background image

AR-837-EA

V210824

ACCESS & INDUSTRIAL CONTROL

   

H. Arming Password

J. Duress Code

K. Terminal Port

I. Arming Delay Time

Access programming mode

 →  

 

  

Parameters[1]

 →     

Arming PWD

 → 

Input 4-digit PIN (0001~9999; Default: 1234)

 → 

Succeeded

  

Or via 701Server and set it on  AR-829E  screen

3

8

Or via 701Server to set it on  AR-829E-V5  screen

Duress Code is only available in networking mode. It will substitute a personal pin code and send the message of Duress to computer as a    

    warning signal.

Access programming mode

 →  

 

  

Parameters[2]

 →     

Duress Code

 → 

4 sets (select one)

 → 

Input 4-digit PIN (0001~9999)

 → 

Succeeded

  

4

7

Access programming mode

 →  

 

  

Tools

 →     

Terminal Port

 → 

0:Lift ; 1:Host ; 2:LED ; 3:PRN (default value:1) 

→ 

Baud Selection 

(default value:9600)

 → 

Succeeded

  

5

4

L. Setting up the alarm / arming

Conditions:

1. Arming enabled
2.Alarm system connected

Situations:
1. Door is open overtime

: Door is open longer than door relay time plus door close time.

2. Force open

 (Opened without a valid user card): Access by force or illegal procedure.

3. Door position is abnormal

: Happening when power is off and then on again, besides, reader was on arming before power went off.

Access programming mode

 →     

Parameters[1]

 →     

ArmingDelayTm

 → 

Enter armed sta. Delay time(Sec), Range:000~255

Armed pulse out-put time (10ms) ,Range

000~255

 → 

Succeeded

  

3

7

F. Enroll/Delete Face 

Adding

Access programming mode

 →  

 

  

User Setting

 →    

 Delete Face

 → 

Key in 5-digit user address

 →

Follow the instruction on LCD Screen to enroll face 

Succeeded

2

6

Deleting

Access programming mode

 →  

 

  

User Setting

 →    

 Delete FP

 → 

Key in 5-digit user address

 → 

Succeeded

P.S. If want to delete all users’ face data’ FP, key in 

99999

2

7

#

G. Access Mode

Access programming mode

 →  

 

  

User Setting

 

→     

Access Mode

 

→ 

Key in 5-digit user address (00000~08999)

 

→ 

0: Invalid; 1:Card; 2: Card or PIN; 3: Card and PIN

 

(

837-EA

: → 

Face Identify: 0: Must ; 1: Ignore )

→ 

Succeeded

  

2

2

Access Mode

Face Identify (837-EA Only)

Result  (837-EA Only)

Hardware 701Client

Hardware

701Client

0:Invalid

0: Must

 

       Just Face

       Just card control

 

Invalid User

1: Ignore

       Just Face

       Just card control

1:Card

0: Must

       Just Face

       Just card control

 

Face+Card

1: Ignore

       Just Face

       Just card control

 1. Card Only

 2. Face Only

2:Card or PIN

0: Must

       Just Face

       Just card control

 1. Face+Card

 2. Face+PIN

 3. Card+Face+PIN

 4. Card+Face+Card

 5. PIN+Face+PIN

 6. PIN+Face+Card

1: Ignore

       Just Face

       Just card control

 1. Card Only

 2. PIN Only

 3. Face Only

3:Card and PIN

0: Must

       Just Face

       Just card control

 Face+Card+PIN

1: Ignore

       Just Face

       Just card control

 1. Card+PIN

 2. Face+PIN

E. PIN Code

Access programming mode

 →  

 

  

User Setting

 →     

Enroll Face

 → 

Input 5-digit user address

 → 

Input 4-digit PIN (0001~9999)

 → 

Succeeded

  

Or via 701Client set it on  Users  screen

2

1

Access programming mode

 →     

User Setting

 →    

 Access Mode

 → 

Input User Address 

→ 

0: Invalid; 1: Card ; 2: Card or PIN; 3: Card & PIN

2

2

Setting up the access mode

Access programming mode

 →     

Add/Delete

 →    

 Delete -> ID #

 → 

Input Site Code

 → 

Input Card Code

1

6

Deleting Tag by Tag ID

Summary of Contents for AR-837-EA

Page 1: ...C24V1Amp Door Contact 4 Orange Negative Trigger Input Exit Switch 5 Purple Negative Trigger Input Alarm Relay 6 Gray N O N C Optional by jumper Power 7 Thick Red DC 12V 8 Thick Black DC 0V Cable A 1 S...

Page 2: ...ut 5V 100mA Low LED 2 Yellow Red LED Output 5V 20mA Max 3 Brown Green LED Output 5V 20mA Max Door Output 4 Blue White Transistor Output Max 12V 100mA Open Collector Active Low Wiegand 5 Thin Green Wie...

Page 3: ...R 12VDC Electric Bolt CN4 CN8 3 4 5 6 7 8 2 1 4 1 2 3 837 EA WGoutput 12V GND CN4 CN4 CN8 CN5 CN5 BZ RLED GLED Door Output WG 0 WG 1 DS PB DS PB Duress ALM COM PB 12V GND 12V GND 1 2 3 4 5 6 7 8 1 2 3...

Page 4: ...ing constantly when operating in Programming Mode or flashing an existed card in card learn mode it comes 2 beeps warning and LCD panel displays Same Card user address card number Error red invalid ca...

Page 5: ...Delete Face Key in 5 digit user address Follow the instruction on LCD Screen to enroll face Succeeded 2 6 Deleting Access programming mode User Setting Delete FP Key in 5 digit user address Succeeded...

Page 6: ...Set Floor Stop 1 0 17 0 33 0 49 0 9 0 25 0 41 0 57 0 1 2 3 4 3 0 19 0 35 0 51 0 11 0 27 0 43 0 59 0 2 0 18 0 34 0 50 0 10 0 26 0 42 0 58 0 4 0 20 0 36 0 52 0 12 0 28 0 44 0 60 0 5 0 21 0 37 0 53 0 13...

Page 7: ...a IPV4 Succeeded IP Address Config 3 1 Parameter Setting Menu Set card display mode I nput New NodeID Range 001 254 Current Data 001 1 Add Delete 2 User Setting 3 Parameters 1 4 Parameters 2 1 Node ID...

Page 8: ...ata and analyze Controller extract data Data Comparison Verified successfully Face Enrollment Tips The face should be close to LCD screen The size of the face image is half of the LCD that will be mor...

Page 9: ...AR 837 EA V210824 ACCESS INDUSTRIAL CONTROL Notes and Tips for Registration and Recognition of Wearing Face Mask Detection Mode...

Reviews: