6

Symbols Used

on LCD Display

RANGE BUTTON

  When the meter is first turned on, it goes into Autoranging.

This automatically selects the best range for the measurements being made and is

generally the best mode for most measurements. For measurement situations requiring

that a range be manually selected, perform the following:  1. Press the 

RANGE

 button.

The 

“AUTO”

 display indicator will turn off.  2. Press the 

RANGE

 button to step through

the available ranges until you select the range you want.  3. Press and hold the 

RANGE

button for 2 seconds to exit the Manual Ranging mode and return to Autoranging.

V Volts
A Amps
AC 

Alternating current

DC 

Direct current

Minus sign

Ω 

Ohms

•))) Continuity
 

Diode test

Farads (capacitance)

Hz 

Hertz (frequency) 

Percent (duty cycle)

ºF 

Degrees Fahrenheit

ºC 

Degrees Centigrade              

AUTO 

Autoranging

REL Relative
HOLD 

Display hold

 

Battery status

n nano 

(10

-9

µ micro 

(10

-6

m milli 

(10

-3

k kilo 

(10

3

M mega 

(10

6

)

OL 

Overload 

5

Meter Description

1.  Current clamp

2.  Non-contact AC voltage indicator light

3.  Clamp trigger

4.  Data Hold/Backlight button

5.  Rotary function switch

6.  Frequency/Duty Cycle button

7.  RANGE select button

8.  MODE select button

9.  Relative button

10. MAX/MIN button

11. LCD display

12. COM input jack

13. V, Ω, CAP, Temp, Hz input jack

14. Non-contact voltage detector

AUTO

POWER

OFF

MODE

REL

MAX

MIN

RANGE

Hz%

Non-Contact

Voltage Detector

600V

CAT 

III

1.

2.

3.

6.
8.

12.

11.

14.

4.

5.

9.

7.

10.

13.

MODE BUTTON

To select AC or DC volts, Resistance/Diode

Test, Continuity, or Capacitance and °F or °C

MAX/MIN RECORDING BUTTON

Select the proper range before selecting MAX/MIN to ensure that the MAX/MIN

reading will not exceed the testing range. Press the 

MAX/MIN

 button to enter

the MAX/MIN recording mode. Press once to select MAX.

Press again to select MIN. Press for two seconds to end the MAX/MIN mode.

(MAX/MIN operates on Voltage, Current, Resistance, and Temperature functions.) 

REL BUTTON  

For DC Current Zero & Offset adjustment

DATA HOLD BUTTON  

To freeze the LCD meter reading, momentarily press the

data 

HOLD

      button. While data hold is active, the 

HOLD

 display icon appears 

on the LCD. Press the data hold button again to return to normal operation.

BACKLIGHT BUTTON  

The backlight illuminates the display when the ambient light is

too low to permit viewing of the displayed readings. Press and hold the 

HOLD      

button

for two seconds to turn the backlight on. If 

HOLD

 appears on display, clear 

HOLD

 by

momentarily pressing 

HOLD      .

Summary of Contents for 22070T

Page 1: ...verdadera 12 14 Rev 1 22070T manual Contents Made in China Product distributed by Southwire Company LLC One Southwire Drive Carrollton GA 30119 2014 Southwire Company LLC All rights reserved southwire...

Page 2: ...k hazard Do not use the meter in wet or damp environments or during electrical storms Do not use the meter near explosive vapors dust or gasses Do not use the meter if it operates incorrectly Protecti...

Page 3: ...an 60ft 20m from a CAT IV source Equipment in fixed installations such as 3 phase motors switchgear and distribution panels Lighting circuits in commercial buildings Feeder lines in industrial plants...

Page 4: ...7 RANGE select button 8 MODE select button 9 Relative button 10 MAX MIN button 11 LCD display 12 COM input jack 13 V CAP Temp Hz input jack 14 Non contact voltage detector AUTO POWER OFF MODE REL MAX...

Page 5: ...ety precautions when working on live conductors WARNINGS 8 1 Set the rotary function switch to the VAC DC Hz position 2 Insert the black test lead into the negative COM input jack and the red test lea...

Page 6: ...est lead probes to the device or wire being tested 5 A tone will sound if the resistance is approximately 30 ohms or less 10 Capacitance Measurements Operation cont 1 Set the rotary function switch to...

Page 7: ...ts Operation cont 1 Set the rotary function switch to the Temp 0 F 0 C position 2 Push the to select readings in F or C 3 Connect the Temperature Probe to the Banana Plug Adapter Insert the adapter in...

Page 8: ...ny LLC warrants this product to be free from defects in material and workmanship for two years from the date of purchase This warranty does not cover fuses disposable batteries or damage arising from...

Reviews: