AR-323-D
V200623
ACCESS & INDUSTRIAL CONTROL
- 8 -
Smart Digital Door Lock
RF Card
Mode
M4/M6/M8
Function
Enable the security trigger signal ( with AR-721RB)
Description
Change the "Arming" (in ) to the security trigger signal,
when controller is connected with AR-721RB.
Please refer to function default value for details.
Command
34 DDD
P5
34 DDD
Function
Selection
Value Application
※
Default Value
Enable the RF after door sensor closed to GND
Invalid card to activate alarm relay
Turn off all sounds of beeper
Mute the sounds of egress button (RTE)
Reserved
Keep beeing while arming is enabled
Door relay connected to AR-721RB (suited to models without relay built-in)
Arm relay connected to AR-721RB (suited to models with relay built-in)
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
001
002
003
004
016
032
064
128
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
2
1
323DMaster
Test
MASTER CARD Setting
Use the MASTER CARD software
Input the MASTER CARD number, and press [Write].
Cut off and tranmit the power. Activate master
the card number.
Present the card, and the reader will flash green
light 3 times and sound 3 beeps. Then the
card becomes MASTER CARD and accesses
programming mode.If MASTER CARD is presented
again, it will exit programming mode.
About Master Card / Master Card
Adding Tag
Deleting All Tags
Present Master Card
Present Master Card
P.S. Once MASTER CARD is presented after one
warning beep, all card data will be cleared.
After 3 short beeps
[Access programming mode]
After 3 short beeps
[Access programming mode]
Present one new card at a time
1 long warning beep after 2sec.
Present Master Card
[Exit programming mode]
5 short beeps after 5sec: cards cleared
1.
1.
2.
2.
3.
3.
4.
4.