MASTERMIND TCU - ERROR CODES & FACTORY RESET
MasterMind TCU equipped models have a built-in diagnostic system to automatically check and identify the functionality of the system. If the
system detects an error, the MasterMind TCU will show the error on the display. In some cases, the error message can be dismissed by pushing
any button on the remote.
Depending on the type of error message, the system may be switched off automatically. If you receive an error message, please restart the
system. If the error message continues to display, please contact your Authorized Specialized Retailer for further instructions. In any case, the
bicycle can be ridden without motor support with the system turned off.
Mission Control supports the rider with User Actions for errors and diagnostic reports which can be shared with retailers who
can give further advice based on the bicycle serial number.
MASTERMIND TCU RESET PROCESS:
Standard Reset
Standard reset is the first troubleshooting step if an odd bike or display behavior occurs, such as failing to connect to MC after a previously
successful connection.
Standard reset restores the default Tune settings, including Acceleration Response and Shuttle.
Dual press and hold the (+) and (-) buttons for 20 seconds.
Release the buttons when the MasterMind TCU reboots.
Factory Reset
A factory reset should be performed before a new or used bicycle is handed over to a new rider. Factory Reset restores the system to factory
Settings, also clearing and resetting previous BLE pairings.
Dual press and hold the (+) and (-)buttons for 45 seconds. During this process, the MasterMind TCU will reboot twice.
Release the buttons when the MasterMind TCU reboots for the second time.