SPARES ZONE UBWC260 Operation Manual Download Page 8

 

8

 

Not  cold  enough 

temperature inside 

 

 

 

 

Bad ventilation; 

 

 

 

Fans don’t work; 

 

 

The door is not closed tightly 

or  opened  too  frequently  or 

for too long time; 

 

Place  the 

wine  cooler

  in  the  area  with 

good ventilation and keep things away 

from the fans; 

 

Check  whether  the  plug  is  connected 

or change the fan; 

 

Close the door tightly and don’t open 

the door too frequently or for too long 

time. 

Peculiar  smell  inside 

wine cooler

 

●   

Check  whether  there  is  any 

sour inside 

   

Wrap the source or take it out 

Inside light flash 

 

Set  temperature  higher  than 

inner temperature; 

 

The 

automatic 

defrost 

function start to work 

 

Adjust the adjustor 

 

 

Normal function. No repair needed 

Frost on the cold sink 

   

Too much humidity or too low 

temperature inside the case 

   

Output the plug, stop the power, and defrost 

by hand, 

Connect power again when the ice 

thaws 

 

 

Summary of Contents for UBWC260

Page 1: ...1 THERMOELECTRIC WINE COOLER Model No UBWC260...

Page 2: ...on Manual Index I General Safety Precautions 3 II Technical Data 4 III Illustrated Structure 4 IV Electric Principle Diagram 5 V Operation 5 VI Particular Precautions 6 VII Maintenance 6 VIII Troubles...

Page 3: ...ion medical dilution gasoline oil or any other kind of chemical substance that could damage the wine cooler Do not use the appliance if the plug the mains cord or the appliance itself is damaged If th...

Page 4: ...Dimension W D H mm 300x535x660 Net Weight Kg 12 4 Gross Weight Kg 13 4 Power Consumption KW h 24h 0 80 15 C Fitting ambient temperature range of working 32 C Temperature Range 11 C 18 1 C Base on 25...

Page 5: ...2 Fan Mask 3 Chrome Shelf 4 Foot 5 Hinge cover 6 Magnetic Seal 7 Door 8 LIGHT 9 C F button Change from Celsius to Fahrenheit 10 LED Display 11 Temperature UP 12 Temperature Down IV ELECTRIC PRINCIPLE...

Page 6: ...be work normally When the inside temperature lower than the setting point cooling system stop working And the inside temperature will rise When it raises above the setting point Cooling System starts...

Page 7: ...o not use soap or detergent for the cabinet Clean the cellar regularly VIII TROUBLESHOOTING Symptoms Possible cause Solutions No cooling Plug not put in Low voltage Fuse broken Put in the plug Ensure...

Page 8: ...tightly and don t open the door too frequently or for too long time Peculiar smell inside wine cooler Check whether there is any sour inside Wrap the source or take it out Inside light flash Set temp...