background image

FEATURE DESCRIPTIONS 

(Refer to Fig. 1)

1. Spring-loaded 

EZ-Connect Terminals

accept wire sizes 14 to 28

AWG for connection of the following:  

• 

+12V DC

– Powers connected IR Receivers, Keypads, etc.  

• 

GND

– Return for Power, IR signal and Status indicators

• 

ST OUT

– Connects status voltage to Status Indicators in 

IR Receivers, Keypads, etc. 

• 

IR IN

– Receives IR control signals from IR Receivers, 

Keypads, etc.

2. 

Mounting Holes

– Attaches the AT-1.0 to any flat surface using

the two screws provided.  

3. 

EMITTERS

– Two 3.5mm jacks drive two emitters at medium

power. 

4. 

EMITTERS/BLASTERS

– Two 3.5mm jacks drive two emitters at

medium power or two blasters at very high power.

Sp

e

a

k

e

rC

ra

ft

®

AT-1.0

Amplified Terminator

SmartPath

INSTALLATION INSTRUCTIONS

Fig. 1

The AT-1.0 provides a convenient means of interconnecting
SpeakerCraft (and industry compatible) IR products in IR repeating
systems. It includes a wide bandwidth amplifier for robust operation.
It has blaster drive power capability and is reverse voltage protected.

J4

J7

J6

J5

J8

+12V

GND

ST OUT

IR IN

IR

RCVR

STATUS IN

5~24V DC

12V DC

REGULATED

BL ON
BL ON
NET ON

EM ON
EM ON

EMITTERS /

BLASTERS

EMITTERS

NET OFF

AT-1.0

AMPLIFIED

TERMINATOR

SpeakerCraft

1

2

3

4

5

2

6

7

8

®

2

5. 

DIP Switch (3 position)

– The upper two positions switch between

emitter power (EM ON) and blaster power (BL ON) for the two corre-
sponding EMITTERS/BLASTERS jacks.  

CAUTION:

The BL ON position sets the AT-1.0 to very high blaster

power. Be sure to return the DIP switch to Emitter On (EM ON)
position when driving normal emitters. 

Failure to do so will

smoke the emitters!

Network Terminator

. The bottom DIP position allows the IR IN and

IR RCVR inputs to be terminated with a 500

resistor (NET ON), or

un-terminated (NET OFF). The NET ON position should be chosen
when using long lengths of wire (over 50', shielded in particular)
between the IR receiver, keypad, etc. and the AT-1.0. This ensures
best operation for high data rate IR codes. If using two or more
AT-1.0’s in a paralleled network system 

(see Fig. 4)

, be sure 

only

ONE

of the AT-1.0 Terminators is set to the NET ON position. 

6. 

12V DC REGULATED

– 2.1mm jack, center pin +, accepts 12V DC

regulated power supplies to power the IR system. Calculate the current
required, then use SpeakerCraft power supplies PS-1.0 (200 mA) or PS-2.0
(1.2 A). 

Note:

The “no signal” current draw of the AT-1.0 is zero.

7. 

STATUS IN 5-24V DC

- 2.1mm jack, center pin +, accepts 5V through

24V DC power supplies to power system ON/OFF Status Indicators of
connected IR receivers, keypads, etc.

8.

IR RCVR

– Exclusive four-circuit 3.5mm jack provides connection for

SpeakerCraft direct plug-in IR Receivers. Connections are made, not only
for Power, Signal and Ground, but for the Status Indicator in the IR
Receivers as well.    

SYSTEM CONNECTIONS

The following are a few typical applications of the AT-1.0 for IR repeater
systems.

A Basic System

Fig. 2

shows a basic installation, such as controlling components that are

behind closed cabinet doors. 

To 120V AC 

(unswitched)

PS-1.0

Power
Supply

A/V Receiver

Satellite

DVD

AT-1.0

Amplified Terminator

IRC-3.0

Shelf Top

IR Receiver

IRE-3.0

 

 Visible Emitter

IRE-3.0

  Visible Emitter

IRE-3.0

Visible Emitter

Remote Control

J4

J7

J6

J5

J8

+12V

GND

ST OUT

IR IN

IR

RCVR

STATUS IN

5~24V DC

12V DC

REGULATED

BL ON
BL ON
NET ON

EM ON
EM ON

EMITTERS /

BLASTERS

EMITTERS

NET OFF

AT-1.0

AMPLIFIED

TERMINATOR

SpeakerCraft

®

Fig. 2

3

1. Plug in the IR Receiver and Emitters as shown. 

Note:

Since the AT-1.0 employs emitter current sharing, you may use

any of the IRE-1.0, 2.0, 3.0, or 4.0 SpeakerCraft emitters in any
combination you wish. 

2. Set the DIP switches to EM ON and NET ON or NET OFF.
3. Plug in the Power Supply.
4. The AT-1.0 system should now control the components.

A Multi-Room System

Fig. 3

is an example of a multi-room (not multi-zone) system. SpeakerCraft IR

receivers in each room, plus a local IR receiver, control the various compo-
nents in the main room or equipment area.  

To 120V AC 

(unswitched)

PS-1.0

Power
Supply

IR OUT

ST IN

GND

+12V

IRC-4.0

J-BOX

IR RECEIVER

SpeakerCraft

A/V Receiver

Satellite

DVD

AT-1.0

Amplified Terminator

IRC-4.0

J-Box IR Receiver

IRC-2.0

Surface Mount IR Receiver

IRC-1.1

Flush Mount IR Receiver

IRC-3.0

Shelf Top IR Receiver

IRE-1.0

 

Emitter

IRE-3.0

  Visible Emitter

ROOM 1 

ROOM 2 

ROOM 3 

PS-1.0

"STATUS"
 Supply

To Switched
AC Outlet on
A/V Receiver

IRE-4.0

  Dual

 Visible Emitter

To Additional
Controlled Unit

CONTROLLED COMPONENTS AREA, MAIN ROOM, ETC.

Rear View

Add Resistor at each IR receiver
to reduce STATUS brightness,
if desired. See text.

Striped

Side

STATUS

+12V

GND

IR OUT

STATUS

(yellow)

+12V

(red)

GND

(black)

IR OUT

(white)

+12V

GND

ST OUT

IR IN

IR

RCVR

STATUS IN

5~24V DC

12V DC

REGULATED

BL ON
BL ON
NET ON

EM ON
EM ON

EMITTERS /

BLASTERS

EMITTERS

NET OFF

AT-1.0

AMPLIFIED

TERMINATOR

SpeakerCraft

EZ-Connect Terminals

®

®

Fig. 3

Reviews: