Speck pumpen V 130 Assembly Instructions Manual Download Page 4

Assembly Instructions V 30 - 430 

 

Speck Pumpen Vakuumtechnik GmbH 

zertifiziert: DIN EN ISO 9001

 

1.2 

Disassembling Impeller  

  Block the impeller (230) at shaft seal housing (441) 

  Remove fixed hexagon nut from impeller adjusting screw 

  Remove impeller (230) from shaft   

  Remove impeller screw (906) and distance springs (950) from shaft. Notice position of distance 

springs 

1.3 

Disassembling Shaft Seal Housing  

  Remove fixed hexagon nut or hexagon head cap screw at motor flange  

  Remove shaft seal housing from motor flange 

1.4 

Disassembling Mechanical Seal   

  Turn  around shaft seal housing 

  Press mechanical seal out of seat at shaft seal housing (back side)  

  Remove rotating part of mechanical seal at impeller 

 

Summary of Contents for V 130

Page 1: ...Speck Pumpen Vakuumtechnik GmbH zertifiziert DIN EN ISO 9001 Assembly Instructions V 30 430...

Page 2: ...assembling Shaft Seal Housing 4 1 4 Disassembling Mechanical Seal 4 2 REASSEMBLING PUMP 5 2 1 Reassembling Mechanical Seal 5 2 1 1 Rotating part of Mechanical Seal 5 2 1 2 Standstill part of Mechanica...

Page 3: ...reassembly of the pump Special Tools Parts and Materials Feeler gauge Molykote G n Paste or equivalent Liquid sealing e g Epple 32 Metal straightedge Loctite 242 and Primer Solvent such as kerosene 1...

Page 4: ...30 from shaft Remove impeller screw 906 and distance springs 950 from shaft Notice position of distance springs 1 3 Disassembling Shaft Seal Housing Remove fixed hexagon nut or hexagon head cap screw...

Page 5: ...rust at seat for mchanical seal 2 1 Reassembling Mechanical Seal 2 1 1 Rotating part of Mechanical Seal Coat the O ring of mechanical seal with thin bodied oil Move mechanical seal 047 over the shaft...

Page 6: ...usting screw 906 Be carefull because the distance springs should be mounted as shown in the picture above Coat the thread of impeller adjusting screw also with molykote Tread in the impeller adjusting...

Page 7: ...surface of the impeller and the surface of the shaft seal housing Use the metal straightedge and the feeler gauge to adjust the gap Block the impeller if the gap is correct Tighten nut of the impelle...

Page 8: ...skets 2 6 Reassembling Pump Case and Inter Casing Type V 95 130 155 255 330 430 Install O Ring 412 at pump casing Install inter casing at pump casing Correct position is given through the pin of pump...

Page 9: ...Kerbstift grooved pin 598 Blech sheet 746 Klappe flap 800 Motor motor 900 Schraube screw 901 6kt Schraube hexagon head cap screw 901 1 6kt Schraube hexagon head cap screw 901 2 6kt Schraube hexagon h...

Page 10: ...Mounting Instructions V 30 430 Edition 02 03 Address Speck Pumpen Vakuumtechnik GmbH Regensburger Ring 6 D 91154 Roth Phone 49 09171 809 0 Fax 49 09171 809 10 e mail info speck pumps de internet http...