4
Place Rubber Washers (1) on inlets of Valve
Body and position body assembly up to Swivels
and tighten Coupling Nuts.
NOTE: Shower Arm Strap location optional.
Disconnect assembly from supply lines.
5
MOUNTING AND INSTALLATION OF ASSEMBLY WITH FLANGE
Verify that the mounting location and structure is capable of supporting
the product in use.
Hold assembly up against wall and mark location of mounting holes for
Valve Body (1) and Shower Arm Strap (2) referencing the rough-in
diagram contained in this document.
Drill starter holes at marked locations
Connect Valve Assembly (1) to Supply Lines (2) and tighten Coupling Nuts (3) with
wrench. Fasten body and strap to wall using four (4) Mounting Screws provided.
6
MOUNTING AND INSTALLATION OF ASSEMBLY WITH LUGS
Verify that the mounting location and structure is capable of supporting
the product in use.
Hold assembly up against wall and mark location of mounting holes for
Valve Body (1) and Shower Arm Strap (2) referencing the rough-in
diagram contained in this document.
Drill starter holes at marked locations
Connect Valve Assembly (1) to Supply Lines (2) and tighten Coupling Nuts (3) with
wrench. Fasten body and strap to wall using four (4) Mounting Screws provided.
7
Turn water supplies on and flush both Hot and
Cold sides of fitting.