Southern Cross SBI 1 Installation And Operating Instructions Manual Download Page 9

SBI, SBN 1, 3, 5 Coupling Adjustment

SBI/SBN Vertical Multistage Centrifugal Pumps

8

1

2

3

4

L

H

DN

L

1

L

2

B

1

B

2

4xø

Pump

L

H

DN

L

1

L

2

B

1

B

2

Ø

Type

mm

mm

mm

mm

mm

mm

mm

mm

SBI 1

250

75

25/32 100

150

180

220

14

SBI 3

250

75

25/32 100

150

180

220

14

SBI 5

250

75

25/32 100

150

180

220

14

SBI 10

280

80

40

130

200

215

248

14

SBI 15

300

90

50

130

200

215

248

14

SBI 20

300

90

50

130

200

215

248

14

SBI 32

320

105

65

170

225

240

297

14

SBI 45

365

140

80

190

251

265

330

14

SBI64

365

142

100

188

247

268

330

14

SBI90         380       140       100      199       260       280      345         14

Summary of Contents for SBI 1

Page 1: ...Installation and Operating Instructions VERTICAL MULTI STAGE CENTRIFUGAL PUMPS Models 1 3 5 10 15 20 32 45 64 90...

Page 2: ...your Southern Cross Dealer for information about special pump versions and applications 3 Applications SBI and SBN series in line pumps booster pumps are designed for a wide range of applications in v...

Page 3: ...occurs Cavitation will cause pump damage and the resultant damage is not subject to warranty 4 4 Minimum nominal flow rate To prevent overheating of the internal pump components the pump should not be...

Page 4: ...mp intake and after the pump discharge 3 Use flexible piping on both inlet and outlet sides of the pump to reduce vibration and transmission of noise 4 Check valves will prevent return flow of pumped...

Page 5: ...phase are suitable for the motor used Before proceeding make sure that all the connections are grounded and well insulated Overload protection should be provided To connect proceed as shown on the ins...

Page 6: ...en the bypass valve during start up The bypass valve connects the suction and discharge sides of the pump thus making the filling procedure easier When the operation is stable the bypass valve can be...

Page 7: ...a The voltage is not within the motor s operating limits Check the operating conditions of the pump but after a short b The control panel is situated in an excessively heated Protect the control pane...

Page 8: ...r SBI SBN 3 2 36 25 bar 2 29 10 bar 31 36 15 bar SBI SBN 5 2 36 25 bar 2 16 10 bar 18 36 15 bar SBI SBN 10 1 16 16 bar 1 6 8 bar 17 22 25 bar 7 22 10 bar SBI SBN 15 1 10 16 bar 1 3 8 bar 12 17 25 bar...

Page 9: ...BI 1 250 75 25 32 100 150 180 220 14 SBI 3 250 75 25 32 100 150 180 220 14 SBI 5 250 75 25 32 100 150 180 220 14 SBI 10 280 80 40 130 200 215 248 14 SBI 15 300 90 50 130 200 215 248 14 SBI 20 300 90 5...

Page 10: ...SBI SBN 10 15 20 32 45 64 Coupling Adjustment SBI SBN Vertical Multistage Centrifugal Pumps 9 1 2 3 4 5 6...

Page 11: ...Form 2825 Dec 2009 Telephone 131 PUMP www tycopumpingsystems com SBI SBN Vertical Multistage Centrifugal Pumps...