SOUTHWORTH
PALLET LIFT TRUCK MANUAL
13
BATTERY CHARGING
Charging must be performed with the charger that is provided and prewired
into the machine. During charging, the temperature in the battery must not ex-
ceed 120° F. Charging simultaneously with truck operation is not recommen-
ded. Plug the charger into a 115V outlet. Charge until the battery gauge indica-
tor lights show fully charged (approximately 6-8 hours).
WARNINGS AND INFORMATION ON BATTERY
Avoid the use of open flame batteries. At temperatures around the freezing
point, battery capacity is reduced by 30%. The battery terminals, connections
and wiring should be clean and free of corrosion. When cleaning any of these
components wear a face shield or other suitable protective eyewear.
Read, understand and follow all battery and battery charger manufacturer’s
specific precautions while working with and/or charging batteries. The bat-
tery used in this machine is an AGM (Absorbed Glass Mat) type and allows
safe trouble-free performance. There is no need to add electrolyte. No special
handling is required and it is classified as non-hazardous.
BATTERY MAINTENANCE:
To measure the voltage, use a voltmeter (DC) on the battery poles. The truck
must not have been in use for the previous 30 minutes.
Approx. 12.7 V
Fully charged
Approx. 12.2 V
1/2 charged
Approx. 12.0 V
1/4 charged
Approx. 11.6 V
Discharged
WARNING: IF THESE INSTRUCTIONS ARE NOT CLEAR
OR IF THERE ARE ANY QUESTIONS,
PLEASE CONTACT SOUTHWORTH PRODUCTS CORP
Telephone 1-800-743-1000 or Fax 207-797-4734
E-mail: [email protected]