background image

ADJUST SET TEMPERATURE POINT

(

) or

(

)

UP

DOWN

The SpaNET intelligent software constantly monitors
the spa water, automatically controlling the heater
and circulation pump to ensure the desired set water
temperature is maintained. The user can adjust the
set temperature point from 5 C - 41 C in steps of
0.2 C increments (Default: 38 C).

1)

the

button. The set temperature point will begin
adjusting up or down in 0.2 C increments.

2) Once the desired set temperature is displayed

press the

(

) button to confirm selection.

The XS-4000 features an integrated countdown
timer that enables the user to set an audible alarm to
sound after a user determined period (5-60 minutes).
The timer will count down the selected period and
show minutes and seconds remaining on the LCD as
it does. The timer icon (

) will be displayed in the

top right of the LCD screen whilst the timer is
running. Once the countdown time has elapsed the
topside panel will beep for one minute or until a
button is pressed.

1) Press the

(

) or

(

) button to

toggle the screen to the

(

) display mode.

2) Press

(

) to select desired time period.

o

o

o

o

o

To adjust the set temperature point:

To start the countdown timer:

Press and hold

OK

COUNTDOWN TIMER

UP

DOWN

TIMR

OK

Notes: 1) If the optional in-pool temperature sensor is fitted
the heater works off a 0.5 C hysteresis (thermostat). The
heater will raise the water to the set temperature point but
thereafter will not be re-activated until the water
temperature falls by at least 0.5 C. Therefore if the spa
user selects a set temperature point of 38 C the actual
water temperature will be anywhere between 37.5 C - 38 C
depending on when the user checks the temperature.

2) If the standard in-heater temperature sensor is used (i.e.
no optional in-pool temperature sensor fitted) the heater
works off a 2 C hysteresis (thermostat). The heater will
raise the water to the set temperature point but thereafter
will not be re-activated until the water temperature falls by
at least 2 C.Therefore if the spa user selects a set
temperature point of 38 C the actual water temperature will
be anywhere between 36 C - 38 C depending on when the
user checks the temperature.

NOTE: The pump(s), blower and light

time-out periods are NOT adjusted by the minute timer.

o

o

o

o

o

o

o

o

o

o

3) Press the

(

) or

(

) button to

adjust the timer in minute increments until the
desired time period is selected.

4) Press

(

) to confirm and begin countdown

For convenient user reference and to assist in
filtration & sleep time functions, your spa controller
includes a built-in real time clock. The user can
choose to display the time in either 12 or 24 hour
format. For ease of reference the current time and
day is displayed at the bottom left of the LCD
screen.

1) Press the

(

) or

(

) button to

toggle the screen to the

(

) display

mode.

2) Press the

(

) button to enter set time

adjustment.

3) Press the

(

) or

(

) button to

select the time format (12 or 24 HR). Press
the

(

) button to confirm selection.

4) Press the

(

) or

(

) button to

modify the weekday (Mon - Sun). Press the

(

) button to confirm selection.

5) Press the

(

) or

(

) button to

modify the hour. Press the

(

) button to

confirm selection.

6) Press the

(

) or

(

) button to

modify the minutes. Press the

(

) button

to confirm selection.

UP

DOWN

OK

.

CLOCK

UP

DOWN

TIME

OK

UP

DOWN

OK

UP

DOWN

OK

UP

DOWN

OK

UP

DOWN

OK

To set the clock:

XS-4000 Quick Reference Guide

OK

Buttons:

1.
2.
3.
4.

Pump A
Pump B
Pump C
Pump D

5.
6.
7.
8.
9.
10.
11.
12.

Indicator Lights

13.
14.
15.
16.

UP
OK
DOWN
Air Blower
One-Touch Sanitise

Light (On / Mode)
Light (Speed / Colour)
Invert Display 180

Auto Mode LED
Element On LED
Ozone/UV On LED
Sleep Cycle LED

o

DISPLAY MODES

UP

DOWN

LED INDICATOR LIGHTS

The XS-4000 topside panel features a large LCD
screen which displays three items: (1) Actual Water
Temperature (2) Set Temperature Point (3) Time &
Day. By default the actual water temperature is
displayed in the large digits (refer below).

There are four possible items that can be displayed
in the large digits: (1) Actual Water Temperature
[W.TMP]*; (2) Set Temperature [S.TMP];
(3) Countdown Timer [TIMR]; (4) Time Clock [TIME].

Press the

(

) or

(

) button to scroll

through these different display modes. As you scroll
through each item a brief title screen will be shown
followed by the actual display mode (note change in
icon).

Each display mode has a unique icon shown at the
top of the screen to indicate the current item being
viewed (refer below).

Note: There is a ten (10) second timeout on viewing non
default display modes. If no button press is sensed after 10
seconds the screen will return to the default display.

The AUTO LED indicator turns ON when

The Heater LED indicator turns ON when
the heater element is active.

The Ozone LED indicator turns ON when
the ozonator / UV sanitiser is active.

The Sleep Cycle LED indicator turns ON when
in a designated sleep cycle (if programmed).

the filtration pump is in automatic mode.

AUTO

O

3

zZz

SA SU

TU WE TH FR

MO

SET TEMP

SETTEMP

°C

°F

°C

°F

°C

°F

MODE

SPD

BRT

MODE

SPD

BRT

OFF

ON

AM

PM

AM

PM

10:30

38.0

Actual

Water Temp

W.TMP Display Mode Icon

Time & Day

Set Temp Point

W.TMP Water Temperature*

S.TMP Set Temperature

TIMR

Countdown Timer

TIME

Clock

* Default Display

OK

OK

OK

OK

OK

OK

OK

Safety Notes:

The appliance must be supplied through a

residual current device (RCD) having a rated residual
operating current not exceeding 30mA.

The appliance must be connected to a suitably rated and
weather protected power supply. The supply line should be a
dedicated power circuit and means for disconnection must
be incorporated in the fixed wiring in accordance with your
local wiring regulations. Means for disconnection from the
supply mains should have a contact separation in all poles
that provide full disconnection under overvoltage category III
conditions.

This appliance is

not intended for use by young children or infirm persons
without supervision.

I

I

I

I

OK

I

SPD/

CLR

1

2

3

4

9

8

5 6

7 11

12

13

14

15

16

10

AUTO

O

3

zZz

NOTE:

www.spanet.com.au/XS_support.html

For complete user manual please log on to

and

download PDF version from the User Manual link.

Reviews: