Spartherm Mellino Installation And Service Instructions Manual Download Page 24

GB

 24

Parameter 53 allows the adjustment of the operating mode Modula-
tion or StandBy, see also chapter 10.3.

8.8 ROOM TEMPERATURE SENSOR

The room temperature sensor is secured underneath the cover plate of the 
controller electronics. Where required, the sensor can be extended to 10 
metres with a 2-wire copper line (line cross.section min. 0.5 sqmm).

9. WARRANTY

Details on the warranty services, exemption of warranty as well as liability 
conditions can be obtained in the „Operating instructions Mellino“.

10. APPENDIX

10.1 PARAMETER LIST 

Here is a list of all available parameters (see also chapter 6, level 8). The 
parameters can only be adjusted within the specified limits. An adjustment 
of the limits is only possible in the factory (not on the stove) and is also not 
necessary. The values below ar eonly examples!

Parameters crossed out are not relevant for the current constellation of the 
Mellino pellet stove. 

Para-

meter Bezeichnung des Parameters Einheit min max Wert Beschreibung

0

Fuel ignition timeout

min

1 100

30

Innerhalb der Zeit muss T abgas > para 54 sein

1

Ignition test timeout

min

1 100

3

Wartezeit für Zündungsüberprüfung

2

fuel type

-

1

3

2

Auf 2 belassen sonst gilt para 92 nicht

3

Heat Up Feeder OFF time

0,1sec 1 255

1

Pelletmotor AUS in Heat Up Phase

4

Heat Up Feeder ON time

0,1sec 1 255

254

Pelletmotor EIN in Heat Up Phase

5

Fuel ignition Feeder 1 OFF time

0,1sec 1 255

1

Pelletmotor AUS in Fuel ignition Phase

6

Fuel ignition Feeder 1 ON time

0,1sec 1 255

39

Pelletmotor EIN in Fuel ignition Phase

7

Ignition test Feeder 1 OFF time

0,1sec 1 255

1

Pelletmotor AUS in Ignition test Phase

8

Ignition test Feeder 1 ON time

0,1sec 1 255

39

Pelletmotor EIN in Ignition test Phase

9

Pow er 1 Feeder OFF time

0,1sec 0

0

0

Wird selbsttätig errechnet

10

Pow er 1 Feeder ON time

0,1sec 1

30

15

Pelletmotor EIN in Burning Phase, Pow er 1

11

Pow er 2 Feeder OFF time

0,1sec 0

0

0

Wird selbsttätig errechnet

12

Pow er 2 Feeder ON time

0,1sec 0

0

0

Wird selbsttätig errechnet

13

Pow er 3 Feeder OFF time

0,1sec 0

0

0

Wird selbsttätig errechnet

14

Pow er 3 Feeder ON time

0,1sec 0

0

0

Wird selbsttätig errechnet

15

Pow er 4 Feeder OFF time

0,1sec 0

0

0

Wird selbsttätig errechnet

16

Pow er 4 Feeder ON time

0,1sec 0

0

0

Wird selbsttätig errechnet

17

Pow er 5 Feeder OFF time

0,1sec 0

0

0

Wird selbsttätig errechnet

18

Pow er 5 Feeder ON time

0,1sec 1

39

34

Pelletmotor EIN in Burning Phase, Pow er 5

Limits

Para-

meter Bezeichnung des Parameters Einheit min max Wert Beschreibung

19

Stop Fire Fan 1 speed

-

0 255

255

Abgasventilatordrehzahl beim Auslöschen

20

Test fire Fan 1 speed

-

0 255

18

Druckdifferenz Abgasgebläse bei test fire

21

Heat Up Fan 1 speed

-

0 255

14

Druckdifferenz Abgasgebläse bei  Heat Up

22

Fuel ignition Fan 1 speed

-

0 255

26

Druckdifferenz Abgasgebläse bei  fuel ignition

23

Ignition test Fan 1 speed

-

0 255

28

Druckdifferenz Abgasgebläse bei ignition test

24

Pow er 1 Fan 1 speed

-

0 255

14

Druckdifferenz Abgasgebläse in Pow er 1

25

Pow er 2 Fan 1 speed

-

0

0

0

Wird selbsttätig errechnet

26

Pow er 3 Fan 1 speed

-

0

0

0

Wird selbsttätig errechnet

27

Pow er 4 Fan 1 speed

-

0

0

0

Wird selbsttätig errechnet

28

Pow er 5 Fan 1 speed

-

0 255

21

Druckdifferenz Abgasgebläse in Pow er 5

29

Test Fire Fan 2 speed

-

0 255

30

Drehzahl Konv.lüfter bei Test fire Phase

30

Stop Fire Fan 1 speed

-

0 255

170

Drehzahl Konv.lüfter bei Stop fire Phase

31

Heat up Fan 2 speed

-

0 255

30

Drehzahl Konv.lüfter bei Heat Up Phase

32

Fuel ignition Fan 2 speed

-

0 255

30

Drehzahl Konv.lüfter bei Fuel ignition Phase

33

Ignition test Fan 2 speed

-

0 255

30

Drehzahl Konv.lüfter bei Ignition test Phase

34

Pow er 1 Fan 2 speed

-

0 255

128

Drehzahl Konv.lüfter auf Stellung 1

35

Pow er 2 Fan 2 speed

-

0 255

145

Drehzahl Konv.lüfter auf Stellung 2

36

Pow er 3 Fan 2 speed

-

0 255

162

Drehzahl Konv.lüfter auf Stellung 3

37

Pow er 4 Fan 2 speed

-

0 255

179

Drehzahl Konv.lüfter auf Stellung 4

38

Pow er 5 Fan 2 speed

-

0 255

196

Drehzahl Konv.lüfter auf Stellung 5 (Auto)

39

Quickheat Fan 2 speed

-

0 255

205

Drehzahl Konv.lüfter auf Stellung Hi

40

Stop Fire Fan 3 speed

-

0 255

0

Drehzahl Lüfter 3 w ährend Stop fire Phase

41

Test fire Fan 3 speed

-

0 255

0

Drehzahl Lüfter 3 w ährend Test fire Phase

42

Heat Up Fan 3 speed

-

0 255

0

Drehzahl Lüfter 3 w ährend Heat Up Phase

43

Fuel ignition Fan 3 speed

-

0 255

0

Drehzahl Lüfter 3 w ährend Fuel ignition Phase

44

Ignition test Fan 3 speed

-

0 255

0

Drehzahl Lüfter 3 w ährend Ignition test Phase

45

Pow er 1 Fan 3 speed

-

0 255

0

Drehzahl Lüfter 3 in Burning phase, Pow er 1

46

Pow er 2 Fan 3 speed

-

0 255

0

Drehzahl Lüfter 3 in Burning phase, Pow er 2

47

Pow er 3 Fan 3 speed

-

0 255

0

Drehzahl Lüfter 3 in Burning phase, Pow er 3

48

Pow er 4 Fan 3 speed

-

0 255

0

Drehzahl Lüfter 3 in Burning phase, Pow er 4

49

Pow er 5 Fan 3 speed

-

0 255

0

Drehzahl Lüfter 3 in Burning phase, Pow er 5

50

Cool fluid exit temp. Difference

0,1°C

0

80

20

Hysterese für Heizleistung (20 = 2 °C)

51

Water / air temperature

1/5 °C 15 40

120

Soll- Raumtemperatur (120 = 24,0°C)

52

Water temp. In stove mode

°C

0

0

0

nur bei Wassergeräten

53

Cool fluid entry temp. Difference

0,1°C

0

80

0

0 für Betriebsart Modulation, 20 für Standby

54

Ignition test (flue) gas temperature

°C

0 255

127

Schw elle für Ende Zündphase

55

Modulation start (at flue) gas temp.

°C

0 128

250

Schw elle für Leistungsbegrenzung

56

Heating device OFF (at flue)  temp.

°C

0 255

102

Abschaltschw elle Zündelement

57

Max. error (flue) gas temperature

°C

0 144

280

Abschaltschw elle Überhitzung

58

Fan 2 as ambient min. (flue) temp.

°C

0 255

120

Konvektionslüfter erst ab dieser Temp aktiv

59

No fuel (error) (at flue) gas temp.

°C

0 255

105

Ausschaltschw elle für Untertemperatur

60

Fan 1 blow  cleaning period

min

0 255

60

Zeitabstand zw ischen 2 Reinigungsvorgängen

61

Fan 1 blow  cleaning duration

sec

0 255

65

Dauer eines Reinigungsvorgangs

62

Fan 1 blow  cleaning speed

-

0 255

255

Abgasventilatordrehzahl beim Reinigen

Limits

Summary of Contents for Mellino

Page 1: ...Installation and service instructions Pellet Stove Mellino...

Page 2: ...ional level creating feelings of security and comfort To ensure this is achieved we recommend that you carefully read these operating instructions so that you can become quickly and comprehen sively a...

Page 3: ...5 1 Das Display 10 5 2 The remote control 11 6 Service menu 11 7 Mechanical components 16 7 1 Rear wall 16 7 2 Removing the combustion chamber door 17 7 3 Combustion chamber lining 17 7 4 Screw feeder...

Page 4: ...of the respective firing installation direc tive of the federal state and the fire protection guidelines of the VFK The assembly and service instruction must be stored in a safe place and when request...

Page 5: ...handle and the cold hand The glove is not fire proof 1 4 ACCESSORIES The following accessories are optionally available for the Mellino Hot air or convection air blower Part no 1015055 100 mm Flue pip...

Page 6: ...at of the combustion cham ber door the non combustible layering must be installed at least 500 mm to the front and at least 300 mm on each side 2 2 SAFETY DISTANCES A minimum distance of 150 mm must b...

Page 7: ...d with a wall distance of 100 mm see 2 2 Safety distances The hole for the wall lining on the chimney must be located 192 mm above the flooring A fine adjustment can be carried out using the height ad...

Page 8: ...ime in the same room or linked space with a pellet stove is forbidden due to smoke or flue gas escaping despite the combustion chamber room being closed a Via an external combustion air connection If...

Page 9: ...ntrol system in the Mellino is characterised by several special features 4 1 DIFFERENTIAL PRESSURE CONTROL The differential pressure control serves to provide constant conditions for combustion and to...

Page 10: ...tove An infrared remote control is also available for the most important functions 5 1 THE DISPLAY The first 3 symbols at top left are warnings Adjacent to these 3 symbols is the receiver for the remo...

Page 11: ...t 6 SERVICE MENU The service menu is sub divided into 13 levels The level is displayed as a value in square brackets e g 5 Levels 1 to 6 are freely accessible level 7 contains a password request for a...

Page 12: ...ey at the top left 2 times to return to the main menu Level 3 Display representation when idling Depending on the setting the display shows different information approx 2 minutes after pressing the ke...

Page 13: ...after 30 seconds for safety reasons and Enter has to be pressed again An audible signal sounds when cancelling You have to keep pressing Enter until the first pellets fall into the burner pot Then you...

Page 14: ...d as follows for viewing the status Go to level 9 in the service menu using the setting keys d i n appears Press Enter i 01 appears That is the digital input 01 Use the menu keys to go to the desired...

Page 15: ...ese components are still functional Level 12 Service counter Once the service menu has been activated see level 7 in level 12 you can query different counters for different events The allocation is as...

Page 16: ...Press the ESC key at the top left 3 times to return to the home position A table with the error codes can be found at the end of the service instructions 7 MECHANICAL COMPONENTS The pellet stove Mell...

Page 17: ...e Pull the door slightly to the front and when lowering pull out of the top guide The assembly is carried out in the reverse order 7 3 COMBUSTION CHAMBER LINING The firebox lining comprises Vermiculit...

Page 18: ...and pull out of the guide to the front If necessary remove the connecting line from the operating panel The assembly is carried out in the reverse order 7 4 SCREW FEEDER Removing the gear motor see 8...

Page 19: ...GB 19 GB Pic 2 Pic 3 Pic 4 Pic 5...

Page 20: ...led down Take care that the pellet supply tank is close so that no tools can fall into it 8 1 MAINS FUSE The Mellino is safeguarded using a mains fuse F1 T2A 10 3 x 38 mm A replacement fuse is also in...

Page 21: ...ert the replacement Attention if the fuse has tripped find out the reason for the fuse tripping and eliminate this before replacing the fuse 8 3 SCREW FEEDER DRIVE The screw feeder is driven via a gea...

Page 22: ...cleaning the spiral housing This procedure makes the correct positioning of the motor in the spiral housing easier when assembling Attention do not bend the fins of the flue gas fan when cleaning Thi...

Page 23: ...fan using a squeeze type threaded joint Remove the power plug from the socket Remove the back wall Undo the squeeze type threaded joint and pull out the sensor If this should block unscrew the flue g...

Page 24: ...peed 0 255 28 Druckdifferenz Abgasgebl se bei ignition test 24 Pow er 1 Fan 1 speed 0 255 14 Druckdifferenz Abgasgebl se in Pow er 1 25 Pow er 2 Fan 1 speed 0 0 0 Wird selbstt tig errechnet 26 Pow er...

Page 25: ...FF level 0 255 0 nur bei Flammensensor 0 no fire 255 full fire 80 Flame OFF detection delay sec 0 255 0 nur bei Flammensensor 81 Underpressure setpoint 0 255 0 nur in Verbindung mit einemRauchsauger 8...

Page 26: ...error is reported determine and eliminate the cause The errors can be reset by pressing the On Off key The stove can only be restarted after that If the error cannot be reset contact customer service...

Page 27: ...em connection of convection fan 7 PE body 8 PE to control system 9 Power cable with a plug 10 PE geared motor 10 5 CIRCUIT DIAGRAM TERMINAL STRIP X2 CONTROLLER 1 NTC room temperature sensor 2 Flue gas...

Page 28: ...merk van wereldformaat voor uw woonkamer wiatowa marka do Pa stwa salonu 1 D Ihr Fachh ndler UK Your specialist dealer F Votre revendeur sp cialis IT Il vostro rivenditore specializzato E Sus comerci...

Reviews: