![Soyal AR-837-E Manual Download Page 1](http://html1.mh-extra.com/html/soyal/ar-837-e/ar-837-e_manual_1338280001.webp)
AR-837-E / EF
V200929
ACCESS & INDUSTRIAL CONTROL
B.
或
1
2
CN7
CN8
CN3
CN13
CN6
CN5
CN4
AR-837i
AR-MDL-721V
AR-WG-HID
AR-837i
AR-MDL-721V
AR-WG-HID
8
8
2
1
3 2 1
CN4
CN4
CN6
CN6
CN3
CN3
CN8
CN8
CN13
CN13
CN5
CN5
9DO
837-E
3DO
837-EE
Contents
2
Terminal Cables
The communication wires and power line should NOT be bound in the same conduit or tubing.
Don’t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may cause a
malfunction in the reader.
The standard installation: Door relay and lock use the same power supply, and reader should use another independent power supply.
Use AWG 22-24 Shielded Twist Pair to avoid star wiring, CAT 5 cable for TCP/IP connection
1.Tubing:
2.Wire selection:
3.Power supply:
1
Products
3
Tools
4
Optional
Notice
Connector Table (1)
(HID RF Module)
(HID RF Module)
(TCP/IP Module)
(TCP/IP Module)
(Voice Module)
(Voice Module)
Wire Application
Wire
Color
Description
Lock Relay
1
Blue White (N.O.)DC24V1Amp
2
Purple White (N.C.)DC24V1Amp
Lock Relay COM
3
White
(COM)DC24V1Amp
Door Contact
4
Orange
Negative Trigger Input
Exit Switch
5
Purple
Negative Trigger Input
Alarm Relay
6
Gray
N.O./N.C. Optional (by jumper)
Power
7
Thick Red DC 12V
8
Thick Black DC 0V
Cable:
Wire Application
Wire
Color
Description
RS-485 for Lift
Controller
1
Thick Green RS-485(B-)
2
Thick Blue RS-485(A+)
Cable:
Wire Application
Wire
Color
Description
Door Bell
1
Black White Transistor Output Max. 12V/100mA
(Open Collector Active Low)
2
Black
DC 0V
Cable:
Wire Application
Wire
Color
Description
Beeper
1
Pink
Beeper Output 5V/100mA, Low
LED
2
Yellow
Red LED Output 5V/20mA, Max
3
Brown
Green LED Output 5V/20mA, Max
Door Output
4
Blue White Transistor Output Max. 12V/100mA
(Open Collector Active Low)
Wiegand
5
Thin Green Wiegand DAT: 0 Input
6
Thin Blue Wiegand DAT: 1 Input
WG Door Contact
7
Orange
Negative Trigger Input
WG Exit Switch
8
Purple
Negative Trigger Input
Cable:
2
Terminal Cables
1
Products
3
Tools
4
Optional
A-1.Surface Mounted: Use a screwdriver to screw the mounting plate
to the wall. A-2.Embedded: To dig a hole for 837-E:85mmx113mm /
837-EF:128mmx109mm; and then, use a screwdriver to screw the
mounting plate to the wall.
Pull cable ends through the access hole in the mounting plate.
Attach AR-837-E or AR-837-EF to the mounting plate and install
screws (supplied) into the holes at the bottom with the allen key.
Apply power. LED (green) will light up with one beep.
Installation
AR-837-EF:Fingerprint
AR-837-E/ EE
Wire Application
Wire
Color
Description
Reserved
1
Red
--
Security trigger signal
2
Purple
Security trigger signal Output
Arming
3
Red White Arming Output
Duress
4
Yellow White Duress Output
Cable:
Wire Application
Wire
Color
Description
Anti-Tamper Switch
1
Red
N.C.
2
Orange
COM
3
Yellow
N.O.
Cable:
Water proof Strip
Water proof Strip
Screws
Screws
Or
A-1.Surface
Mounted
A-2.Embedded
CN4
CN3
CN8
CN13
CN6
CN5
AR-837-E
AR-837-EE
Screws