Figure 15 – Overlapping Links
Note from Figure 15 that at each point of overlap either two Transmitters or two Receivers are installed. This
arrangement prevents an adjacent Transmitter and Receiver from establishing an unwanted link across the short
overlap distance. If there is an odd number of links in an installation, a transmitter and receiver will need to be
overlapped. This should be done in a corner as shown in Figure 15. Alternatively the synchronization capability
in MicroWave 330 could be utilized.
4.2 Mounting Microwave 330
Prepare a rigid mounting surface for the MicroWave 330 Transmitter and Receiver as shown in Figure 16.
Ground Lug
1/2" (1.3cm)
Flexible
Conduit
4" (10.2cm) O.D.
Galvanized Pipe
Cap
Gnd. Lug & Wire
#6 AWG
Ground Bus
Install Per Local
Electrical Code
Concrete
Tamper, Com, Sync and Power Lines
24" (61cm)
Grounding
Rod
per Local
Electrical
Code
36"
(0.91m)
Nominal
48"
(1.22m)
Nominal
Figure 16 – Mounting Detail