SOYAL
ACCESS CONTROL SYSTEM
®
AR-721E
V100630
Enable/Disable auto open zone
Access programming mode
→
20 004 [004= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]
Enable/Disable auto open door without presenting card
Access programming mode
→
24 001 [001= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]
[e.g.] To set the second time zone as 9:30 AM to 4:20 PM, Monday, Wednesday and Friday: 08 1 09301612 01010100
→
Done
N: 2 sets of auto-open zone (N=0=1st set; N=1=2nd set)
HHMMhhmm=Staring time to ending time (e.g. 08301200=08:30 to 12:00)
6543217H= 7 days of week (Sat/Fri/Thu/Wed/Tue/Mon/Sun) + Holiday (F= 0: disable; 1: enable); Holidays establish by the software.
Set up open time
Access programming mode
→
08 N HHMMhhmm 6543217H
[e.g.] No. 154 enable the anti-pass-back, and induction into the door has not been induced to leave. When he re-induction into the door will become
invalid , then he needs to set the reset. Access programming mode
→
26 00154 00154 2
→
Reset
[e.g.] User address from 00152 to 00684 enable the anti-pass-back function:
26 00152 00684 0
Card enable
Access programming mode
→
26 SSSSS EEEEE N
[SSSSS= User address start; EEEEE= User address end; N=0(control)/ 1(Not control)/ 2(reset)]
Controller enable
Access programming mode
→
20 DDD [128= Anti-pass-back(0=Disable; 1=Enable)/ 064=Access/Exit(0=Exit; 1=Access).]
Access programming mode
→
20 128 (Please refer to function default value for details.)
[e.g.] Enable Anti-pass-back, and set to Exit door= (128 x 1) + (064 x 0) = 128
Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or to situations need
access and exit monitor.
Card or PIN:
Access programming mode
→
12 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 12 00001 1234 ]
Card and PIN:
Access programming mode
→
13 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 13 00001 1234 ]
Access programming mode
→
00 NNN [Node ID: 001~255]
Door will keep open after the first flashing card.There are 2 time zones supported.
Access programming mode
→
04 N [N=4/8]
D. Set up the password
E. Anti-pass-back(Reader A and Reader B must to be setting)
F. Auto Open Time Zone
B. Chang the Node ID of Reader
C.Set up M4/M8
G. Setting Up the Arming
Alarm conditions:
1. Arming is enabled
2.Alarm system connected
Enable:
Access programming mode
→
Disable:
Access programming mode
→
Enable/Disable Arming status (Factory default armingcode is: 1234) :
Standby Mode
Enter Program Mode
After door open
The normal procedure to open door
→
Input 4 digit arming code
→
Door is not open
→
Input 4 digit arming code
→
Present valid card
※
[The normal procedure to open door] can refer to [Access Mode].
Application:
1. Door open too long
: Door is open longer than door relay time plus door close time.
2. Force open
(Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal
: When power is off and then on, reader on arming bffore power off.
Function Default Value
20 DDD
Function
Selection
Value
Bit
Application
※
Default Value
Attendance
Auto Re-lock
Auto Open
Door open button input
Master Reader of Network
Access/Exit
Anti-pass-back
※
0: Yes
※
0: Disable
※
0: Disable
0: Disable
※
0: Slave
※
0: Exit
※
0: Disable
Networking
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking
Networking
Networking
001
002
004
016
032
064
128
1: No
1: Enable
1: Enable
※
1: Enable
1: Mater
1: Access
1: Enable
0
1
2
4
5
6
7
Bit
Function
Selection
Value
Application
Auto-open door without cards at auto open zone
Stop Alarm by door close or by push button
※
0: Disable
※
0: None
Networking/Stand-Alone
Networking/Stand-Alone
1: Enable
1: Yes
24 DDD
※
Default Value
001
064
0
6