Thermal protector

All compressors are fitted with a thermal protector. This automatically deactivates the motor in the

event of overloading or overheating to protect the unit against damage.

If overheating or overloading causes the thermal protector to switch off the compressor, proceed as 

follows:

1. Turn the on/off switch to 0 ("OFF") and allow the unit to cool for approx. 30 minu-

tes.

2. The unit can be switched on again after approx. 30 minutes.

Deactivating the compressor

The unit should be deactivated if the compressor is not used for a longer period of time.

Warning:

The unit should be deactivated if it appears not to be operating (i.e. the motor is not

running). This is the case if the motor has built up the required maximum pressure

and the automatic shut-off switch has been triggered. The motor is in standby mode

and activates immediately again if the pressure drops below a particular value.

Turn the on/off switch to the 0 position ("OFF") to deactivate the unit. 

Maintenance work

The following maintenance work should be realised at the recommended intervals to increase the ser-

vice life of your compressor.  

Monthly

Carry out visual inspection

Carry out a visual inspection of the unit once a month. Ensure in particular that no connections or

screws have loosened and examine the general condition of pressure hoses.

Draining condensate water from the tank

Note:

Condensate emerging from the unit should be removed with a suitable medium (e.g.

a cloth).

Drain condensate water from the tank daily after use by releasing the drain valve. The tank should be

under pressure during this procedure.

Open the drain valve once for this purpose. Please be sure to close the drain valve once all conden-

sate water has been sufficiently drained.

Summary of Contents for AC-500

Page 1: ...Bedienungsanweisung 2 9 Operating Instructions 9 16 Gebruiksanwijzing 17 24 Bruksanwisning 24 31 Sparmax AC 500 ...

Page 2: ...äßige Erdung nicht vorhanden sein übernimmt der Hersteller für eventuelle Schäden bzw Unfälle keine Haftung Der Kompressor ist für die auf dem Typenschild entsprechende Betriebsspannung ausgelegt und darf ausschließlich an einer ordnungsgemäß installierten und abgesicherten Steckdose betrieben werden Die Spannung muss der auf dem Etikett der technischen Daten angegebenen Spannung entsprechen Die S...

Page 3: ...e zum Betrieb von handelsüblichen Airbrush Apparaten konstruiert Beachten Sie auch folgendes Zur bestimmungsgemäßen Verwendung gehört auch die ordnungsgemäße Entsorgung verwendeter Betriebsmittel Jeder anderweitige Gebrauch als der in dieser Bedienungsanweisung beschriebenen gilt als nicht bestimmungsgemäß Konsequenzen hieraus trägt allein der Betreiber Es ist nicht zulässig den Kompressor konstru...

Page 4: ...delsüblichen Qualität oder Eignung für einen bestimmten Zweck haben über die hier angegebe ne Gewährleistungszeit hinaus Gültigkeit Vor der Erstinbetriebnahme Gerät auspacken Bitte stellen Sie nach dem Auspacken sofort sicher dass der Kompressor keine Transportschäden auf weist Andernfalls unterlassen Sie bitte die Verwendung des Gerätes und wenden Sie sich an Ihren Händler Stellen Sie sicher dass...

Page 5: ...f und stoppt automatisch wenn sein Höchstdruck erreicht ist Wird dem Kompressor Luft entnommen und unterschreitet der Luftdruck im Kompressor 40 PSI 2 8 bar läuft der Kompressor an bis er wieder seinen Höchstdruck erreicht hat Arbeitsdruck einstellen Der gewünschte Arbeitsdruck kann am Druckregler mit gedrücktem Hebel an dem Airbrushgerät ein gestellt werden Die Anzeige des Arbeitsdrucks erfolgt a...

Page 6: ...er Motor maximalen Druck auf gebaut und die Automatik geschaltet hat Der Motor befindet sich in einem Stand by Modus und springt sofort wieder an wenn der Druck unter einen bestimmten Wert fällt Um den Kompressor auszuschalten schalten Sie den Ein Aus Schalter in Stellung 0 Aus Sichtkontrollen durchführen Führen Sie einmal nach Gebrauch eine Sichtkontrolle des Kompressors durch Achten Sie dabei be...

Page 7: ...er dem Wasserabscheider mit dem Finger nach oben bis alles Wasser entwichen ist Wenn Sie den Ablass Hebel wieder loslassen schließt er automatisch Der Tank muss dabei unter Druck stehen Technische Daten Nachfolgend erhalten Sie eine Tabelle mit den Leistungswerten des Kompressors AC 500 Modell Spannung Leistung Luft Auto stop Tank Laut Gewicht leistung inhalt stärke netto Volt Hz Watt LPM bar PSI ...

Page 8: ...uf Wasserabscheider offen Wasserabscheider schließen Nicht genutzer Luftauslass Schließen des Luftauslasses offen mittels Abdeckkappe Defekter Luftschlauch oder Alle Schläuche und Verbindungen defekte Verbindung auf Dichtheit prüfen Kompressor schaltet nicht ein Druckschalter defekt Druckschalter durch eine Fach wenn Druck unter Minimum werkstatt auswechseln lassen steht bzw schaltet bei max Druck...

Page 9: ...er Plug 15 Kompressor Compressor 16 Sicherheitsbügel Protective frame 17 Ein Ausschalter On off switch 18 Schlauch Straight air hose 19 Druckeinstellschraube Pressure regulator 20 Einlass Inlet 21 Filtergehäuse Filter cover 22 Ablassventil Drain valve 23 Fächerscheibe Fan 24 Filter Element Filter element 25 Filterhalter Support 26 Filter Kappe Filter cap 27 Ablassventil Drain valve 28 Filtergehäus...

Page 10: ... liability for any subsequent damage injury or accidents occurring in the absence of correct earthing The unit is designed for standard voltage see technical data label and should only be connected to a correctly installed and earthed electrical socket Voltage should correspond to the voltage specified on the technical data label The socket to which the unit is connected should be easily accessibl...

Page 11: ... commercially available airbrush devices Please also heed the following Correct use also includes the realisation of maintenance work described in this operating manual and correct disposal of operational media utilised Any use other than that described in this operating manual is regarded as incorrect The operator is solely responsible for the consequences of such incorrect use Design and constru...

Page 12: ...o commercial quality or suitability for a particular purpose has validity beyond the warranty period stipulated Prior to initial commissioning Unpacking the unit Check the unit for any transportation damage after unpacking the compressor Or else do not use the compressor Check the voltage on the technical data label Note It is sensible to retain packaging materials for future use should you wish t...

Page 13: ...matically deacti vates the motor after it has build up the maximum pressure required The motor is automatically reactivated when the pressure reaches 40psi 2 8 bar in the event of air being removed from the pressure tank Setting the working pressure The desired working pressure can be set using the pressure regulator with the airbrush trigger depres sed The working pressure is indicated on a press...

Page 14: ...off switch has been triggered The motor is in standby mode and activates immediately again if the pressure drops below a particular value Turn the on off switch to the 0 position OFF to deactivate the unit Maintenance work The following maintenance work should be realised at the recommended intervals to increase the ser vice life of your compressor Monthly Carry out visual inspection Carry out a v...

Page 15: ...ressed until the water has drained out After the water has been drai ned release the knob The knob will close automatically when the tank is under pressure The tank should be under pressure during this procedure Technical data The following is a table of performance values of individual compressor types Model Voltage Power Airflow Auto stop Tank Noise Weight frequency capacity level net Volt Hz Wa...

Page 16: ...build up bottom of the tank adequate pressure Moisture trap not closed Pull down on the moisture trap knob Unused air outlet not covered Tightly secure covering cap on unused air outet Leak in air hose or a poor Check all connections and air connection hoses for potential leaks Compressor does not start Defective pressure switch Have pressure switch replaced when pressure is below by specialist wo...

Page 17: ...ig zijn dan stelt de fabrikant zich niet aansprakelijk voor eventuele schade of ongevallen De compressor is ontworpen voor de op het typeplaatje vermelde bedrijfsspanning en mag uitsluitend op een correct geïnstalleerde en gezekerde contactdoos worden aangesloten De spanning moet overeenstemmen met de op het etiket met technische gegevens aangegeven spanning De contactdoos waarop de compressor wor...

Page 18: ...brushspuiten Neem tevens het volgende in acht Tot het beoogd gebruik behoort ook de correcte verwijdering van de gebruikte bedrijfsmiddelen in overeenstemming met de voorschriften Elk ander dan het in deze handleiding beschreven gebruik geldt als oneigenlijk Voor eventuele con sequenties hiervan draagt de gebruiker de volle verantwoordelijkheid Het is niet toegestaan de compressor constructief te ...

Page 19: ...n m b t goede handelskwaliteit of geschiktheid voor een bepaald doeleinde Voor de eerste ingebruikname Het apparaat uitpakken Controleer direct na het uitpakken of de compressor geen transportschade vertoont Indien dit het geval is neem het apparaat dan a u b niet in gebruik en richt u tot uw verkoper Verzeker u ervan dat de netspanning overeenstemt met de op het typeplaatje aangegeven spanning vo...

Page 20: ...ssor bouwt zijn werkdruk op en stopt automatisch als de maximumdruk is bereikt Wordt de com pressor lucht ontnomen en onderschrijdt de luchtdruk in de compressor 40 PSI 2 8 bar dan start de compressor weer tot hij zijn maximumdruk opnieuw heeft bereikt Werkdruk instellen De gewenste werkdruk kan aan de drukregelaar met ingedrukte hendel aan het airbrushapparaat worden ingesteld De werkdruk wordt o...

Page 21: ...wanneer de motor niet loopt Dit is het geval als de motor de maxima le druk heeft opgebouwd en automatisch werd uitgeschakeld De motor bevindt zich dan in een stand bymodus en slaat weer aan zodra de druk onder een bepaalde waarde daalt Om de compressor uit te schakelen schakelt u de aan uit schakelaar in de stand 0 uit Maandelijks visuele controle uitvoeren Voer eenmaal per maand een visuele cont...

Page 22: ... onder de waterafscheider met uw vinger naar boven tot al het water is wegge lopen Als u de aftaphendel weer loslaat sluit hij automatisch De tank moet hierbij onder druk staan Technische gegevens Onderstaand vindt u een tabel met de prestatiewaarden van de compressor AC 500 Model Spanning Vermogen Aanzuig Druk Tank Geluids Gewicht vermogen inhoud sterkte netto volt watt liter bar PSI liter dB A 1...

Page 23: ...iten geen druk op Waterafscheider open Waterafscheider sluiten Niet gebruikte luchtuitlaat open Luchtuitlaat sluiten met afdek kap Defecte luchtslang of defecte Alle slangen en verbindingen op verbinding dichtheid controleren Compressor schakelt niet in Drukschakelaar defect Drukschakelaar door een techni als de druk onder het minimum sche servicedienst laten vervan daalt of schakelt niet uit bij ...

Page 24: ... Stekker Kontakt 15 Compressor Kompressor 16 Veiligheidsbeugel Säkerhetsbygel 17 Till frånbrytare Aan uit schakelaar 18 Slang Slang 19 Vridknapp Draaiknop 20 Inlopp Inlaat 21 Filterkåpa Filterhuis 22 Tömningsventil Uitlaatklep 23 Solfjädertandad bricka Waaierschijf 24 Filterelement Filterelement 25 Filterhållare Filterhouder 26 Filterlock Filterkap 27 Tömningsventil Uitlaatklep 28 Filterhölje Filt...

Page 25: ...ulle vara enligt föreskrifterna ansvarar inte tillverkaren för eventuella skador eller olyckor Maskinen är konstruerad för gängse nationell driftspänning och får endast drivas via ett korrekt instal lerat och säkrat uttag Spänningen måste uppfylla den spänning som anges i tekniska data på etiket ten Uttaget som maskinen är kopplad till måste vara lätt att komma åt så att det vid behov alltid går s...

Page 26: ...ör att driva gängse airbrush apparater Vänligen beakta också följande Till avsedd användning hör också korrekt avfallshantering av använda drivmedel All annan slags användning än den som beskrivs i den här bruksanvisningen gäller som icke avsedd Konsekvenserna från detta står uteslutande av användaren för Det är inte tillåtet att ändra kompressorn konstruktionsmässigt Varningsinformation I den här...

Page 27: ...valitet och lämplighet för ett specifikt syfte gäl ler utöver den här angivna garantitiden Före första användningen Packa upp maskinen Säkerställ att kompressorn inte har några transportskador direkt efter att den har packats upp Låt bli att använda kompressorn om den har transportskador och vänd dig till din handlare Säkerställ att nätspänningen motsvarar spänningsangivelsen Voltage på typskylten...

Page 28: ...ompressorn ska par arbetstrycket och stoppar automatiskt när maxtrycket har uppnåtts Tas luft från kompressorn och lufttrycket i kompressorn underskrider 40 PSI 2 8 bar startar kompressorn tills maxtrycket har upp nåtts igen Ställa in arbetstryck Det önskade arbetstrycket kan ställas in med tryckreglaget Spaken på airbrushmaskinen är tryckt Arbetstrycket visas på manometern 1 Dra vridknappen uppåt...

Page 29: ...inte Detta är fallet när motorn har skapat maximalt tryck och automatiken har kopplat Motorn är i ett standbyläge och går igång direkt igen när trycket faller under ett visst värde För att koppla från kompressorn kopplar du till frånbrytaren till läge 0 från Visuella kontroller varje månad Genomför en visuell kontroll av kompressorn en gång i månaden Var extra observant på anslutningar och skruvar...

Page 30: ...ngsspaken under vattenavskiljaren uppåt med fingret tills allt vatten har kommit ut När du släpper avtappningsspaken igen stängs den automatiskt Det måste finnas tryck i tanken Tekniska data Nedan finns en tabell med prestandavärdena för kompressorn AC 500 Modell Spänning Effekt Insugnings Tryck Tank Buller Vikt effekt innehåll nivå netto Volt Watt liter bar PSI liter dB A 1m kg AC 500 220 240 50 ...

Page 31: ...ck öppen Vattenavskiljaren öppen Stäng vattenavskiljaren Ej använt luftutlopp Stäng luftutloppet öppet med en plugg Defekt luftslang eller Kontrollera alla slangar och defekt förbindelse förbindelser med avseende på täthet Kompressorn slås inte på Tryckbrytare defekt Låt en specialverkstad när trycket är under minimum byta tryckbrytare eller stängs inte av vid maximalt tryck Varning Låt inte kompr...

Page 32: ...Vertrieb über Harder Steenbeck GmbH Co KG Hans Böckler Ring 37 22851 Norderstedt Deutschland www sparmaxair de Art Nr 91047 EAN Code 4039868005397 ...

Reviews: