10
Setting Value
Notes
Necessity
Local IP Address
192.168.001.127 Defines own IP Address of the
AR-727CM
Required
Local Gateway IP
Address
192.168.001.254 Defines the IP Address of the default
gateway
Required
Local Subnet Mask 255.255.255.000 Defines the IP Address range for the
local network segment
Required
TCP Port
1621
The TCP port that other devices must
use to contact this device. To avoid
conflicts with standard TCP ports.
Required
MAC Address
00.E0.4C.00.00.50 The MAC (Media Access Control)
address is a unique identifier set at the
factory.
-
Force Transmit time
5
Forces AR-727CM device’s TCP/IP
protocol software to try to pack serial
data received during the specified time
into the same data frame.
Optional
Force Transmit Bytes 32
Defines the amount of data in the
serial, Ethernet buffer at which the
break condition will be generated and
the contents of buffer will be sent out
via the Ethernet port.
Optional
Lock Remote IP
Address
-
Allows contact with only the specified
remote IP address.
Optional
Lock Serial Port
(Free Run or Freeze
Over)
-
To avoid the hacker use this IP to
intercept data when Remote IP
Address doesn’t receive data.
Optional
Setup Password
none
Console password
Optional
Serial Port Speed
9600
Changes current baud rate of the
AR-727CM’s serial port (from 2400bps
to 57600bps).
Required
TCP Auto Disconnect
Time
(Second)
60
This device automatically closes TCP
connection if there is no TCP activity
for the given time.
Optional
Serial Port Hardware
Handshaking
(RTS/CTS)
-
An exchange of signal over specific
wires which each device indicates its
readiness to send or receive data.
Optional
DHCP - Selecting
the
enable option allows
DHCP to automatically assign the
AR-727CM’s IP address.
Optional