Soyal AR-837 E User Manual Download Page 7

SOYAL

ACCESS CONTROL SYSTEM

®

AR-837 (E) / (EF)

V140217

   

   

   

RESET

Restoring Factory Settings

Firmware Upgrade

Reset all device parameters and user card data

Reset IP Setting:

When the device's power is on, press the

RESET

button on the main board untill the ERR (Red) 

LED of screen lights up. (Refere to the picture beside)

※ 

After operation as above, you will hear a long reminder sound,and wait until the sound disappears, 

and then reset the power of the controller. The device will be restored to factory settings.

Manu Tree

5. Tools

1. Language
2. Master Code
3. Master Range
4. Terminal Port
5. Ext.Comm Port
6. Open Time Zone
7. Informations
8. Clock Setting
9. Daily Alarm

6. Quit

7. Quit & Arming

4. Parameters[2]

1. Auto Relock
2. Egress(R.T.E)
3. Miscellaneous
4. Force Open
5. Close & Stop
6. Anti-pass-back
7. Duress Code
8. Password Mode
9. Factory Reset

3. Parameters[1]

1. Node ID
2. OnOff OpenZone
3. Door Relay Tm
4. Door Close Tm
5. Alarm Relay Tm
6. Alarm Delay Tm
7. Arming Delay Tm
8. Arming PWD

2. User Setting

1. Password
2. Access Mode
3. Extend Options
4. Single Floor
5. Multi Floor
6. Enroll Finger
7. Delete Finger

1. Add/ Delete

1. Add > Card ID
2. Add > RF Learn
3. Suspend > Address
4. Suspend > ID #
5. Delete > Address
6. Delete > ID #
7. Recover > Address
8. Recover > ID #
9. Antipass Group

Reset all device parameters and user card data:

Access programming mode

 →     

Parameters2 

→     

Factory Reset 

0 : System Param

 

1 : User Setting ; 2 : System & User

 

9

4

5

Get the upgrade software from SOYAL or our distributor and run “UdpUpdater” software

Update the firmware 
[Please login the SOYAL website to download the new ISP 

1. Input the Target Address and Port
2. [Load F/W] open the documents that have the new ISP Firmware
3. Click the new ISP Firmware and [Open] it

4. Click [Update F/W] to start the firmware update

5. Till the screen shown [Firmware Update is Complete]

Execute the software

The software is within SOYAL CD or please login the SOYAL website to download

1

2

5

4

3

※ 

After having done the "Factory Reset," the External Communication Port must be reset. Or 

the biometric sensor won't be functional.

Tools →      Ext. Comm Port (0:FP-200

 ; 1:Lift ; 2:Vein2000 ; 3:FP-9000 ; 4:Reserved )

5

837E-EF-140217.indd   7

2014/12/17   下午 04:05:24

Summary of Contents for AR-837 E

Page 1: ...ck Blue RS 485 A Cable CN6 P4 WireApplication Wire Color Description Door Bell 1 Black White Transistor Output Max 12V 100mA Open Collector Active Low 2 Black DC 0V Cable 7 CN13 P7 WireApplication Wir...

Page 2: ...ed Arming Green OK Green Error Red In processing Green Networking and interactively flash between the Month and DAY e g 12 07 12 07 Stand alone No flashing e g 12 07 Reference to picture Connect to El...

Page 3: ...2VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC Electric Strike Door Contact Strengthen security with AR 721RB Electric Bolt Electric Bolt Electric Bolt Fire Emergency Tra...

Page 4: ...digit user address Input Tag Units pcs Close Tag into RF Area If the batch of tags are Sequential input Tag Units pcs in the quantity of the tags and present the tag with the lowest number to the con...

Page 5: ...t Arming 7 Disable Access programming mode Quit 6 No open the door Input 4 digit arming PWD Present the tag to reader Access programming mode Parameters 1 ArmingDelayTm Enter armed sta Delay time Sec...

Page 6: ...etting Multi Floor Input 5 digit user address Select range 1 or 2 or 3 or 4 Input 16 digits multi floors number 0 disable 1 enable e g Set NO 114 can use it through the 8 F and 16F Access programming...

Page 7: ...User Setting 1 Password 2 Access Mode 3 Extend Options 4 Single Floor 5 Multi Floor 6 Enroll Finger 7 Delete Finger 1 Add Delete 1 Add Card ID 2 Add RF Learn 3 Suspend Address 4 Suspend ID 5 Delete Ad...

Page 8: ...ticker on Ethernet Module device Please alter the IP address as you want and then click Update button After updating the IP please re connect the Web Browser by the new IP address User Password The pa...