Soyal AR-721E User Manual Download Page 3

SOYAL

ACCESS CONTROL SYSTEM

®

AR-721E

V100630

   

   

Enable/Disable auto open zone

Access programming mode

 → 

20     004       [004= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]

Enable/Disable auto open door without presenting card

Access programming mode

 → 

24     001       [001= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]

[e.g.] To set the second time zone as 9:30 AM to 4:20 PM, Monday, Wednesday and Friday: 08     1     09301612     01010100     

 → 

Done

N: 2 sets of auto-open zone (N=0=1st set; N=1=2nd set)
HHMMhhmm=Staring time to ending time (e.g. 08301200=08:30 to 12:00)
6543217H= 7 days of week (Sat/Fri/Thu/Wed/Tue/Mon/Sun) + Holiday (F= 0: disable; 1: enable); Holidays establish by the software.

Set up open time

Access programming mode

 → 

08     N     HHMMhhmm     6543217H

[e.g.] No. 154 enable the anti-pass-back, and induction into the door has not been induced to leave. When he re-induction into the door will become 
         invalid , then he needs to set the reset.  Access programming mode

 → 

26     00154     00154     2     

 → 

Reset

[e.g.] User address from 00152 to 00684 enable the anti-pass-back function:

 

26     00152     00684     0

Card enable

Access programming mode

 → 

26     SSSSS     EEEEE     N      

[SSSSS= User address start; EEEEE= User address end; N=0(control)/ 1(Not control)/ 2(reset)]

Controller enable

Access programming mode

 → 

20     DDD       [128= Anti-pass-back(0=Disable; 1=Enable)/ 064=Access/Exit(0=Exit; 1=Access).]

         Access programming mode

 → 

20     128      (Please refer to function default value for details.)

[e.g.] Enable Anti-pass-back, and set to Exit door= (128 x 1) + (064 x 0) = 128

Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or to situations need 

access and exit monitor.

Card or PIN:

 

Access programming mode

 → 

12     UUUUU     PPPP       [e.g. User address: 00001 and pass code: 1234, input 12     00001     1234     ]

Card and PIN:

 

Access programming mode

 → 

13     UUUUU     PPPP       [e.g. User address: 00001 and pass code: 1234, input 13     00001     1234     ]

Access programming mode

 → 

00     NNN        [Node ID: 001~255]

Door will keep open after the first flashing card.There are 2 time zones supported.

Access programming mode

 → 

04     N       [N=4/8]

D. Set up the password

E. Anti-pass-back(Reader A and Reader B must to be setting)

F. Auto Open Time Zone

B. Chang the Node ID of Reader

C.Set up M4/M8

G. Setting Up the Arming

Alarm conditions:

1. Arming is enabled
2.Alarm system connected

Enable: 

Access programming mode

 → 

Disable: 

Access programming mode

 → 

Enable/Disable Arming status (Factory default armingcode is: 1234) :

Standby Mode

Enter Program Mode

After door open

The normal procedure to open door

 → 

Input 4 digit arming code

 →

Door is not open

     → 

Input 4 digit arming code

 → 

Present valid card

※ 

[The normal procedure to open door] can refer to [Access Mode].

Application:
1. Door open too long

: Door is open longer than door relay time plus door close time.

2. Force open

 (Opened without a valid user card): Access by force or illegal procedure.

3. Door position abnormal

: When power is off and then on, reader on arming bffore power off.

Function Default Value

20    DDD

Function

Selection

Value

Bit

Application

Default Value

Attendance
Auto Re-lock
Auto Open
Door open button input
Master Reader of Network

Access/Exit 

Anti-pass-back 

0: Yes

0: Disable

0: Disable

   

0: Disable

0: Slave

0: Exit

0: Disable

Networking
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking
Networking
Networking

001
002
004
016
032
064
128

   1: No
   1: Enable
   1: Enable

1: Enable

   1: Mater
   1: Access
   1: Enable

0
1
2
4
5
6
7

Bit

Function

Selection

Value

Application

Auto-open door without cards at auto open zone
Stop Alarm by door close or by push button

0: Disable

0: None

Networking/Stand-Alone
Networking/Stand-Alone

1: Enable
1: Yes

24    DDD

Default Value

001
064

0
6

Reviews: