Soyal AR-837-E Manual Download Page 7

AR-837-E / EF

V200929

ACCESS & INDUSTRIAL CONTROL

   

   

RESET

   

Restoring Factory Settings

Firmware Upgrade

Reset all device parameters and user card data

Reset IP Setting:

When the device's power is on, press the

RESET

button on the main board untill the ERR (Red) 

LED of screen lights up. (Refere to the picture beside)

※ 

After operation as above, you will hear a long reminder sound,and wait until the sound disappears, 

and then reset the power of the controller. The device will be restored to factory settings.

Reset all device parameters and user card data:

Access programming mode

 →     

Parameters2 

→     

Factory Reset 

0 : System Param

 

1 : User Setting ; 2 : System & User

 

9

4

5

Get the upgrade software from SOYAL or our distributor and run “UdpUpdater” software

Update the firmware 

[Please login the SOYAL website to download the new ISP Firmware.]

1. Input the Target Address and Port
2. [Load F/W] open the documents that have the new ISP Firmware
3. Click the new ISP Firmware and [Open] it

4. Click [Update F/W] to start the firmware update

5. Till the screen shown [Firmware Update is Complete]

Execute the software

The software is within SOYAL CD or please login the SOYAL website to download

1

2

5

4

3

※ 

After having done the "Factory Reset," the External Communication Port must be reset. Or 

the biometric sensor won't be functional.

Tools →      Ext. Comm Port (0:FP-200

 ; 1:Lift ; 2:Vein2000 ; 3:FP-9000 ; 4:Reserved )

5

P. OpenZone

Q. Open TimeZone

Access programming mode

 →     

Parameters[1]

 →     

OnOff OpenZone

 → 

Main Controller Auto Open Zone

 

(0:disable, 1:enable) 

→ 

Open Door Imm. During Open Zone

 

(0:No, 1:Yes)

 → 

WG1 Port Auto Open Zone (0:disable, 1:enable) 

 

Open Door Imm. During 

Open Zone

 

(0:No, 1:Yes)

 → 

Succeeded

  

3

2

Access programming mode

 →     

Tools

 →     

Open TimeZone

 → 

Set (00~15) 

→ 

Time

 

(24

 

Hours)

 

;

 

Main Port (0:disable, 1: enable) ; 

WG Port (0:disable, 1: enable) 

→ 

Weekday

 

(0:disable, 1: enable)

 → 

succeeded 

 

5

6

Summary of Contents for AR-837-E

Page 1: ...Cable WireApplication Wire Color Description Door Bell 1 Black White Transistor Output Max 12V 100mA Open Collector Active Low 2 Black DC 0V Cable WireApplication Wire Color Description Beeper 1 Pink...

Page 2: ...lue Cable Cable Cable WireApplication Wire Color Description 1 2 TCP IP Output 3 Orange White Net TX 4 Orange Net TX 5 Green White Net RX 6 Gerrn Net RX 7 CN7 CN9 CN10 Connect to Electric Strike Conne...

Page 3: ...ess programming mode Tools Language EN Succeeded Initial system 5 1 0 N C N O COM 12V E BZ RLED GLED WG 0 WG 1 12V GND 12V GND Exit Switch 12V GND BZ RLED GLED Door Output WG 0 WG 1 WG DS WG PB EXI EX...

Page 4: ...perating in Programming Mode or flashing an existed card in card learn mode it comes 2 beeps warning and LCD panel displays Same Card user address card number Error red invalid card with 2 beeps warni...

Page 5: ...The AR 837EF 9000DO needs to collect twice for each fingerprint however AR 837EF 1500DO needs to collect three times for each fingerprint 2 6 Deleting Access programming mode User Setting Delete FP K...

Page 6: ...17 0 33 0 49 0 9 0 25 0 41 0 57 0 1 2 3 4 3 0 19 0 35 0 51 0 11 0 27 0 43 0 59 0 2 0 18 0 34 0 50 0 10 0 26 0 42 0 58 0 4 0 20 0 36 0 52 0 12 0 28 0 44 0 60 0 5 0 21 0 37 0 53 0 13 0 29 0 45 0 61 0 6...

Page 7: ...ISP Firmware 1 Input the Target Address and Port 2 Load F W open the documents that have the new ISP Firmware 3 Click the new ISP Firmware and Open it 4 Click Update F W to start the firmware update...

Page 8: ...Ethernet Module device Please alter the IP address as you want and then click Update button After updating the IP please re connect the Web Browser by the new IP address User Password The password is...