Soyal Control Systems User Manual Download Page 3

SOYAL

ACCESS CONTROL SYSTEM

®

AR-829E-V5

V120508

    

   

N.C.
N.O.
COM

CTL

12V

E

E

BZ

RLED
GLED

WG 0
WG 1

12V

GND

1

1

1

2

2

2

3

3

3

4

4

4

5

5

5

6

6

6

7

7

7

8

8

8

1
2
3
4
5
6

12V
GND
Exit Switch

12V
GND

12V
GND

12V

GND

12V

GND

12V

GND

PB

PB

COM

COM

N.O.

N.O.

P2

P1

P1

P1

BZ
RLED
GLED
Door Output
WG 0
WG 1
WG-DS
WG-PB

7
8

EXIT

1
2
3
4
5
6
7
8

1   2   3

N.C.
N.O.

COM

CTL
12V

GND

PB

12V

GND

12V
GND

N.O.

12V

GND

12V

GND

DDR

P1

P6

AR-721RB

4

12V

N.C.

EXIT

RTE

EXIT

1
2
3
4
5
6
7
8

12V
GND

12V

GND

PB

COM

N.C.

P1

EXIT

EXIT

Controller 

Controller 

Reader

RTE

RTE

RTE

RTE

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

Electric Strike

Door Contact

Strengthen security with AR-721RB

If any fire emergency, the people can escape by press a switch to open all doors

Electric Bolt

Electric Bolt

Electric Bolt

Fire Emergency

Transistor

IN4007

Transistor

IN4007

Connect to Reader

Magnet Lock

Access programming mode

 →     

Add/Delete

 →    

 Add -> RF-Learn

 → 

Input 5-digit user address

 

→ 

Input Tag Units(pcs) 

 → 

Close Tag into RF Area

If a batch of tags are 

Sequential

, input Tag Units(pcs) in the quantity of the tags and present the tag with   

    the 

lowest number

 to the controller.

1

2

Adding Tag by RF Learn Function

Tag Information

SITE CODE

CARD CODE

SITE CODE

CARD CODE

Adding and Deleting Tag

※ 

User capacity: 16384 (00000~16383)

Access programming mode

 →     

Add/Delete

 →    

 Add -> Card ID

 → 

Input 5-digit user address

 → 

Input Site Code

 → 

Input Card Code

1

1

Adding Tag by Tag ID

Access programming mode

 →     

Add/Delete

 →    

 Delete -> Addr

 → 

Input Start address

 → 

Input End address

1

5

Deleteing User Address

Access programming mode

 →     

User Setting

 →    

 Access Mode

 → 

Input User Address 

→ 

0: Invalid; 1: Card ; 2: Card or PIN; 3: Card & PIN

2

2

Setting up the access mode

Access programming mode

 →     

Add/Delete

 →    

 Delete -> ID #

 → 

Input Site Code

 → 

Input Card Code

1

6

Deleteing Tag by Tag ID

Access programming mode

 →     

Add/Delete

 →    

 Suspend -> Addr

 → 

Input Start address

 → 

Input End address

1

3

Suspend User Address

Access programming mode

 →     

Add/Delete

 →    

 Suspend -> ID #

 → 

Input Site Code

 → 

Input Card Code

1

4

Suspend Tag by Tag ID

Access programming mode

 →     

Add/Delete

 →    

 Delete -> Addr

 → 

Input Start address

 → 

Input End address

1

7

Recover User Address

Access programming mode

 →     

Add/Delete

 →    

 Delete -> ID #

 → 

Input Site Code

 → 

Input Card Code

1

8

Recover Tag by Tag ID

Summary of Contents for Control Systems

Page 1: ...M 3 White COM DC24V1Amp Door Contact 4 Orange Negative Trigger Input Exit Switch 5 Purple Negative Trigger Input Alarm Relay 6 Gray DC24V1Amp Power 7 Thick Red DC 12V 8 Thick Black DC 0V Cable P1 Wire...

Page 2: ...tem will automatically exit from Programming Mode when inactivating for 30 seconds 2 LED status indicates controller s mode and status OK green blinking constantly when operates in Programming Mode or...

Page 3: ...ntial input Tag Units pcs in the quantity of the tags and present the tag with the lowest number to the controller 1 2 Adding Tag by RF Learn Function Tag Information SITE CODE CARD CODE SITE CODE CAR...

Page 4: ...open longer than door relay time plus door close time 2 Force open Opened without a valid user card Access by force or illegal procedure 3 Door position abnormal When power is off and then on reader o...

Page 5: ...ing Multi Floor Input 5 digit user address Select range 1 or 2 or 3 or 4 Input 16 digits multi floors number 0 disable 1 enable e g Set NO 114 can use it with the 8 F and 16F Access programming mode U...

Page 6: ...Tm 4 Door Close Tm 5 Alarm Relay Tm 6 Alarm Delay Tm 7 Arming Delay Tm 8 Arming PWD 2 User Setting 1 Password 2 Access Mode 3 Extend Options 4 Single Floor 5 Multi Floor 1 Add Delete 1 Add Card ID 2...

Page 7: ...device Please revise IP address you want and then click Update button After updating the IP please re connect the Web Browser by new IP address User Password The password composes of 10 characters at...

Page 8: ...R 401RO16 Programmer AR 737P AR 737H AR 727CM AR 701CM AR 321CM AR 821EVi V5 AR 821EF V5 AR 829E V5 AR 727H AR 727H AR 327H AR 721H AR 721K AR 721H AR 725K M AR 725U M AR 323D AR PB 321 AR PB 323 INTE...