–1– Form
#43219000
Jan 09
!
WHAT TO DO IF YOU SMELL GAS:
!
DO NOT try to light any appliance. Extinguish any open flame. Open windows.
!
DO NOT touch any electrical switch. DO NOT use any telephone in your building.
!
Immediately call your gas supplier from a neighbor’s telephone. Follow the gas supplier's
instructions.
!
If you cannot reach your gas supplier, call the Fire Department.
TABLE OF CONTENTS
SECTION DESCRIPTION PAGE SECTION DESCRIPTION PAGE
1)
General Information ...........................................................
1
8)
Electrical Connections................................................
7
2)
Minimum Clearances To Combustibles ..........................
3
9)
Ventilation....................................................................
8
3)
Hanging ................................................................................
3
10)
Lighting And Shutdown Instructions ........................
8
4)
RSCA Specifications...........................................................
4
11)
Cleaning and Annual Maintenance..........................
9
5)
Optional Parabolic Reflector Extension Assembly ........
4
12)
Replacing
Parts...........................................................
9
6)
Gas Connections And Regulation
..................................... 5
13)
Installation
Data .........................................................
9
7)
Instructions For Pressure Test Gauge Connection.........
6
14)
Replacement Parts Guide .......................................
10
This heater complies with ANSI Z83.19 (current standard) and CSA 2.35. Copies of the National Fuel Gas Code (ANSI Z223.1-latest edition)
are available from the CSA at 8501 East Pleasant Valley Road, Cleveland, Ohio 44131 or 55 Scarsdale Road, Don Mills, Ontario M3B 2R3. All
NFPA codes are available from the National Fire Protection Association, Batterymarch Park, Quincy, Massachusetts 02269.
1) GENERAL INFORMATION
This heater is a self-contained infrared radiant ceramic heater for use in locations where flammable gases or vapors are not
generally present (as defined by OSHA acceptable limits) and is intended for space heating
non-residential spaces
.
SAFETY REQUIREMENTS
!
The heater area must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids.
!
This heater is designed for use with one type of gas (LPG or Natural). Make sure that the type of gas to be supplied to this
heater matches that shown on the heater rating plate.
!
DO NOT
install this heater directly onto an LPG container or propane cylinder without directions from your propane
company. LPG containers (propane cylinders) must not be stored indoors or in the vicinity of any gas-burning appliance.
!
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or
clothing ignition.
!
Clothing or other flammable materials should not be hung from the heater or placed on or near the heater.
!
Young children should be carefully supervised when they are in the same space as the heater.
!
NEVER
attempt to service the heater while it is plugged in, operating or hot. Any guard or other protective device removed
for servicing a heater must be replaced prior to operating the heater.
S
WARNING: NOT FOR RESIDENTIAL USE.
S
WARNING:
♦
Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
♦
If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
♦
DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.