29
SC-CF & SC-MP Service Manual
FLC Flow Chart
If FLC error condition occurs, follow Troubleshooting Flow Chart below to
identify problem (usually pressure switch problem - pump is off but water
pressure is detected):
Disconnect
pressure switch cable
on pressure switch.
Does FLO error condition
occur when pump is on?
Adjust
pressure
switch.
Replace
pressure switch
if FLC error
condition
persists when
you start or
stop pump.
Replace
Spa Pack.
yes
no
Summary of Contents for SC-CF