A variety of options exist to secure materials stored on the system.

TouchPad Aisle Access 

requires a 4-

digit Personal Identification
Number (PIN) to access a specific
aisle, limiting it only to authorized
individuals.  Upon exiting the open
aisle, the user must depress the
“Close” button on the system
module to re-secure the system.
One or all of the carriages may have
this control in place of the standard
or infrared-capable control.

TouchPad System On/Off 

is used

in addition to the standard control
and functions as follows. When
placed on a platform, it can be
used to turn the system on and off.

TouchPad Stationary Control 

is used in addition to the

standard control and functions in the following ways to create a
stationary carriage within a powered system.

•  Install the TouchPad Stationary Control on the extreme

left (or right) carriage. Park the carriages to the right (or
left). Enter the preset code and the system will remain
locked in that configuration (back lighting on the control
will indicate “Stationary Carriage”) until the code is
entered once again, allowing normal operation to resume.

•  Install the TouchPad Stationery Control on any carriage

within the system. Park that carriage in the desired
location. Enter the preset code and the carriage will remain
locked in that position (back lighting on that control will
indicate “Stationary Carriage”) until the code is entered
once again, allowing normal operation to resume.

In all these situations, a 4-digit PIN is required.  The following
procedure allows you to program the TouchPad control with
your own 4-digit code. This programming must take place
within a 10-second interval.  NOTE:   The factory-default code
is 1-2-3-4.  

To change the 4-digit PIN;
1.  Press the “#” key, then press the “*” key.  The green

LED will being to blink.

2. Enter in the 

current

code within the 10 seconds allotted.

Once the current code is entered, the LED will flash red.

3.  Enter in the 

new

code within the 10 seconds allotted.

4.  The solid green LED will return.

Keyed System On/Off

turns the entire system on and off with

a key located above the control.

Security

8

Summary of Contents for Eclipse Powered System

Page 1: ...Eclipse Powered System OWNER S MANUAL...

Page 2: ...ructions 3 Control Functions 4 System Operation and Reset Options 4 Control Options 5 Safety 6 Optional Safeties 7 Security 8 Programmable Options 10 Power Outage Options 11 Lighting Options 12 Troubl...

Page 3: ...mmended shelf loading instructions found in this section of the owner s manual 5 Keep media neatly stored and pushed fully back onto the shelving to help maintain desired aisle width 6 Provide needed...

Page 4: ...or system access programming See the Control Options section of this manual for more information on this feature System Operation and Reset Options Touch Hold Operation Touch hold operation requires t...

Page 5: ...additional functionality when used in conjunction with the infrared capable control System On Off A press of the button will turn the entire system on and off To initiate this function point the remo...

Page 6: ...isplay aisle in use and the control LED will flash red All other controls will go dark Once the safety sweep has been cleared press the Stop Reset button to resume normal system activity Safety Overri...

Page 7: ...nd prevent the system from moving Entering an opening aisle will have no effect on the opening of the aisle but will prevent the system from moving once the aisle is fully opened until the system is r...

Page 8: ...that configuration back lighting on the control will indicate Stationary Carriage until the code is entered once again allowing normal operation to resume Install the TouchPad Stationery Control on a...

Page 9: ...ert the key into the lock and rotate the key 180 degrees to lock or unlock Rotate the polished chrome handle turn to engage or disengage the lock It can be used to lock all of the system s aisles clos...

Page 10: ...system left or right System Ventilation Park Opens the system at evenly spaced intervals System Auto Cycle Opens each aisle in sequence During automatic move functions all safety features are fully fu...

Page 11: ...ry backup provides the added benefit of surge protection When the system is back running on AC power the unit automatically recharges itself The Power Override Unit is a hand held rechargeable battery...

Page 12: ...Options CONTROL INDICATION Abnormal Carriage Movement Controls on both sides of the open aisle display Aisle in Use and the LED is flashing red None of the controls work None of the LED s are lit All...

Page 13: ...oblems Laminate Panels To clean and restore the surface apply a countertop or laminate cleaner found at most hardware stores Metal Surfaces All metal surfaces are painted with the powder coat system T...

Page 14: ...warranty shall be void if any portion of the purchase price shall be due but unpaid in accordance with the terms pursuant to which the equipment was sold This warranty shall not apply to equipment re...

Page 15: ...t any type of material regardless of its size weight or shape can be stored in Spacesaver Powered Systems Designed to maximize your storage space they often more than double storage capacity in the sa...

Page 16: ...age Systems Modular Mobile Systems Modular Bi File Systems QuickSpace Systems Mobile Art Rack Systems Hang Glider Pro Pullout Storage Panel Systems Rotary Storage Systems Cantilever Bookstack Systems...

Reviews: