background image

AR-323-D

V200623

ACCESS & INDUSTRIAL CONTROL

- 8 -

Smart Digital Door Lock

RF Card

Mode

M4/M6/M8

Function

Enable the security trigger signal ( with AR-721RB)

Description

Change the "Arming" (in      ) to the security trigger signal, 
when controller is connected with AR-721RB.

Please refer to function default value for details.

Command

34      DDD 

P5

   

34    DDD

Function

Selection

Value Application

Default Value

Enable the RF after door sensor closed to GND
Invalid card to activate alarm relay

Turn off all sounds of beeper

Mute the sounds of egress button (RTE) 
Reserved
Keep beeing while arming is enabled
Door relay connected to AR-721RB (suited to models without relay built-in)
Arm relay connected to AR-721RB (suited to models with relay built-in)

0: Deactivate

0: Deactivate

0: Deactivate

0: Deactivate

0: Deactivate

0: Deactivate

0: Deactivate

0: Deactivate

Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone

001
002
003
004
016
032
064
128

1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate

   

2

1

323DMaster

Test

 

MASTER CARD Setting

Use the MASTER CARD software

Input the MASTER CARD number, and press [Write].

Cut off and tranmit the power. Activate master

the card number.

Present the card, and the reader will flash green 

light 3 times and sound 3 beeps. Then the 

card becomes MASTER CARD and accesses 

programming mode.If MASTER CARD is presented 

again, it will exit programming mode.

About Master Card / Master Card

Adding Tag

Deleting All Tags

Present Master Card

Present Master Card

P.S. Once MASTER CARD is presented after one 

        warning beep, all card data will be cleared.

After 3 short beeps

[Access programming mode]

After 3  short beeps

[Access programming mode]

Present one new card at a time

1 long warning beep after 2sec.

Present Master Card

[Exit programming mode]

5 short beeps after 5sec: cards cleared

1.

1.

2.

2.

3.

3.

4.

4.

Summary of Contents for AR-323D

Page 1: ...ower DC0V Power DC12V Wire Application Door Handle Direction RH Right Push LH Left Push RHR Right Pull Before installation please check which door hand you require LHR Left Pull Door Handle Mortise Lock Sticker Strike Sticker 1 Mortise 2 Mortise Plate mounted 3 Spindle of Knob 4 Spindle of Handle x2 11 Screw x2 5 Cylinder Lock 6 Mechanical Key x2 7 Waterproof Strap x2 8 Handle Screw x2 9 Elastic S...

Page 2: ... make cuts depending on hole stickers dimension Remove 2 Mortise Plate from 1 Mortise lock body Note 1 Only make deadbolt knob hole from inner door to mortise don t cross to outer door 2 Make sure accurate position right hole direction of striker plate before making cuts latch bolt position can be made firstly 3 Networking mode Additional hinge cuts is required for PC connection Separate 2 Mortise...

Page 3: ...dy and wired on site 4 5 6 Important 1 The depth of the 5 Cylinder Lock installation has already fixed The screw position must meet with the hollow part of the 5 Cylinder Lock 2 We suggest making sure that the upper bolt and the lower bolt functions correctly before fixing the screw Testing can be made using the mechanical key by rotating it to left and right and it will move bolt position means i...

Page 4: ...tion and the flat surface is facing out Provided 7 Waterproof Strap is recommended to apply for waterproof function and to preserve the lock durability from door opening and closing Front panel Connect 1 Mortise to Front Panel 10 STEP 1 Connect the Front Panel CN3 Connector of Mortise to 1 Mortise STEP 2 Bring CN2 Connector of Reader into Cable Hole to be connected to Back Panel later STEP 3 Plug ...

Page 5: ...l cover STEP 1 STEP 2 Back panel CN1 X CN2 Y 1 Connect 1 Mortise to Back Panel 13 STEP 1 Connect the CN1 Power and Communication Cable to DC power and RS485 communication refer to the Wiring Section STEP 2 Continuation from Step 10 2 connect the cable from Cable Hole to CN2 Connector of Reader of the Back Panel STEP 3 Fasten 3 Spindle of Knob from Deadbolt Knob Hole of 1 Mortise into Deadbolt Knob...

Page 6: ... Front Panel Back Panel and Front Panel position is in correct position 1 Peel off Strike Sticker and paste into the desired spot for installation 2 Start making the hole drilling based on the hole dimension on the sticker 3 Remove the sticker after hole drilling is finished STEP 1 Embed the Strike Box into the hole STEP 2 Embed the Strike Plate on Strike Box and fasten with Screws STEP 3 Installa...

Page 7: ...ant to modify refer to password setting 17 Add Tags Input 123456 or Master Code 11 SSSSS EEEEE OK e g Add User Address 00100 01254 Enter program mode 11 00100 01254 OK Add tag by presenting Delete tag by presenting Input 123456 or Master Code 22 1 Present the tag to Access Controller OK Input 123456 or Master Code 22 0 Present the tag to Access Controller OK Delete All Tags Input 123456 or Master ...

Page 8: ...y and Friday 08 1 09301620 01010100 Done M4 M8 Private PIN Card or PIN Enter program mode 12 UUUUU PPPP e g User Address 00001 and pass code 1234 input 12 00001 1234 Card and PIN Enter program mode 13 UUUUU PPPP e g User Address 00001 and pass code 1234 input 13 00001 1234 M6 Public PIN Card or PIN Enter program mode 15 PPPP Input 4 digit PIN default value 4321 PPPP 0000 cancel the function of sim...

Page 9: ...suddenly off then on Function Default Value M4 M6 M8 24 DDD Function Selection Value Application Default Value Auto Open without Presenting in Auto open Time Zone Alarm Output Lift Control Stop Alarm by pressing RTE Button or Closing the Door Doorbell 0 Disable 0 Alarm Output 0 None 0 Disable Networking Standalone Networking Standalone Networking Standalone Networking Standalone 001 002 064 128 1 ...

Page 10: ...e buffer time before entering arming mode 001 600 1 600 sec TTT the buffer time before the alarm is activated 001 600 1 600 sec SSSSS EEEEE 00000 01023 00000 03000 for AR 725H SSSSS Starting User Address EEEEE Ending User Address N 0 1st time zone 1 2nd time zone HHMM Starting time hhmm ending time i e 08301600 08 30 to 16 00 7123456H 7 days of week Sun Mon Tue Wed Thu Fri Sat Holiday H 0 disable ...

Page 11: ...Networking Standalone Networking Standalone Networking Standalone Networking Standalone Networking Standalone Networking Standalone 001 002 003 004 016 032 064 128 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 2 1 323DMaster Test MASTER CARD Setting Use the MASTER CARD software Input the MASTER CARD number and press Write Cut off and tranmit the power Acti...

Reviews: