background image

16

IOM 81, Issue 2 - Modulo Thermostat

7. Appendix 1

7.1 Setting Up Menu Lock

The password can be reset via use of the master password: 

[CALEON]

(square brackets and capitals required).

Menu lock

Protect settings

with a password

Yes

No

Step 2

Click on the ‘yes’ icon.

Expert

Select language

Date & Time

Settings

Service values

Menu lock

Factory settings

Step 1

To set up the menu 

lock, go into the expert 

section. Click on the 

‘menu lock’.

Enter password

****E

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

abc 123 !#@

Step 3

Enter password.

Then click on the arrow.

Confirm password

****E

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

abc 123 !#@

Step 4

Re-enter password to 

confi rm. Then click on

the arrow.

Enter password

****E

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

abc 123 !#@

Step 7

Enter the password

to remove menu lock, 

click on the arrow.

Menu lock

Protect settings

with a password

Yes

No

Step 6

To edit the settings or 

remove the menu lock. 

Go into ‘menu lock’, click 

on the ‘no’ icon.

Expert

Date & Time

Service values

Menu lock

Step 5

After the password has 

been set via menu lock. 

All options for settings 

will be removed/locked 

besides these three 

options.

17

IOM 81, Issue 2 - Modulo Thermostat

Menu

Expert

Fan

80.

2

%

19.

1

ºC

Interface Mode

Full menu or hide menu (only 

actual temperature and

humidity)?

Hide

Interface Mode

Full menu or hide menu (only 

actual temperature and

humidity)?

Full

Settings

Functions

Location

Sensor Offset

Display Brightness

Interface Mode

Expert

Select language

Date & Time

Settings

Service values

Menu lock

Factory settings

7.2 Setting Up Interface Lock

Step 5

To deactivate

‘hide mode’, hold the

upper-right corner

of the display for

around 5 seconds.

Step 6

To return to ‘full mode’, 

click on expert mode, go 

back to interface mode 

and select ‘full’ menu.

Step 1

To set up the interface 

lock, go into the expert 

section. Click on ‘settings’.

Step 2

Click on ‘interface mode’.

Step 3

Default setting is on full 

menu. Click on either 

the ‘positive’ or ‘negative’ 

icon to change mode.

Step 4

Once in hide mode.

Click on the arrow to 

activate.

Summary of Contents for Modulo

Page 1: ...Modulo Thermostat Installation and operating instructions Read carefully before installation commissioning and operation...

Page 2: ...ations 5 2 2 Scope of Supply 6 3 Installation 7 3 1 SPC Modulo Installation 7 3 2 Sample Wiring 9 4 Setup 9 4 1 Setup Procedure 9 5 Operation 10 5 1 Overview of Temperatures Humidity 10 5 2 Operating...

Page 3: ...n specialist and by the system user before installation commissioning and operation of the unit This unit is an automatic electronic room thermostat Install the device only in dry rooms and under envi...

Page 4: ...t or the entire system 1 4 Warranty and Liability The Unit has been manufactured and tested with regard to high quality and safety requirements The warranty and liability shall not include however any...

Page 5: ...n SPC Modulo Thermostat 2 1 Speci cations Housing 2 part ABS plastic 75 mm x 95 mm x 30 mm Glass front Display Capacitive touch panel Colour display with 240x320 dots 2 8 inches 7 cm diagonal 1 2 3 Op...

Page 6: ...0 C 60 C no moisture condensation permitted Measuring range Outside the measuring ranges there are larger deviations Internal temperature sensor 0 C 60 C Accuracy 1 C Resolution 0 1 C Internal sensor...

Page 7: ...l conditions Direct sunlight sources of heat and cold e g radiators and windows must be avoided 3 Installation 3 1 SPC Modulo Installation Mount the unit at a suitable location Strip cables by 75 mm m...

Page 8: ...ove the cable cover and connect the electric as described Re t the base and fasten with screw Switch on mains voltage and place SPC Modulo in operation Never remove front cover while Modulo is connect...

Page 9: ...is intended to control This shows the wiring required between the Modulo and the heater Set Functions Assign a switching output to the respective function via the Expert menu in the Settings menu item...

Page 10: ...e settings Back Forward Navigation back to the overview Menu Navigation to the main menu Operating Modes The operating mode shown in colour is currently active and can be changed by selecting a di ere...

Page 11: ...riday or to Monday Sunday Back Next Weekday Sellection of the day of week which is to be set Clock Time table for selecting the time intervals in 30 minute steps Touch individual segments or drag your...

Page 12: ...selected period will be coloured after selecting the colour of the operating mode normal orange Set the times of the other operating modes in the same way Step 3 After completing the setting of the i...

Page 13: ...ation Used to adapt the temperature and humidity of the said local sensor for the selected area Location Set where the device is installed selection of the room icon Display Brightness Adjustment of d...

Page 14: ...tions Overview Operating Mode Main Menu Expert Settings Functions Overview Operating mode Menu Expert Settings Functions Thermostat Thermostat Fan Hysteresis Heating hysteresis of the thermostat funct...

Page 15: ...an be resolved by performing a factory reset Enter expert mode and select Factory Settings as described earlier 6 2 Hard Reset If the thermostat screen is blank and will not illuminate then a hard res...

Page 16: ...P Q R S T U V W X Y Z abc 123 Step 3 Enter password Then click on the arrow Confirm password E A B C D E F G H I J K L M N O P Q R S T U V W X Y Z abc 123 Step 4 Re enter password to con rm Then click...

Page 17: ...ings Service values Menu lock Factory settings 7 2 Setting Up Interface Lock Step 5 To deactivate hide mode hold the upper right corner of the display for around 5 seconds Step 6 To return to full mod...

Page 18: ...ulo Thermostat Final Declaration Although these instruction have been created with the greatest possible care the possibility of incorrect or incomplete information cannot be excluded Subject as a bas...

Reviews: