4
Operation
How to use:
1) Check the battery is suitable for this charger.
2) Select the correct battery voltage by rotating the Voltage selection switch.
3) Connect the charger Positive (Red) Lead to the Positive of the battery.
4) Connect the charger Negative (Black) Lead to the Negative of the battery.
5) Plug the charger into the power socket & turn on the charger.
6) Select the battery type by repeatedly pressing the battery type selector until the
correct type is illuminated on the display.
Gel = Gel Batteries, Lead Acid = Lead Antimony & AGM Batteries, Calcium =
Calcium (Ca-Ca or Ca-Ag)
7) Charging is now taking place.
8) When the battery capacity bar graph is fully lit up, the battery is fully charged & the
charger has gone into its maintenance stage. You can disconnect the charger, or
leave the charger connected, if left connected the charger will maintain the battery in
a fully charged state without causing any damage to the battery or charger.
Note: The charger will remember the last battery type selected, even after disconnection
from the power, and will only change when changed manually by the user. This is very
useful if you are charging a lot of batteries, or the unit is permanently connected to a
battery bank and the 240V power may be frequently disconnected and reconnected.
LED Display:
•
Battery Type Selected – “GEL”, “LEAD
ACID”, “CALCIUM”
•
Charging Voltage – Shows the Voltage
of the battery while charging.
•
All bars on battery will flash if the
charger has determined that the battery
may be faulty.
The battery bar graph will display the percentage of charge in the battery, when all bars
are illuminated the battery is fully charged.
Charge
100%
50%
10%
As well the red & white terminals
on battery bar graph display will
flash, if the charger is connected
to the battery with reverse
polarity.