64
SM2204 - SM2206 - SM2208
0525-M005-2-P1
11
11.2 IMPIANTO ELETTRICO QUADRO PRINCIPALE
11.2 WIRING DIAGRAM MAIN BOARD
11.2 ELEKTRISCHEN ANLAGE - HAUPTSCHALTTAFEL
11.2 INSTALLATION ELECTRIQUE - TABLEAU PRINCIPAL
11.2 INSTALACIÓN ELECTRICA CUADRO PRINCIPAL
94
93
92
23
22
22
22
22
22
SCHERMO
BIANCO
MARR.
3
CNF1
2
CNF1
1
CNF1
51
O 1 BIANCO/ROSSO
O Ø BIANCO/NERO
52
10
10
DD
DDD
DD
D
D
D
D
D
SCHERMO
BIANCO
MARR.
87
6
54
3
21
D
94
93
92
19
61
61
L2
K1
16
16
16
25
15
15
15
24
24
25
10
10
BLU
MARR.
20
FCP
19
69
70
143
142
58
144
144
142
143
PS
PD
FCD
55
56
57
62
54
53
143
142
KL
P1
4
CNF1
6
CNF1
O Ø BIANCO/NERO
CNF3
20
CNF4
20
20
CNF2
CNF4
19
16
CNF3
16
CNF4
16
CNF2
15
CNF3
15
CNF4
15
CNF2
9
CNF2
CNF3
9
CNF4
9
62
SALITA PULSANT.
DISCESA PULSANT.
A
4
3
2
1
SC
19
B
10
ROSSO
NERO
R4
R1
R2
R3
0
+24
1
2
26
25
7
6
5
4
3
2
1
0
IN
DC
Tr.OUT Sce
9
8
7
6
5
4
3
2
1
0
11
10
ERR
RUN
STAT
FLAT
PWR
BIANCO/GRIGIO
62
BIANCO/ROSA
BIANCO/GIALLO
BIANCO/VERDE
GRIGIO/ROSA
BIANCO
VERDE
10
10
10
10
GRIGIO
BLU
BIANCO/BLU
BIANCO/ROSSO
BIANCO/NERO
CNF2
14
142
CNF3
14
143
CNF4
14
144
19
19
19
19
19
10
19
10
NERO
ROSSO
MARR./NERO
MARRONE
10
GIALLO
10
20
ROSA
ROSSO
VIOLA
204
204
203
203
202
202
ROSSO/BLU
MARR./ROSSO
MARR./BLU
D
D
D
17
17
17
26
26
17
CNF3
17
CNF4
17
CNF2
ROSA/MARR.
D
D
18
18
18
27
18
CNF3
18
CNF4
18
CNF2
27
MARR./VERDE
19
PD
15
CNF1
KL
65
CNF2
22
CNF3
22
CNF4
22
K3
64
22
K2
GIALLO/MARR.
GRIGIO/MARR.
23
51
O 1 BIANCO/ROSSO
O 2 BIANCO/BLU
O Ø BIANCO/NERO
O 1 BIANCO/ROSSO
O 2 BIANCO/BLU
D
10
PLC
I.Ø
I.1
I.2
I.3
I.4
I.5
I.6
I.7
I.8
I.9
I.10
I.11
com.I
O.Ø
O.1
O.2
O.3
O.4
O.5
O.6
O.7
24VDC
24VDC
24VDC
ØVDC
ØVDC
D
CNF4
10
CNF1
7
2
1
0
TR
400
0
230
18
0
0
24
3
M
10
21
21
21
21
21
19
19
10
10
FU6
K2
63
21
K3
10
19
19
CNF2
CNF3
19
19
21
21
23
PS
FCS
13
CNF1
KL
73
CNF2
21
CNF3
21
CNF4
21
CNF2
23
CNF3
23
CNF4
23
10
19
CNF3
10
CNF2
10
giallo/verde 6mmq
giallo/verde 1mmq
giallo/verde 2.5mmq
nero 2.5mmq
nero 2.5mmq
nero 1.5mmq
nero 10mmq
rosso 1mmq
rosso 1mmq
marrone 1mmq
blu 1mmq
L3
L2
L1
FU1
U1
V1
W1
W1
V1
U1
KD
KS
KS
KD
43
39
41
37
FCS
FCD
41
37
40
36
K1
K1
11
12
11
11
12
8
8
8
8
8
8
66
66
66
72
71
71
59
60
7
46
45
K2
K3
13
68
68
67
K4
KL
K4
K5
K5
K4
44
44
44
44
3
STM
PEM
L1
13
13
13
13
13
13
13
13
13
KSF
FU5
FU4
4
2
1
PRD
C
CNF1
14
CNF1
11
8
CNF1
CNF4
CNF4
CNF3
CNF3
CNF2
CNF2
11
11
11
CNF4
CNF3
CNF2
CNF4
12
CNF3
12
CNF2
12
8
7
8
7
CNF4
CNF4
CNF3
CNF3
8
CNF2
CNF2
7
13
13
13
CNF3
CNF4
CNF2
CNF3
CNF4
CNF2
CNF4
CNF3
CNF2
5
3
1
5
3
1
5
3
1
12
CNF1
10
9
CNF1
CNF1
R2
S2
T2
R2
FU3
R1
S1
T1
FU2
KL
KS
KD
U0
V0
W0
U0
V0
W0
U0
V0
W0
U0
V0
W0
UV
W
IG
KSF
11
9
2
F
S
RS
T
+
-
EMERGENZA PULSANT.
RIFER.
NOMENCLATURA
MORSETTO
KS
CONTATTORE COMANDO MOTORE IN SALITA
TR
TRASFORMATORE 200VA Vp 0/230/400 Vs 0/18 0/24
KL
CONTATTORE DI LINEA
KD
CONTATTORE COMANDO MOTORE IN DISCESA
STM
TERMOSONDA MOTORE
SC
COMMUTATORE SELEZIONE COPPIE COLONNE
R4
RESISTENZA 1/4W 5,6K
R3
RESISTENZA 1/4W 10K
R2
RESISTENZA 1/4W 15K
R1
RESISTENZA 1/4W 39K
KSF
RELE’ CONTROLLO SEQUENZA FASI
K4/5
RELE’ DI EMERGENZA
K3
RELE’ COMANDO DISCESA
K2
RELE’ COMANDO SALITA
K1
RELE’ COMANDO MOTORE
PS
PULSANTE DI SALITA
PRD
PONTE RADDRIZZATORE
PLC
CONTROLLORE LOGICO PROGRAMMABILE
PEM
PULSANTE DI EMERGENZA A FUNGO
PD
PULSANTE DI DISCESA
P1
PULSANTE GIALLO MOVIMENTO SINGOLO
M
MOTORE
L2
SPIA ROSSA EMRGENZA E BLOCCO
L1
SPIA BIANCA SEQUENZA FASI CORRETTA
IG
INVERTITORE GENERALE 1-0-2 ( 40A )
FU6
FUSIBILE PROTEZIONE 24Vdc PLC 5x20 1A 250V RAPIDO
FU5
FUSIBILE PROTEZIONE SECONDARIO TR (18V) 5x20 4A
250V RAPIDO
FU4
FUSIBILE PROTEZIONE SECONDARIO TR (24V) 5x20 4A
250V RAPIDO
FU3
FUSIBILI PROTEZIONE PRIMARIO TR 10.3x38 2A 500V gl
TERNA FUSIBILI PROTEZIONE LINEA MOTORE
FU2
10.3x38 16A 500V aM (VERS.230V) 10.3x38 10A 500V aM
(VERS.400V)
TERNA FUSIBILI PROTEZIONE LINEA
FU1
14x51 50A 500V aM (VERS.230V) 14x51 32A 500V aM
(VERS.400V)
FCS
FINECORSA SALITA
FCP
INTERRUTTORE DI PROSSIMITA’
FCD
FINECORSA DISCESA
D
DIODO 1N 4003
CNF2/3/4CONNETTORE FEMMINA COLLEGAMENTO COLONNE
SATELLITI
CNF1
CONNETTORE CANNON 15 POLI FEMM.
INTERCONNESS.COL COM.
C
CONDENSATORE ELETTROLITICO 4700 microF 50V
REF.
DENOMINATIONS
-
TERMINAL
KS
RISE CONTROL CONTACTOR
TR
TRANSFORMER 200VA Vp 0/220/380 Vs 0/18 0/24
KL
LINE CONTACTOR
KD
DESCENT CONTROL CONTACTOR
STM
MOTOR HEAT PROBE
SC
POST SELECTION SWITCH
R4
RESISTOR 1/4W 5,6K
R3
RESISTOR 1/4W 10K
R2
RESISTOR 1/4W 15K
R1
RESISTOR 1/4W 39K
KSF
PHASE SEQUENCE CONTROL RELAY
K4/5
EMERGENCY RELAY
K3
DOWN CONTROL RELAY
K2
UP CONTROL RELAY
K1
MOTOR CONTROL RELAY
PS
UP PUSH-BUTTON
PRD
RECTIFIER JUMPER
PLC
LOGIC PROGRAMMABLE CONTROLLER
PEM
EMERGENCY PUSH-BUTTON (MUSH-ROOM SHAPE)
PD
DOWN BUTTON
P1
SINGLE-MOVEMENT YELLOW PUSH-BUTTON
M
MOTOR
L2
BLOCK AND EMERGENCY RED WARNING LIGHT
L1
CORRECT PHASE SEQUENCE WARNING LIGHT
IG
MAIN INVERTER 1-0-2 (40A)
FU6
PROTECTION FUSE 24Vdc PLC 5x20 1A 250V QUICK
FU5
SECONDARY PROTECTION FUSES TR
(18V) 5x20 4A 250V QUICK
FU4
SECONDARY PROTECTION FUSES TR
(24V) 5x20 4A 250V QUICK
FU3
PRIMARY PROTECTION FUSES TR 10.3x38 2A 500V gl
FU2
TRIPLET OF MOTOR LINE FUSES 10.3x38 16A 500V aM
(VERS.230V) 10.3x38 10A 500V aM (VERS.400V)
FU1
TRIPLET OF MOTOR LINE FUSES 14x51 50A 500V aM
(VERS.230V) 14x51 32A 500V aM (VERS.400V)
FCS
RISE LIMIT SWITCH
FCP
PROXIMITY LIMIT SWITCH
FCD
DESCENT LIMIT SWITCH
D
DIODE 1N 4003
CNF2/3/4 FEMALE CONNECTOR TO SATELLITE POSTS
CNF1
CANNON 15-POLE FEMALE CONNECTOR,
INTERCONNSS.
C
ELECTROLYTIC CAPACITOR 4700 microF 50V
Summary of Contents for SM2204
Page 12: ...12 SM2204 SM2206 SM2208 0525 M005 2 P1 2 Kg 4000...
Page 22: ...22 SM2204 SM2206 SM2208 0525 M005 2 P1 1 2 3...
Page 24: ...24 SM2204 SM2206 SM2208 0525 M005 2 P1 4 1 2 3 9 7 NOT AUS 5 8 4 6 6...
Page 28: ...28 SM2204 SM2206 SM2208 0525 M005 2 P1 6 Q R1 R1 Q 4650 kg R1 2000 kg...
Page 44: ...44 SM2204 SM2206 SM2208 0525 M005 2 P1 7...
Page 46: ...46 SM2204 SM2206 SM2208 0525 M005 2 P1 B A B 7...
Page 50: ...50 SM2204 SM2206 SM2208 0525 M005 2 P1 7...
Page 58: ...58 SM2204 SM2206 SM2208 0525 M005 2 P1 9 1 2...