Southwood RG4 Owner'S Operation Manual Download Page 11

PROBLEM 

CAUSE SOLUTION

Burners do not ignite 

No gas flow 

Check Gas valves

Burner ignites then goes out 

Air intake blocked. 

Adjust air intake

or is too weak 

Low gas Pressure 

Check Gas Pressure

 

Wrong gas type 

Check Nat/LP gas orifice

 

No or wrong Regulator 

Check gas regulator

Burner Backfires 

Too much primary air 

Adjust air intake

Individual Spits do not rotate 

Defective Switch 

Replace Switch

 

Defective Motor 

Replace motor

 

Improper Spit placement 

Re-seat Spit into connector

 

Loose Spit connector 

Tighten connector be - 

 

 

tween spit / motor

All spits do not rotate 

Blown fuse 

Replace fuse  (< 2 Amps)

Light does not work 

Blown Fuse 

Replace Fuse (< 2 Amps)

TROUBLESHOOTING

SOUTHWOOD

ROTISSERIE MACHINES

Southwood Manufacturing • A Division of US Restaurant Group • www.usrestaurant.com • [email protected] • (800)-764-1172

IMPORTANT FUSE INFORMATION

Left fuse is for light bulb. Right fuse is for motor. 

DO NOT INSERT ANY FUSE GREATER THAN 2 AMPS

1 or 2 amp fuses may be used in these machines. Never above 2 Amps. Generally if both 

the lights and the spits are not working, this is because teh fuses need to be replaced.  

Summary of Contents for RG4

Page 1: ...SA Models RG4 RG7 Model RG7 Total BTU 170 100 Burners 3 Ignition Manual Spits 7 Model RG4 Total BTU 56 700 Burners 1 Ignition Manual Spits 4 Southwood Manufacturing A Division of US Restaurant Group w...

Page 2: ...is machine This unit does not have a built in regu lator The gas regulator must match the gas type and is required for operation 6 This unit features a 1 2 gas intake pipe Any gas hose or disconnect s...

Page 3: ...on S S Equip Stand 48 25 Includes 5 Spit Handles Includes 5 Casters 23 25 RG7 76 RG4 48 FRONT SIDE TOP 36 21 5 4 SOUTHWOOD ROTISSERIE MACHINES DRAWINGS AND DIMENSIONS Southwood Manufacturing A Divisio...

Page 4: ...lve Traffic 25 m3 H 25kg H Static Pressure 2000 400Pa 2800 600Pa Min Pressure 1600Pa 2200Pa MODEL RG4 RG7 VOLTAGE 110V 1PH 8A 55W 110V 1PH 8A 100W FREQUENCY Hz 60 50 Available 60 50 Available TEMPERAT...

Page 5: ...rd also check the regulator If this is correct verify the pressure coming out of the main gas meter or the diameter of the gas pipe feeding gas to the unit If the gas line is under sized the appropria...

Page 6: ...g when front glass door is open Manual Gas Valve Venturi Spit Plate Air intake Cap DO NOT COVER OR SEAL Adjustment must be made at installation or gas type change Cali brate for blue flame Southwood M...

Page 7: ...red 1 4 Glass Only Drippings Drawer Add water for humidity and to catch the chicken grease Ceramic Bricks Place ON Burner 1 space between bricks Southwood Manufacturing A Division of US Restaurant Gro...

Page 8: ...on new moved or convert ed machines Calibrate to achieve Blue colored flame Turn OFF at the end of each use and before any installation repair or maintenance DO NOT SEAL OR COVER THIS AIR IN TAKE Sout...

Page 9: ...nd other food into the skewers Adjust the dis tance between the skewers When finished shut the side door and the front glass door Observe the product when roasting Change the direction of rotation of...

Page 10: ...or surfaces carefully cover protect or remove all ceramics 5 The interior stainless steel surfaces can be sprayed with a de greaser for best results 6 For best results on the interior metal use a stea...

Page 11: ...Re seat Spit into connector Loose Spit connector Tighten connector be tween spit motor All spits do not rotate Blown fuse Replace fuse 2 Amps Light does not work Blown Fuse Replace Fuse 2 Amps TROUBLE...

Page 12: ...nd open for accessible for proper maintenance and use 5 Keep this machine free and clear from combustibles Do not store or use gasoline or other flammables in the vicinity of this machine 6 Do not ob...

Reviews: