out is covered with gunite.
NOTE: Stress on the
plumbing may crack the
B
ADU
S
TREAM
II
housing.
D.
Air regulator installation should be approximately
4" ABOVE the water level.
1. Air regulator holder and hose socket insert fitting
connect to PVC hose. Make sure air regulator holder
face is tapped over to prevent gunite from entering
holder.
2. Air regulator can be located in the tile line above
water line or in the deck.
E. Keep all parts not being used now in original box.
Store in a safe place until needed.
An extension ring is available (upon request) for an
application that has special needs.
Air Regulator
2" Minimum
10"
Plaster
Suction
Pipe
Fitting 4"
45 Elbow
Fitting 4"
Concrete
Wall
Housing
Water Level
Air Line
Tile
Deck
Pressure
2" Minimum
10"
Nozzle
Water Level
Air Regulator
®
Fig. 3