Installation
22
English
5
Installation
5.1 Mechanical installation
Installation site
Provide a weatherproof, frost-free, dust-free and
well-ventilated room for the installation. Choose
an installation site that is easily accessible.
1.
Prepare the installation site so that the pump
can be installed without being exposed to
mechanical stresses.
2.
Choose the right installation position - only as
shown in (Fig. A).
The arrow on the back of the housing indi-
cates the direction of flow.
Turn the motor head or
remove it
3.
Release the union nut - unscrew it completely
if necessary.
4.
Turn the motor head so that the electrical
connector points downwards.
5.
Tighten the union nut again.
Danger:
Before starting work, make sure
that the pump has been disconnected from the
power supply.
Caution:
Dirt can cause the pump to fail.
Flush the pipe system before installation.
Caution:
Do not damage the housing seal.
Replace damaged seals.
Caution:
If the position is wrong, water
can penetrate and destroy the pump.