SV Series

 Spa Controls 

1

 

 

Water Priming Mode

 

 

 

 

 

 

 

 

 

 

Purge air from plumbing system 

 
 
 

             TIPS ON FILLING SPA 

 

 

Before filling remove spa skirt and be sure that all valves in the plumbing 
system are fully open to maximise the amount of air that can escape the pipe 
work during filling 

 

 

Remove filter cartridge(s) before filling and be sure to fill the spa through the 
filter itself to flood the pipe work with water and minimise the chance of air 
pockets forming in the plumbing during the filling process.  

 

 

DO NOT fill spa by placing hose in the foot well. Filling a spa this way will create 
a large number of air pockets in the pipe work and may cause difficulty when 
priming. Always fill spa through the filter area.  

 

 

Once the spa is filled to the correct level attempt to power up the spa with the 
filter cartridges still removed. Verify that the spa controller completes its 
priming sequence and begins normal operation. Once normal operation has 
been verified turn mains power off, re-install filter cartridge(s) and restart spa. 

 

 WARNING 

 
RESTRICTION OF WATER FLOW DUE TO DIRTY FILTER CARTRIDGES IS THE MOST 
COMMON CAUSE OF ER-3 FAULTS. 

IF THE SPA POOL HAS BEEN OPERATING 

NORMALLY THEN INTERMITTENT ER-3 FAULTS START TO OCCUR THE FILTER 
CARTRIDGE(S) WILL REQUIRE SERVICING. 
 
DEPENDING ON TYPE OF FILTER CARTRIDGE(S) INSTALLED THE FILTERS WILL EITHER 
REQUIRE CLEANING, SOAKING IN A FILTER CARTRIDGE DEGREASER SOLUTION OR 
REPLACING. REFER TO SPA RESELLER / MANUFACTURER FOR DETAILS ON TYPE OF 
CARTRIDGE INSTALLED AND RECOMMENDED CLEANING FREQUENCY & METHODS. 
 

Every time the power is turned on the SV controller will initiate a water priming 
sequence on start up. During a priming sequence the filtration pump will run for up to 20 
seconds at a time in an attempt to purge air from the plumbing. The keypad display will 
scroll PRIMING during this sequence.  
 
If the spa controller is successful in clearing all of the air from the heater tube the system 
will begin normal operation. However if air is still detected the spa controller will shut 
down and latch on fault code (ER3-Water Prime).  
 

     How do I solve ER-3 WATER PRIME: 

 

Press Pump A                  button to retry water priming sequence 

 

Check spa is filled to correct operating level as advised by spa manufacturer 
(refill if necessary) 

 

Remove filter cartridge(s) and retry water prime 

 

With mains power turned OFF, bleed airlock from pipe work by slightly 
loosening couplings on front of filtration pump and allowing air to escape 

 

With filter cartridge(s) removed use hose to flush water down pipe work in an 
attempt to clear the air pockets from the plumbing 

 

  

IMPORTANT NOTE 

 
Do not allow the filtration pump to continue to run after five (5) x failed priming attempts. 
Operating a pump without water for extended periods may cause damage to the pump. 
Turns power off, wait ten (10) minutes and then try again later.  
 
The in-heater water sensor constantly monitors the presence of water in the heater tube. If 
at any time air bubbles are detected the spa controller will automatically cancel all current 
operations and force a water priming sequence to begin. This will occur whether the spa is 
in automatic mode or manual use. If the priming sequence is successful in clearing the air 
pockets from the plumbing normal spa operation will resume in automatic mode. If 
unsuccessful the spa controller will shut down and latch on fault code ER-3 Water Prime. 

Summary of Contents for SV4

Page 1: ......

Page 2: ...ontroller will initiate a water priming sequence on start up During a priming sequence the filtration pump will run for up to 20 seconds at a time in an attempt to purge air from the plumbing The keypad display will scroll PRIMING during this sequence If the spa controller is successful in clearing all of the air from the heater tube the system will begin normal operation However if air is still d...

Page 3: ...cking the heartbeat LED on the front of the spa pack itself ER 2 HEATER PLUG Problem No heater sensor communication Cause Internal heater sensor communication problem Solutions Turn mains power OFF wait 5 minutes then restart spa Contact spa reseller if problem is not resolved with power reset ER 3 WATER PRIME Problem Water prime failed air detected in heater tube Cause Airlock in pipe work low wa...

Page 4: ...d Systematically unplug lights in pool temp sensor keypads and expansion port loads from spa pack one by one to identify faulty part Contact your spa reseller if problem persists ER 8 CTRL FAULT HVS Problem Heater relay is on when it should be off Cause Power surge periods of low or high voltage water on spa pack terminal block relay problem Solutions Turn mains power OFF and back ON again to see ...

Page 5: ...at exchanger thermal cut out open IMPORTANT NOTE If a heat pump encounters an error the heat pump will remain disabled until the mains power to the SV spa controller is turned OFF and back ON again The heat pump warning message will continue to scroll every 60 seconds until the power is reset Maintenance Timers SERVICE REMINDER MESSAGES Certain spa manufacturers will choose to take advantage of th...

Page 6: ...etails Spa Net Pty Ltd Unit 4 103 Railway Road North Mulgrave NSW 2756 Australia Phone 61 2 4587 7766 Fax 61 2 4587 8766 www spanet com au Technical Support Service service spanet com au Accounts Department accounts spanet com au Sales Department sales spanet com au ...

Reviews: