Soyal AR-327H Manual Download Page 4

V091021

   

   

LCD Access Controller 

Metal Case / Standard

Access programming mode

 →     

Add/Delete

 →    

 Antipass Group

 → 

Input Start address

 → 

Input End address

 → 

1: Yes; 2: No;(select one)

1

9

Card set-up

Usually, anti-pass-back is commonly applied to parking lots in order to prevent from multi-entry with one card, requires to set bith card and 

device as the flowings:

E. Anti-pass-back(M4/M8 only)

Device set-up

Access programming mode

 →     

Parameters[2]

 →    

 Anti-pass-back

 → 

1: Yes; 2: No;(select one)

 → 

1: In; 2: Out;(select one)

4

7

F. Lift control

Connect with 

AR-401RO16B

 to control which floors the user will be able to access.

Set Floor

1

0

17

0

9

0

25

0

1

2

3

0

19

0

11

0

27

0

2

0

18

0

10

0

26

0

4

0

20

0

12

0

28

0

5

0

21

0

13

0

29

0

6

0

22

0

14

0

30

0

7

0

23

0

15

0

31

0

8

1

24

0

16

1

32

0

Access programming mode

 →     

Tools

 →    

 Termingal Port

 → 

1

AR-401RO16

5

4

Setting Lift control

Access programming mode

 →     

User Setting

 →    

 Single Floor

 → 

Input 5-digit user address

 → 

Input single floor number: 1~32

2

4

Single floor set-up

Access programming mode

 →     

User Setting

 →    

 Single Floor

 → 

Input 5-digit user address

 → 

Select range: 1 or 2

 → 

Input 16 digits multi 

floors number [0:disable, 1: enable]

[e.g.] Set NO. 114, to access the 8th and the 16th floors.

       

Access programming mode

 →     

User Setting

 →    

 Single Floor

 → 

114

     

 

→ 

1     

 

→ 

0000000100000001

           

2

2

5

5

Multi floors set-up

G.Setting Up the Arming

Conditions:

1. Arming is enabled
2.Alarm system connected

Application:
1. Door open over time

: Door is open longer than door relay time plus door close time.

2. Force open

 (Opened without a valid user card): Access by force or illegal procedure.

3. Door position abnormal

: When power is off and turn back on, reader on arming bffore power off.

Enable:

 Access programming mode

 →     

Quit & Arming

7

Disable:

 Access programming mode

 →     

Quit

6

Enable/Disable Arming status:

Standby Mode

Enter Program Mode

Card only

Card or Passcode

Card and Passcode

After door open

Induct valid card

 → 

Input 4 digit 

arming code

 →

Input 5 digit user address

 → 

Input 4 digit pass code

 →      → 

Input 4 digits arming code

 →

Induct valid card

 → 

Input 4 digit 

pass code

 →      → 

Input 4 digits 

arming code

 →

Door is not open

     → 

Input 4 digit arming code

 

→ 

Induct valid card

Manu Tree

5. Tools

1. Language

2. Master Code

3. Master Range

4. Terminal Port

5. AR401RO16 Node

6. Open Time Zone

7. Information

8. Clock Setting

9. Control Mode

0. View Events

6. Quit

7. Quit & Arming

4. Parameters[2]

1. Auto Relock

2. Egress(R.T.E)

3. Attendance

4. Master Node

5. Force Open

6. Close & Stop

7. Anti-pass-back

8. Duress Code

9. Factory Reset

0. Key (#) is Bell 

3. Parameters[1]

1. Node ID

2. Auto open Zone

3. Door Relay Tm

4. Door Close Tm

5. Alarm Relay Tm

6. Alarm Delay Tm

7. Arming Delay Tm

8. Arming PWD

9. Arming Pulse

0. Auto Alarm Tm

2. User Settings

1. Password

2. Access Mode

3.Extend Options

4. Single Floor

5.Multi Floor

1. Add/ Delete

1. Add Card >ID

2. Add > RF Learn

3. Suspend > Address

4. Suspend > ID #

5. Delete > Address

6. Delete > ID #

7. Recover > Address

8. Recover > ID #

9. Antipass Group

Access programming mode

 →     

Tools

 →    

 Control Mode

 → 

1:M4, 2:M6, 3:M8

(refer to below chart) 

→ 

Succeeded

5

9

D.Setting up the control mode (M4/M6/M8)

※ 

The users up to 65,535 in 

Mode 6

, since it reads 

CARD CODE

(5 digits) only, unlike that Mode4/Mode8 read 

SITE CODE

 and 

CARD CODE

(10 digits).

Mode

Networking/
Stand-Alone

Stand-Alone

Networking/
Stand-Alone

Networking/

Stand-Alone

User 

Capacity

Access Mode

M4

M6

M8

Yes

No

Yes

Yes

No

Yes

Yes

No

Yes

Yes

No

Yes

32

No

32

11

No

11

1,200

No

1,200

1,024

(0~1,023)

65,535

(1~65,535)

1,024

(0~1,023)

Auto-show 

Duty time

Event log 

Capacity

120 

Holidays

Anti 

force

Time 

Zone

Lift 

Control

Anti-pass-

back

1.Card only

2.Card and PIN 

(4-digit PIN)

3.Card or User address 

(5-digit)

 + Individual PIN 

(4-digit individual PIN)

1.Card only

2.Card and PIN 

(4-digit public PIN= Arming PWD)

3.Card or PIN 

(4-digit public PIN= Duress code)

1.Card only

2.Card and PIN 

(4-digit individual PIN)

3.Card or PIN 

(4-digit individual PIN)