5. DIP

 

Switches

 

Settings

Total 6 bits in the DIP switches can be configured. The switches can be 
modified either before or after installation.

1 2 3 4 5 6

ON

DIP

ON

ON

ON (1)

OFF (0)

=

=

6. Electric Lock Connection

12V 300mA

+

-

Jumper position in 2-3

NO NC COM GND GND OPEN

CN3

Exit button

12V 300mA

+

-

Jumper position in 1-2

NO NC COM GND GND OPEN

CN3

Exit button

Power ON to open 

Power OFF to unlock type

1 2 3

SIP1

1 2 3

SIP1

Electric control lock

Magetic lock

Bit-1

,

Bit-2

 

and

 

Bit

-

3 are used for door station ID 

setting(1=on,0=off).

Bit-1

,

Bit-2

 

and

 

Bit

-

3 are used for door station ID 

setting(1=on,0=off). 
000

 - 

100

 - 

010

 - 

110

 - 

001

 - 

101

 - 

011

 - 

111

000

 - 

First

 

door

 

station

100

 

Second

 

door

 

station

010

 - 

Third

 

door

 

station

110

 - 

Fourth

 

door

 

station

Bit-4 and Bit-5 is used for unlock time setting. 
00 - 1

 

second

 (

Default

 

setting

)

10

 - 

5

 

seconds

01

 - 

10

 

seconds

11

 - 

15

 

seconds

Bit

-

6

 

is

 

used

 

for

 

connecting

 

extra

 

camera

.

0 - No extra camera (Default setting)
1 - Connecting  with extra camera

1. The door lock power for a 12v DC strike (max current=250mA).

2. For Electric control lock, setting the jumper SIP1 to 2-3 for a normally
open lock (power ON  to open);

For electromagnetic lock  or magnetic lock,need set SIP1 to 1-2 for a 
normally closed lock(power OFF to open)

3. Adjust the timer setting with Bit-4 and Bit-5 at the outdoor station

(1=on,0=off)

00-1sec, 01-5sec,10-10sec,11-15sec.

-6-

Summary of Contents for DIO SPD-DS81 Series

Page 1: ...Door Station SPD DS81x User s Manual Please read this manual carefully before using the product ...

Page 2: ... button Microphone Light sensing touch button When any object blocks the button the button can be triggered Which solved the problem that the capacitive touch button cannot trigger the button when people wear gloves Alex Press down and move left to open the transparent nameplate cover Then insert the name paper and put the cover back 1 ...

Page 3: ... 2 3 are used for NFC command selection Long press the switch for 2 seconds to set 100 Make a master card 000 Use IC card encryption mode password fixed 111 Use IC card without encryption mode 010 Delete a IC card or key tag 001 Format all the IC cards or key tags BUS L1 L2 non polarity bus line 2222222 NFC Swipe the IC card to open the door Swipe a user card to hear a long beep the door opens Swi...

Page 4: ...master card will hear a beep every second and swipe a new user card within 60 seconds hear a long beep again and enter successfully then swipe an old user card hear a short beep three times delete it successfully and finally swipe the master card to exit It can support up to 2990 user cards Using IC card encryption mode password fixed The DIP switch is set to 000 Press the DIP switch for 2 seconds...

Page 5: ...o the rainy cover correctlly The last view for all mounting Router Power supply UTP5E UTP5E IP Module Multi door station connection N NC L Input 100 240V Power Supply Model 206A 2S Output 26V 2V Max 7A Bus IM Bus DS Power Supply N NC L Input 100 240V Power Supply Model 206A 2S Output 26V 2V Max 7A Bus IM Bus DS Power Supply 4 ...

Page 6: ... A 7 ON DIP 6 1 2 3 4 5 1 ID 000 When monitor quantity 20 Cable Usage 2 Parallel cable 2x0 75mm A 60 80 B 60 80 30 40 2 Parallel cable 2x1mm C When monitor quantity 20 Cable Usage A 60 80 B 60 80 C 30 40 2 Parallel cable 2x1 5mm 2 Parallel cable 2x1mm 1 Door station when there is only one Door station the DIP bit 1 bit 2 and bit 3 should be set to 000 2 Power supply MUST be installed side by side ...

Page 7: ...ion ID setting 1 on 0 off 000 100 010 110 001 101 011 111 000 First door station 100 Second door station 010 Third door station 110 Fourth door station Bit 4 and Bit 5 is used for unlock time setting 00 1 second Default setting 10 5 seconds 01 10 seconds 11 15 seconds Bit 6 is used for connecting extra camera 0 No extra camera Default setting 1 Connecting with extra camera 1 The door lock power fo...

Page 8: ...wer Consumption 1W in standby 5W in working Unlock Power output 12Vdc 250mA Unlock timing 1s 5s 10s 15s Working Temperature 20 55 Power supply DC 24V The WEEE symbol the crossed out wheeled bin using indicates that this product is not home waste Appropriate waste management aids in avoiding consequences which are harmful for people and environment and result from dangerous materials used in the de...

Reviews: