E L E C T R I C A L D A T A F O R T H E U S E O F L I C E N S E D E L E C T R I C I A N
WARNING: Shock Hazard! Under No Circumstances Should This Spa Be Installed By Anyone Other
Than A Certified Licensed Electrician!
W A R N I N G ! U S E C O P P E R C O N D U C T O R S
All wiring
MUST
be in accordance with the National Electrical Code and All Local Codes.
S-2 Series Convertible
Equipment Package
A GFCI Must Be A Integral
Part Of The Connection
Safety Factors In
Placement of the 20 Amp
Receptacle
Wire Sizing Must Meet
Electrical Codes
A NEMA 5-20R 20 Amp
Receptacle is Required
WARNING:
This GFCI Plug provides
ground fault protection for
the spa and should never
be removed, altered or dis-
abled for any reason!
Isolated, Dedicated 120
Volt, 20 Amp Circuit Is
Required
The National Electrical Code
requires that both 120 and 240
volt circuits be protected by a
Ground Fault Circuit Interrupter
(GFCI) and a Disconnect Switch.
See NEC Article 680-42 & 680-12
Your spa has a factory installed 120 volt power cord with a GFCI 20 amp
configured plug connector designed for use with a Nema 5-20R recepta-
cle. See below for further details. Conversion of the S-2 from the standard
120 volt cord connection to a 240 volt hard wire connection must be
completed by a Licensed Electrician in accordance with all codes.
Special consideration should be
given to safety when selecting a
location for the 20 Amp recepta-
cle.The receptacle should be
placed no closer than six (6’) feet
(180cm) from the spa and in such
a manner as to be out of the way
of traffic to and from the spa and
normal foot traffic.The power
cord should be situated so it will
not cause any other type of haz-
ard.
This GFCI Plug has one vertical
and one horizontal blade in addi-
tion to a grounding prong.This
plug configuration is to be
plugged into a like receptacle.
Under no circumstance should
this configuration be modified.
A NEMA 5-20 Amp Receptacle is
required for a Power Cord instal-
lation.This receptacle must be
installed in accordance with the
National Electrical Code and All
Local Codes.
All installations are different.Wire
sizing must meet the National
Electrical Code and all Local
Code Specifications.
The S-2 is a convertible equipment pack designed to
except either 120 or 240 volt power input.
All 120 volt installations require a
isolated, dedicated 120 volt circuit
to provide the power necessary
for the proper operation of the
electrical equipment.
Ground fault interrupter plug & power cord
fished through arched corner of the spa.
NEMA 5-20 20 Amp Receptacle
GFCI Equipped Plug
Load Center