c. Low voltage recovery to set switching voltage 
6.    Right arrow shows low voltage switch to mains status. 
7.    Left arrow shows the low pressure is restored to the inverter state 
8. LCD turns red when no function control display, fixed display after power on. 

9.

  The battery icon is low voltage status. 

 

10.

  Case  buttons are:  Add  button, Function  button, 

Minus button. 
a. The

 add button

 is only valid in setting voltage (0.1V per trigger). 

b. The 

minus button 

is only valid in setting voltage (0.1V per trigger). 

c.  The 

function  button

  has  3 kinds of independent display interface types:  BAT-V 

LV-SW,  HV-SW.  Pressing the button will cycle types.  Default interface is BAT-V. 
Without trigger signal in 10 seconds, it will restore to BAT-V interface. 
d.  When function setting display BAT-V interface, LCD digital displays actual 
tracking battery voltage. 
e. When function setting display LV-SW interface, LCD digital displays low-voltage 
cut-off  voltage (default value). You can  press  the  add/minus  buttons  to modify the 
default value. Press and hold the function button for 3 seconds to save the value. Then 
the interface will restore to BAT-V interface. 
f. When function setting display HV-SW interface, LCD digital displays low-voltage 
recovery voltage (default value). You can  press the add/minus buttons to modify the 
default value. Press and hold the function button for 3 seconds to save the value. Then 
the interface will restore to BAT-V interface. 
g. LCD backlight. Without a pressed button within 60 seconds, the interface will go 
dark. 

 
V. Installation: 

 
1.

 

The installation should only be carried out by persons having relevant professional 

skills. If there is any doubt, always contact an authorized expert. 
2.

 

Before installation, ensure that the inverter output as well as AC mains supply are 

voltage free and equipped with a safety lock system to prevent unintentional start of 
the power transfer controller. 
3. The cross sections of the used cables must be selected and secured in compliance 
within applicable law.   
4. Ensure that the connection cables are connected properly and have good contact, as 
loose contacts may cause smoldering fire.   
5. Use the supplied cage clamps to connect the protective earth conductor on the 
inverter.   
6. If the inverter has no earth connection, the negative battery terminal must be 
connected to the earth. 

Summary of Contents for SP-TS4500PLUS

Page 1: ...oy for children 3 Check the power transfer controller and connection cables before starting operation If you detect any damages e g transport damages on the power transfer controller do not start operation Damaged connection cables must be replaced immediately 4 The power transfer controller may only be operated in a dry environment to avoid getting humid or wet otherwise there is a risk of life t...

Page 2: ...ing the switching voltage function 2 BAT V interface normal displaying battery voltage 3 HV SW interface setting the recovery voltage 4 12V 24V 48V interface displaying after the system identification 5 LCD digital a Battery voltage b Low voltage setting switching voltage ...

Page 3: ...ds to save the value Then the interface will restore to BAT V interface f When function setting display HV SW interface LCD digital displays low voltage recovery voltage default value You can press the add minus buttons to modify the default value Press and hold the function button for 3 seconds to save the value Then the interface will restore to BAT V interface g LCD backlight Without a pressed ...

Page 4: ...controller for three phase current 9 After ensuring all the steps above connect the controller separately with public power inverter load and battery 10 Turn on the switch after all the cables are well connected Attention 1 The dual power transfer controller is simply a switch between off grid power system and public power it can t replace the charge controller in the off grid system Connection Ty...

Page 5: ...tching voltage and the switching action is LCD The right arrow blinks the LCD Left arrow turns off and the battery icon blinks b When it is detected that the battery voltage recovers to 25V for 2 seconds system default value is 25V it is the low voltage recovery voltage and the switching action is LCD The right arrow turns off the LCD Left arrow blinks and the battery icon stops blink 48V System 1...

Page 6: ...ecovery Default 13 5V 27V 54V Application Off grid Solar or Wind System Product Size 7 4 X 6 7 X 2 8 Weight VIII Environmental Protection Notes At the end of its useful life this product must not be disposed of together with normal household waste but has to be dropped off at a collection center for the recycling of electrical and devices The materials of this product are recyclable With recycling...

Page 7: ...the following conditions we need to charge even if it is in the guarantee period User did not operate according to the user s manual Use the product under conditions which is beyond using standard and technical requirements Repaired by yourself or reformed by yourself Used during inappropriate environmental condition which can cause breakdown and aging of the product Improper carrying or storage F...

Reviews: