P
: STOP 1—L
T
P
Probable Cause
1. Viscosity adjustment is set
incorrectly.
2. Inadequate mix in hopper.
3. Improper mixing of product.
4. Air tube isn’t installed correctly.
5. Product is being drawn too
quickly.
P
: STOP 2—M
O
P
: STOP 4—T
Probable Cause
1. Inadequate mix in hopper.
2. Improper mixing of product.
3. Air tube isn’t installed correctly.
4. Viscosity adjustment is set
incorrectly.
5. Product is being drawn too quickly
Probable Cause
Malfunc oning temperature probe.
P
: STOP 6—M
A
Remedy
Replace power board.
Remedy
1. Ensure hopper is at least half full.
2. Follow manufacturer instruc ons for
mixing product; ensure correct mix ra os.
3. Clean air tube, ensure proper orienta on.
4. Lower viscosity se ng as required.
5. Ensure air tube isn’t clogged, allow
machine 2 to 5 seconds between servings.
Remedy
1. Ensure hopper is at least half full.
2. Lower viscosity se ng as required Follow
manufacturer instruc ons for mixing
product; ensure correct mix ra os.
3. Clean air tube, ensure proper orienta on.
4. Ensure air tube isn’t clogged, allow
machine 2 to 5 seconds between servings
to recover.
Remedy
Replace temperature probe.
Probable Cause
Malfunc oning power board.
17
P
: STOP 3—M
P
Remedy
1. Install the dispensing door.
2. Check and reinstall jumper on display
board.
Probable Cause
1. Dispensing door is o
ff
.
2.
Jumper on display board is
disconnected or loose.
T
P
: H
'
Probable Cause
1. Inadequate mix in hopper.
2. Hopper temperature se ng is too low.
Remedy
1. Ensure hopper is at least half full.
2. Adjust hopper temperature warmer (Page 16).
P
: P
P
: P
P
: P
Probable Cause
1. Improper or inadequate lubrica on of drive
sha seal.
2. Damaged, missing, or improperly installed drive
sha seal.
Remedy
1. Use su
ffi
cient food-grade lubricant, and add
su
ffi
cient lubricant inside drive sha gasket
during assembly (Page 9).
2. Replace drive sha gaskets every 1 to 3 months.
Probable Cause
1. Improper or inadequate lubrica on of draw
valve and draw valve O-rings.
2. Cracked, broken, or worn draw valve O-rings.
Remedy
1. Use su
ffi
cient food-grade lubricant when
assembling draw valves (Page 10).
2. Replace O-rings every 1 to 3 months.
P
: M
S
A
Probable Cause
1. Machine isn’t cleaned/lubricated adequately.
2. Inadequate mix in hopper.
3. Improper mixing of product.
4. Machine doesn’t have adequate ven la on.
5. Viscosity adjustment is set incorrectly.
Remedy
1. Clean and properly lubricate machine daily.
2. Ensure hopper is at least half full.
3. Follow manufacturer instruc ons for mixing
product; ensure correct mix ra os.
4. Ensure at least 152mm (6'') clearance on all
sides.
5. Raise viscosity se ng as required (Page 16).
Probable Cause
1. Warm product was recently added.
2. Hopper temperature se ng is too high.
3. Temperature o
ff
sets need adjustment.
Remedy
1. Allow at least 1 hour a er adding new mix for
hopper temperatures to stabilize.
2. Adjust hopper temperature warmer (Page 16).
3. Call Spaceman Technical Support.
P
: H
Probable Cause
Cylinders are experiencing freeze-up (usually due
to viscosity being set too high for selected
product).
Remedy
Reset machine (Page 14), and lower viscosity as
required (Page 16).
P
: M
Probable Cause
1. Improper assembly.
2. Wearable parts need replacement.
3. Internal cleaning/maintenance required.
4. Damaged internal parts.
Remedy
1. Stop machine use, drain product with machine
powered OFF; clean and inspect parts.
2. Replace wearable parts (including scraper
blades) at least once every 3 months.
3. Contact Spaceman Technical Support.
4. Inspect parts carefully for damage, ensure
proper assembly; replace as required.
18
T