Important:
Before using check that the Spa Pool has been connected to a
suitable weather protected outlet socket and Double Pole
Isolating Switch with ratings as specified on the name plate of
the control box. Do not run this appliance on an extension
lead.
12: LCD Display
2 & 4: Up Down Buttons
3: Set Button
5: Icons
6: Display Button
7: Light Button
8: Pump 2 Button
9: Air Button
10: Mimic Panel
11: Pump 1 Button
The Backlit Liquid Crystal Display can display five different
quantities:
a) The currently sensed pool temperature.
b) The target pool temperature
c) The time of day
d) The sleep start time
e) The sleep finish time
In addition the LCD can also show diagnostic fault codes.
These two buttons are used to adjust the controller settings as
shown on the LCD Display, after pushing the set button.
To make any changes to the stored settings select the setting
required using the display button. The icon and display will
change to indicate your choice. Press the set button and the
display will flash the current value. Adjust to the required value
by pressing the up/down buttons. If you change your mind,
pressing the display button will cancel any changes. To keep
changes press the set button again. The display will always
revert to the water temperature reading after a short time. By
following the above procedure the desired pool temperature can be
set, the time of day and the sleep start and finish times. The time of
day and sleep times will need to be set the first time the controller is
powered up or if it has been turned off for a long period. If the sleep
start = finish time the sleep mode is deactivated.
This Icon is lit by default. When lit the LCD display is
measuring the in pool temperature. For accurate readings it
is advisable to run the pump for several minutes in manual
mode to mix up the pool water.
When lit the desired pool temperature can be adjusted
typically to 37°C (default) or to that which is comfortable.
This Icon indicates that the time of day is being displayed.
Time can be adjusted remembering to set for AM or PM as
indicated on the display 1 .
When lit the display shows the time at which the controller
will start its sleep mode. This is a very handy feature and is
used to silence the spa pool during your hours of sleep.
Typically settings are between 12pm & 7am. The spa can be
used within the sleep hours without having to change any
times by pressing the pump 1 button so that the controller is
in manual mode.
This icon indicates the wake up time from sleep mode. It is
normal for the spa to run for a long period after sleep to
recover temperature lost over night. The time should be set
approx. one hour before a spa is desired.
This indicator is lit when the controller is asleep. Manual
operation will over ride any sleep settings if the spa is
required during the preset hours.
This button cycles through the above icons and LCD displays
allowing viewing or adjustment of the controller’s main settings.
This button controls the pool light. A green LED indicates when the
light is on.
This button controls the booster pump. A green LED indicates
when the pump is on.
The air switch has three modes. Successive pushes select high
speed (red LED), medium speed (orange LED) and blower ramping
up and down in speed (green LED).
Options = 1 speed, 2 speed, 3 speed or 2 speed and ramping
Note:
Note:
Note:
Note:
Note:
There is an automatic timeout of the blower, booster pump and light.
All three will automatically switch off together 30 minutes after the
last push of their respective buttons.
The colours corresponding to the LED
colours displayed on the air switch and
pump 1 can be identified and inter-
preted as to their operating mode.
Pushes of this switch selects the main operating modes of the spa
system.
1/ Auto Mode (red LED) is the default start up mode where the
pump, heating and filtration are automatically controlled.
2/ Manual Mode (orange LED) where the user can control the main
circulation pump even when the system is asleep. The heating will
turn on/off automatically as required. This mode may have two
speeds. The first position is slow speed with the LED flashing and
the second is high speed with the LED constant.
3/ Stand-by Mode (green LED) where the user can turn all Pump 1
functions off for absolute quiet. This mode reverts to auto mode
after a preset time.
Note:
Note:
Note:
Note:
Note:
The manual and stand-by modes will automatically revert to auto
after a factory set time. If additional filtration time for example is
required then pushing the button for manual mode will give an
additional filtration period and allows it to time out by itself back to
auto. There is a time delay of a few seconds between the pump
switching on and the heater turning on, and between the heater
switching off and the pump switching off.