HIGH PRESSURE OPERATION
Never pull the hose to move the unit. This could damage hose and/or pump inlet.
Never allow pump to run with water hose turned off or kinked. Shutting off the water supply to the pump while
it is operating may cause serious pump damage.
Do not let hoses contact HOT engine muffler during or immediately after use, as this will damage the hose.
Interchangeable Nozzles:
•
Pull back the quick connect lock ring, firmly insert the desired nozzle and then release the lock ring.
•
Make sure the spray nozzle is properly locked in place with its quick coupler, if the collar is not
(Forward) in the locking position, the nozzle may become a dangerous projectile. The O-ring from your
quick coupler socket may also be blown out of place.
(Red) (Yellow) (Green) (White)
Explanation:
0
°
nozzle setting – A pinpoint stream. This nozzle stream is very powerful and covers a very small area of cleaning.
Only to be used on surfaces that can withstand this high pressure (metal or concrete).
15
°
to 25
°
nozzle setting – Used for less powerful stream which can cover a wider area. This nozzle setting is also
very powerful and should only be used on surfaces that can withstand this high pressure.
40
°
nozzle setting – Used for the least powerful stream and covers a wide area of cleaning. This nozzle setting should
be used for most general cleaning jobs.