After the dropbox passes through the Skamotec enclosure,
slide the steel closure plate up against the Skamotec and
attach the dropbox to the steel closure plate using rivets.
Ensure that the instructions supplied with the drop box are
followed.
To protect the drop box against undesired ingress of debris or
rodents/birds ensure that the supplied grilles are fitted as
shown in the following image:
A 25MM CLEARANCE TO COMBUSTIBLES MUST BE
MAINTAINED FOR ALL FLUE COMPONENTS.
ENSURE THAT ANY CHIMNEY CHASE OR DEAD AIR
SPACE ADJACENT TO THE FLUE LINERS IS
ADEQUATELY VENTILATED BY PROVISION OF
DEDICATED VENT(S) TO THE BUILDING EXTERIOR OR
VENTILATION THROUGH A DEDICATED CHIMNEY LINER
VENT.