4.1.2  Menu structure and submenus 

The unit has 3 main submenus that are controlling EDID, System settings and device settings. You may 

reach them using the RIGHT arrow button. Use UP and DOWN button to cycle through the settings.  
Use the right button to initiate the blinking cursor, then use UP and DOWN button to change the setting.  

4.1.3  DEVICE GROUP 

LED Brightness

 

0-10 

LCD Backlight

 

0-10 

LCD Contrast

 

0-10 

Int. IR Remote

  

on/off 

Deactivates/Activates the front IR receiver  

Int. IR Indication

  on/off 

If active POWER LED will blink while receiveing IR commands 

  

4.1.4  SYSTEM GROUP

 

Sys Temperature

   

Display will show internal temperature in degrees centigrade 

Reset to Default

   

go to 4.3 

Remote Control 

 

The MATRIX-X1616 has 3 options for remote control 

 

 

R  

= RS-232 

 

 

E  

= Ethernet using GUI 

 

 

T  

= Telnet (RS-232 commands via Ethernet) 

You can see the current remote setting in the upper right corner of the main display that can be reached 

using the LEFT button ! 

  

 

   

 

4.1.5  EDID MANAG. GROUP 

The most powerful tool of our MATRIX-X1616 is the EDID management and our unique SingleEDID 
technology. Opposite to extenders that should be EDID transparent and forward the display EDID to the 

source a matrix requires the exact opposite. Since a matrix can have a variety of different displays 
connected to the outputs and it is most likely that one input is connected to all available outputs there is no 

choice but controlling the EDID for the sources. We have several options how to control the EDID. 
They are explained in the following paragraphs.  
Once you have reached the EDID MANAG. GROUP following settings are available: 

EDID Control 

Common/Individual 

 

This setting determins if EDID information is programmed for each input individually 

 

(Individual)

 or all inputs have the same EDID programming 

(Common). 

Typically 

 

you would work in the COMMON setting (Default) and after selecting or programming 

 

the SingleEDID the unit would copy the setting to all other inputs.  Individual EDID 

 

programming could be necessary if you have special requirements or work in a 

 

multiroom setup.  

Input Select 

If you have chosen INDIVIDUAL EDID programming you can now select the Input 

 

you want to change. After having selected the input you can choose between the 

 

following EDID options. 

Do not forget to STORE !!!

 

EDID Mode

 

Learned /SingleEDID/Default EDID/3D 8CH Audio/3D 2CH Audio

 

 

use right arrow button to change, up/down button to cycle through the options 

DEFAULT

 

EDID Information is (1280x720p/60Hz), this is an EDID that is compatible with most 

 

displays on the market 

 

3D All Audio

 

Both of these contain a 3D EDID as required by BluRay Players to activate the 3D  

3D 2CH Audio

  output. One is set for 2 CH PCM audio the other for 8 Channel PCM.  

 

 

Summary of Contents for MATRIX-X1616

Page 1: ...www spatz tech de Manual MATRIX X1616 09 2012 2012 SPATZ Technical changes reserved...

Page 2: ...is entirely made in Germany by german companies and I am sure you have noticed this while unpacking Here what we found is special up to 16 DVI HDMI 1 3 inputs up to 16 DVI HDMI 1 3 outputs 32 physica...

Page 3: ...ible with the unit the ability to learn EDID makes the matrix future proof with upcoming 3D formats Each input card offers 2 inputs and 2 monitor outputs that may be used for local monitoring or expan...

Page 4: ...a blinking cursor indicating the you can now change the setting using UP or DOWN button If you want to permanently store your setting do not forget to press the STORE button You may leave the submenu...

Page 5: ...ty of different displays connected to the outputs and it is most likely that one input is connected to all available outputs there is no choice but controlling the EDID for the sources We have several...

Page 6: ...g you have no Audio EDID any longer So if you have no audio on your HDMI signal then most likely you are in DVI mode Pls change back to HDMI Video Resolution go to 4 1 6 COLOR SPACE go to 4 1 7 Audio...

Page 7: ...FL FR 02 DolbyDigital AC 3 5 1 48kHz 640kbps max speaker FL FR LFE FC RL RR 03 MPEG 1 2 0 48kHz 192kbps max speaker FL FR 04 MP3 2 0 48kHz 192kbps max speaker FL FR 05 MPEG 2 multichannel 5 1 48kHz 52...

Page 8: ...Windows versions You will also find a configuration file for Hyperterminal that automatically sets the communication parameters The settings are COM1 57600 8N1 A standard RS 232 cable is all you need...

Page 9: ...ypically can reach 15m 50ft without any equalizing if you are using our cable and the HDMIMAX at the end of the cable 70m 230ft are possible at 1080p The Dual Cat5 outputs can drive 40 50m 165ft of so...

Page 10: ...6 RET Preset O RET Nb 1 16 RET Output Select I RET Nb 1 16 RET Input per output HPB RET Nb 1 16 RET Hotplug Break example Switching output 2 to input 4 O CR 2 CR IN CR 4 CR 7 2 Using the graphical use...

Reviews: