Fig. 2

Template for Installation in Gunite or Concrete Pools.

B

ADU 

S

TREAM

 

II

 in Concrete or Gunite Pool.

4. Concrete or Gunite Installation

5

A.

 Preplumb 

B

ADU

S

TREAM

 

II

 Housings.

1. Install plumbing manifold or approximately 12" of 4" 
SCH 40 pipe to both suction and discharge fittings on 
the  jet(s)  housing.  NOTE:  If  plumbing  exceeds  30' 
between jet housing and pump, increase pipe size to 
6".  Install  a  6x4"  reducing  bushing  as  close  to  jet 
housing as possible.

1.  Locate  air  control  hose  connector  (part  #6)  at  the 
top  and  center  of  jet  housing.  Air  control  hose 
connectors  must  be  vertical  or  the  square  cover  will 
be uneven in appearance.

C.

 Place jet housing into reinforced steel. Jet housing 

location is very important.

B.

  Tape  jet  housing.  Keep  concrete  out  of  threaded 

inserts and out of the inside of the housing.

2.  Install  air  control  PVC  hose  to  hose  socket  insert 
fittings (part # 6). Use hose clamps to secure hose to 
insert fitting.

2.  The  center  of  the  housing  (the  nozzle)  should  be 
10" BELOW water level for maximum efficiency.

3.  Front  edge  of  jet  housing  should  finish  even  with 
inside  gunite  wall.  Make  sure  a  V  shaped  groove  is 
scraped out around the housing approximately 1 1/2" 
deep to allow marcite to seal against the housing.

4. Recheck location of the jet housing when gunite is 
being applied. The force of the gunite may move the 
jet location.

5. To avoid stress on the jet housing, we recommend 
that the 

B

ADU

S

TREAM

 

II

 housing be encased with 

gunite and at least 2 to 3 inches of the plumbing stub 
out  is  covered  with  gunite. 

NOTE:  Stress  on  the 

plumbing  may  crack  the 

B

ADU

S

TREAM

 

II 

housing.

D.

  Air  regulator  installation  should  be  approximately 

4" ABOVE the water level.

1.  Air  regulator  holder  and  hose  socket  insert  fitting 
connect to PVC hose. Make sure air regulator holder 
face  is  tapped  over  to  prevent  gunite  from  entering 
holder.

2.  Air  regulator  can  be  located  in  the  tile  line  above 
water line or in the deck.

E. Keep all parts not being used now in original box. 
Store in a safe place until needed.

An  extension  ring  is  available  (upon  request)  for  an 
application that has special needs.

Air Regulator

2" Minimum

10"

Plaster

Suction

Pipe

Fitting 4" 

45    Elbow

Fitting 4" 

Concrete 
  Wall

Housing

Water Level

Air Line

Tile

Deck

Pressure

2" Minimum

10"

Nozzle

Water Level

Air Regulator

®

Fig. 3

Summary of Contents for BADUSTREAM II

Page 1: ...ction Optional Round C Adjustable Water Flow Jet Nozzle D Air Regulator adjusts amount of air bubbles in water flow E Control Box with GFCI with pneumatic button and tubing G Optional Massage Hose wit...

Page 2: ...4 4 Concrete or Gunite Installation Page 5 5 Liner and or Fiberglass Pool Installation Page 6 5a Removal of Liner Page 7 6 Plumbing Suggestions Page 8 9 7 Installation of the Pump and the Control Box...

Page 3: ...USTREAM II is complete with jet housing 4 HP or 3 5 HP pump control box and optional massage hose The only additional requirement is the plumbing 4 pipe for 4 HP and 3 pipe for 3 HP units G DO NOT sto...

Page 4: ...on pump model 98 The air regulator assembly hardware is US standard thread The center of the housing the nozzle should be 10 BELOW water level for maximum efficiency The air regulator should be appro...

Page 5: ...ousing should finish even with inside gunite wall Make sure a V shaped groove is scraped out around the housing approximately 1 1 2 deep to allow marcite to seal against the housing 4 Recheck location...

Page 6: ...to mark and drill the holes as shown in Fig 4 For the air regulator one 1 2 hole must be provided preferably along the vertical axis approximately 4 ABOVE the water line For Liner pools only two holes...

Page 7: ...g from the wall NOTE If the two counter sunk bolts part 27 which hold the jet housing to the wall were installed the jet housing should not move and the two remaining bolts can be removed Remove one o...

Page 8: ...nstallation 4 Elbow 4 Elbow 45 4 Pipe 4 Elbow 4 Pipe 4 Pipe 4 Pipe 10 to 18 NOTE Increase pipe size to 6 when jets are more than 30 feet from pump Use 6 x 4 bushings after 4 manifold tees 4 Elbow 45 4...

Page 9: ...trical Code Article 680 22 the pump motor must be electrically bonded to the pool structure reinforced bars etc by a solid copper conductor not smaller than No 8 AWG via the external copper bonding lu...

Page 10: ...the massage hose with pulsator unless they are closely supervised at all times Close air regulator Reduce the volume of water by turning the adjustable flow nozzle s clockwise Under certain conditions...

Page 11: ...5 1 Hose 8 x 3 16 2 Hose Clamp 14 9 17 1 Holder Air Regulator 18 2 Bolt 1 4 20 x 1 1 2 19 2 Nut 1 4 20 20 2 21 1 Gasket 60 x 11 x 2 22 26 1 Subassembly Complete 22 1 Top Part Air Regulator 23 1 Bottom...

Page 12: ...hall notify Speck Pumps of such claim by telephone or by mail After the customer has been authorized to return a defective BADUSTREAM II the customer must return the BADUSTREAM II to Speck Pumps Any g...

Reviews: