Soyal Control Systems User Manual Download Page 1

SOYAL

ACCESS CONTROL SYSTEM

®

AR-829E-V5

V120508

    

AR-821RB

1

5

7

*

4

0

8

#

9

1

3

2

6

2

3

4

8

7

6

5

4

3

2

1

8 7 6 5 4 3 2 1

7

6

5

4

3

2

1

2

1

4

3

2

1

3 2 1

P2

6

5

4

3

2

1

P7

P3

P6

P5

P1

P4

P1

P2

P3

P4

P5

P6

Contents

2

User Guide

The communication wires and power line should NOT be bound in the same conduit or tubing.

Don’t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may make the 

reader malfunction.

The standard installation: Door relay and lock use the same power supply, and reader use independent power supply.

Use AWG 22-24 Shielded Twist Pair to avoid star wiring ,CAT 5 cable for TCP/IP connection

1.Tubing:

2.Wire selection:

3.Power supply:

Installation

Use a screwdriver to screw the mounting plate to the wall.
Pull cables ends through the access hole in the mounting plate. 
Attach AR-829E to the mounting plate and install screws (supplied) into the 
holes at the bottom with the allen key (supplied). 
Apply power. LED (green) will light up.

1

Products

3

Terminal Cables

4

Tools

5

Notice

Connector Table

Optional

AR-721RB

Digital Relay

Wire Application

Wire

Color

Description

Lock Relay

1

Blue White (N.O.)DC24V1Amp

2

Purple White (N.C.)DC24V1Amp

Lock Relay COM

3

White

(COM)DC24V1Amp

Door Contact

4

Orange

Negative Trigger Input

Exit Switch

5

Purple

Negative Trigger Input

Alarm Relay

6

Gray

DC24V1Amp

Power

7

Thick Red DC 12V

8

Thick Black DC 0V

Cable:

P1

Wire Application

Wire

Color

Description

Beeper

1

Pink

Beeper Output 5V/100mA, Low

LED

2

Yellow

Red LED Output 5V/20mA, Max

3

Brown

Green LED Output 5V/20mA, Max

Door Output

4

Blue White Transistor Output Max. 12V/100mA 

(Open Collector Active Low)

Wiegand

5

Thin Green Wiegand DAT: 0 Input

6

Thin Blue Wiegand DAT: 1 Input

WG Door Contact

7

Orange

Negative Trigger Input

WG  Exit Switch

8

Purple

Negative Trigger Input

P2

Wire Application

Wire

Color

Description

1

---

---

2

---

---

TCP/IP Output

3 Orange White

Net - TX+

4

Orange

Net - TX-

5

Green White Net - RX+

6

Green

Net - RX-

7

---

---

P3

Wire Application

Wire

Color

Description

RS-485 for Lift

Controller

1

Thick Green RS-485(B-)

2

Thick Blue RS-485(A+)

Cable:

P4

Wire Application

Wire

Color

Description

Anti-Tamper Switch

1

Red

N.C.

2

Orange

COM

3

Yellow

N.O.

P5

Wire Application

Wire

Color

Description

Power

1

Red

DC 12V Output

Security trigger signal 

2

Purple

Security trigger signal Output

Arming

3

Red White Arming Output

Duress

4

Yellow White Duress Output

P6

Wire Application

Wire

Color

Description

TTL Port 

1

Black

DC 0V

2

Yellow

TX

3

White

TE

4

Orange

RX

5

Red

DC 5V

6

---

---

Cable:

P7

Optional:(Request to purchase AR-725L485 additionally)       

Cable:

Cable:

Cable:

Cable:

Summary of Contents for Control Systems

Page 1: ...M 3 White COM DC24V1Amp Door Contact 4 Orange Negative Trigger Input Exit Switch 5 Purple Negative Trigger Input Alarm Relay 6 Gray DC24V1Amp Power 7 Thick Red DC 12V 8 Thick Black DC 0V Cable P1 Wire...

Page 2: ...tem will automatically exit from Programming Mode when inactivating for 30 seconds 2 LED status indicates controller s mode and status OK green blinking constantly when operates in Programming Mode or...

Page 3: ...ntial input Tag Units pcs in the quantity of the tags and present the tag with the lowest number to the controller 1 2 Adding Tag by RF Learn Function Tag Information SITE CODE CARD CODE SITE CODE CAR...

Page 4: ...open longer than door relay time plus door close time 2 Force open Opened without a valid user card Access by force or illegal procedure 3 Door position abnormal When power is off and then on reader o...

Page 5: ...ing Multi Floor Input 5 digit user address Select range 1 or 2 or 3 or 4 Input 16 digits multi floors number 0 disable 1 enable e g Set NO 114 can use it with the 8 F and 16F Access programming mode U...

Page 6: ...Tm 4 Door Close Tm 5 Alarm Relay Tm 6 Alarm Delay Tm 7 Arming Delay Tm 8 Arming PWD 2 User Setting 1 Password 2 Access Mode 3 Extend Options 4 Single Floor 5 Multi Floor 1 Add Delete 1 Add Card ID 2...

Page 7: ...device Please revise IP address you want and then click Update button After updating the IP please re connect the Web Browser by new IP address User Password The password composes of 10 characters at...

Page 8: ...R 401RO16 Programmer AR 737P AR 737H AR 727CM AR 701CM AR 321CM AR 821EVi V5 AR 821EF V5 AR 829E V5 AR 727H AR 727H AR 327H AR 721H AR 721K AR 721H AR 725K M AR 725U M AR 323D AR PB 321 AR PB 323 INTE...

Reviews: