E L E C T R I C A L   D A T A   F O R   T H E   U S E   O F   L I C E N S E D   E L E C T R I C I A N

WARNING: Shock Hazard! Under No Circumstances Should This Spa Be Installed By Anyone Other 

Than A Certified Licensed Electrician!

W A R N I N G !   U S E   C O P P E R   C O N D U C T O R S

All wiring 

MUST

be in accordance with the National Electrical Code and All Local Codes.

S-2 Series Convertible 

Equipment Package

A GFCI Must Be A Integral
Part Of The Connection

Safety Factors In
Placement of the 20 Amp
Receptacle

Wire Sizing Must Meet
Electrical Codes

A NEMA 5-20R 20 Amp
Receptacle is Required

WARNING: 

This GFCI Plug provides
ground fault protection for
the spa and should never
be removed, altered or dis-
abled for any reason!

Isolated, Dedicated 120
Volt, 20 Amp Circuit Is
Required

The National Electrical Code
requires that both 120 and 240
volt circuits be protected by a
Ground Fault Circuit Interrupter
(GFCI) and a Disconnect Switch.
See NEC Article 680-42 & 680-12

Your spa has a factory installed 120 volt power cord with a GFCI 20 amp
configured plug connector designed for use with a Nema 5-20R recepta-
cle. See below for further details. Conversion of the S-2 from the standard
120 volt cord connection to a 240 volt hard wire connection must be
completed by a Licensed Electrician in accordance with all codes.

Special consideration should be
given to safety when selecting a
location for the 20 Amp recepta-
cle.The receptacle should be
placed no closer than six (6’) feet
(180cm) from the spa and in such
a manner as to be out of the way
of traffic to and from the spa and
normal foot traffic.The power
cord should be situated so it will
not cause any other type of haz-
ard.

This GFCI Plug has one vertical
and one horizontal blade in addi-
tion to a grounding prong.This
plug configuration is to be
plugged into a like receptacle.
Under no circumstance should
this configuration be modified.

A NEMA 5-20 Amp Receptacle is
required for a Power Cord instal-
lation.This receptacle must be
installed in accordance with the
National Electrical Code and All
Local Codes.

All installations are different.Wire
sizing must meet the National
Electrical Code and all Local
Code Specifications.

The S-2 is a convertible equipment pack designed to

except either 120 or 240 volt power input.

All 120 volt installations require a
isolated, dedicated 120 volt circuit
to provide the power necessary
for the proper operation of the
electrical equipment.

Ground fault interrupter plug & power cord

fished through arched corner of the spa.

NEMA 5-20 20 Amp Receptacle

GFCI Equipped Plug

Load Center

Summary of Contents for Genius G-1.5

Page 1: ...This Manual Contains IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Trend Setting Innovations Since 1973 Spa Owner s Manual Smart S 2 Genius G 1 5 G 2 Series...

Page 2: ...ical Wiring Must be Installed By A Licensed Electrician 120Volt Installation 5 NEMA 5 20Amp Receptacle 5 Isolated Dedicated 120Volt 20Amp Circuit 5 Ground Fault Circuit Interrupter Plug 5 6 Cabinet Pa...

Page 3: ...tory system problems or diabetes should consult a physician before using a spa F Persons using medication should consult a physician before using a spa since some medication may induce drowsiness whil...

Page 4: ...disease circulatory problems diabetes or high blood pressure should check with their physician before using spas Additionally people taking medications causing drowsiness such as tran quilizers narcot...

Page 5: ...owing suggestions and recommendations will help you select a safe and compatible site for your spa maximizing your enjoyment The site must provide a solid foundation with a minimum load bear ing capac...

Page 6: ...tects your spa equipment from the effects of residual calcium hardness and total alkalinity problems Turn power off at the spa consoles and deactivate discon nect switches at the GFCI plug or load cen...

Page 7: ...cord connection to a 240 volt hard wire connection must be completed by a Licensed Electrician in accordance with all codes Special consideration should be given to safety when selecting a location fo...

Page 8: ...ing the Reset button returns power to the spa equipment This same button is used to Reset the GFCI during a test cycle See page 1 number 4A WARNING Shock Hazard No User Serviceable Parts Spa Cabinet p...

Page 9: ...y installed 120 Volt system to a hardwired 240 volt system must be completed by a Certified Licensed Electrician All 240 Volt operations wiring must be permanently hard wired and installed in grounded...

Page 10: ...onduit and installed in compli ance with the National Electrical Code and all Local Codes All installations are different Wire sizing must meet the National Electrical Code and all Local Code Specific...

Page 11: ...Than A Certified Licensed Electrician A grounding lug has been provided on the exterior of the pack chassis to allow connection of a ground wire to a local grounding point to be estab lished in compli...

Page 12: ...10...

Page 13: ...11...

Page 14: ...12...

Page 15: ...13...

Page 16: ...14...

Page 17: ...15...

Page 18: ...spa filter cartridge pleats which may not be thoroughly removed by the garden hose To remove such substances soak the filter in a solution of filter cleaner Various brands of such cleaners are readily...

Page 19: ...hrice Monthly TwiceWeekly Twice Monthly TwiceWeekly Weekly Weekly Twice Monthly HeavyUsage Daily Daily Weekly Daily Weekly TwiceWeekly As Required Weekly As Required IMPROPER WATER BALANCE WILL DAMAGE...

Page 20: ...a soft rag or paper towel and wiping the surface in a circular motion Removing Tub Ring Tub ring is best removed with a specialized commercially available cleaner such as Sun Surface Cleaner Ask your...

Reviews: