V220922
AR-331-E/EF
SOYAL
ACCESS CONTROL SYSTEM
- 10 -
Command List (By WG Keyboard)
Function
Command
Exposition
Real time clock setting
25 YYMMDDHHMMSS
YYMMDDHHMMSS
=
Year/Month/Day/Hour/Min./Sec.
Anti-pass-back (Enable user)
26 SSSSS EEEEE P
SSSSS= starting user address; EEEEE= ending user address
P=0=Enable; P=1=Disable; P=2=Initial
Lift control setting: single door
27 UUUUU LL
UUUUU
=
user address
;
LL
:
Floor number(01~64 floor)
Duress Function and Arming output setting
28 ???
Arming output and Duress function: ???= 008 (default value)
Delete all tag/Delete all tag + parameters setting
29 29 / 29 299
Same tag reading interval time
31 TTTT
Base on 10ms, range from 10 to 6000
Auto ring the clock alarm schedule
32 SS HHMMTT 7123456H
SS= 16 sets auto alarm schedule, range 0~15
HHMM= HH:MM (ex. 0830: Ring bell at 08:30)
TT=Period of time to ring bell
(Base on second, range 01~99 sec.)
7123456: 7 days of week -Sun/Mon/Tue/Wed/Thu/Fri/Sat
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)
Holiday Setting
35 MMDD F
MM= Month of year (01=Jan...10=Oct.)
DD= Date of month (01=1st day of month)
F= 0:Delete ; 1: Add
Enabling or Disabling into Full Access status
36 MW
M=AR-331-EF ; W=WG Reader (0=disable; 1=enable)
RS485 port function setting
(Needs to be restarted after setting)
37 AB
A
=
0:AR401RO B
=
0: 9600(default value)
1:Host (default value) 1: 19200
2:LED Panel 2: 38400
3:Printer 3: 57600
Adding / Deleting Fingerprint
39 F UUUUU
F
=
1
: Adding one finger data /
2:
Adding two finger data
3:Adding three finger data /
0: Delete
UUUUU
=
user address
Deleting All Fingerprint
39 9 99999
En/Disable Skip Finger/Tag
40 F NNNNN EEEEE
First 40*1*
NNNNN*EEEEE#
Then 40*3*
NNNNN*EEEEE#
Change WG bits output format
41 n
n
:
0
=
WG26
;
n
:
1
=
WG34
PIN & UID
Length setting
42 m n
m
=
PIN code Length
4~8 Digit
n
=
UID Length
4~8 Digit
n
=
UID Length
2~8 Digit
Compound Command Function List
Access mode: FP first and then Tag (Default Value)
setting a pair of command
setting a pair of command
Access mode: FP only or Tag only
First 40*0*
NNNNN*EEEEE#
Then 40*2*
NNNNN*EEEEE#
NNNNN= starting user address;EEEEE= ending user address
20 0 ??? (Main Controller Parameter Setting)
20 1 ??? (WG Input Port Parameter Setting)
※
Default Value
Function
Option
Value
Bit
Application
Entry and Exit Access is recorded on Duty Report
※
0: Yes
1: No
001
0
Networking
Activate close door automatically lock (Auto-Relock)
※
0: Disable 1: Enable
002
1
Networking/Stand-Alone
Auto Open
※
0: Disable 1: Enable
004
2
Networking/Stand-Alone
When Access Mode is "Card and PIN", Readers can skip pressing PIN code
※
0: Disable 1: Enable
008
3
Networking/Stand-Alone
Exit by Push Button
0: Disable
※
1: Enable
016
4
Networking/Stand-Alone
Enable force Open trigger alarm
※
0: Disable 1: Enable
032
5
Networking
Entry/Exit Reader
※
0: Exit
1: Entry
064
6
Networking
Anti-pass-back
※
0: Disable 1: Enable
128
7
Networking
Weighted Value Manual :
"Selection"
of the function that you need is either
have 0 or 1 value.
Substract the
"Value"
of each Option with Selection.
Function = [0(deactive)*Value] ; [1(activate)*Value]
Add up all of the Function per Compound Command
(20 , 24 ,etc)
Step 1:
Select the
"Function"
that you need for each
Compound Command category (20 , 24 , etc)
Step 2:
Step 3:
Step 4: