Figure 23

  

 

Wiring Diagram for 115 Volt and 208/220/240 Volt Models 

 

 

HIGH LIMIT TSTATS 

Summary of Contents for StratoSteam STRG-3D

Page 1: ...erty damage injury or death Read installation operation and maintenance instructions thoroughly before installing or servicing this equipment 1100 Old Honeycutt Road Fuquay Varina NC 27526 USA www sou...

Page 2: ...HAZARD Contact with hot surfaces will cause severe burns Always use caution when operating cooking appliances Stand back when opening the steamer door as hot steam or hot water may escape from the doo...

Page 3: ...and STRG 5D The manual is divided into six sections Introduction 3 Specifications 4 Operation 7 Cleaning Maintenance 11 Installation 13 Service 20 Each steamer has two serial plates located on the ex...

Page 4: ...e specifications and product design without notice Such revisions do not entitle the buyer to corresponding changes additions or replacements for previously purchased equipment This product is intende...

Page 5: ...x Overflow Vent Drain Connection 1 NPT 24 611 6 152 23 3 4 606 Cabinet Base optional Model STRG 5D Model STRG 3D 2 52 29 1 2 749 37 1 2 953 including 8 204 minimum rear clearance Dimensions shown in i...

Page 6: ...tural Gas 4 W C Propane Gas 10 W C INCOMING Natural Gas 7 W C Minimum Propane Gas 11 W C WATER REQUIREMENTS To meet warranty requirements the water supply must be as follows Connection 1 4 compression...

Page 7: ...rily shuts off while the door is open Timer can be used as a reminder to the operator The timer does NOT turn the steamer on or off SHUTDOWN Turn lever to the OFF position The water in the bottom of t...

Page 8: ...erve water and electricity during idle periods Timer Set for up to 60 minutes as a reminder to operator DOES NOT CONTROL STEAMER When buzzer sounds turn knob counterclockwise to silence the buzzer Pow...

Page 9: ...r fish may be browned in an infra red or radiant broiler after steaming by brushing with melted margarine mixed with salad oil to give a golden brown color Save juices from steamed meat and poultry to...

Page 10: ...3D Cooking Time minutes STRG 5D Cooking Time minutes Eggs 18 48 8 9 9 10 Potatoes Red 4 lbs 8 lbs 21 21 21 21 Rice 2 lbs 3 lbs 19 19 20 20 Shrimp Frozen 2 5 lbs 8 lbs 7 10 7 10 Corn Frozen 2 5 lbs 7...

Page 11: ...allic pads in the steamer 1 Turn control lever to OFF and allow time for the steamer to drain and cool 2 Remove and clean pans 3 Remove and clean pan supports and cavity bottom cover Wash separately i...

Page 12: ...y rubbing the surface with SCOTCH BRITE scouring pads or STAINLESS scouring pads DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and further spoil the appearance of the f...

Page 13: ...e NEC or ANSI NFPA70 NOTE In Canada the oven installation must conform with local codes or in the absence of local codes with the Natural Gas Installation Code CAN CGA B149 1 or the Propane Gas Instal...

Page 14: ...ny tags or labels attached to the steamer until the steamer is installed and working properly 2 If the steamer was shipped on a wooden skid cut the banding strap holding the steamer to the wooden skid...

Page 15: ...es of the steamer see Figure 5 5 Go on to Installation Step 3 Figure 5 Installation on Countertop STEP 2C MOUNTING ON CABINET BASE If the steamer is to be mounted on the optional cabinet base first at...

Page 16: ...hort as possible There should be no horizontal piping between the steamer and the air gap above the open funnel The open funnel is intended to eliminate any water from entering the steamer because of...

Page 17: ...PPM or less Hardness 2 grains 35 PPM or less pH 7 0 to 7 5 Chlorine and or bromine 1 PPM or less Connect a cold water line to the water inlet strainer on the back of the steamer as shown in Figure 6...

Page 18: ...preciable drop Fluctuations of more than 25 on natural gas and 10 on propane gas will create problems and affect burner operation Contact your gas company for correct supply line sizes Purge the suppl...

Page 19: ...BE PROPERLY GROUNDED IF THE RECEPTACLE IS NOT THE PROPER GROUNDING TYPE CONTACT AN ELECTRICIAN DO NOT REMOVE THE GROUNDING PRONG FROM THE PLUG Refer to the data plates located on the upper left front...

Page 20: ...t 6 Wait four minutes then check that some water has covered the bottom of the cavity 7 Depress the door switch actuator rod and listen for an audible click Release the door switch actuator rod and li...

Page 21: ...ANCE AND REPAIR A serial plate is located on the right side of the steamer near the top right corner A second serial plate is located on the rear of the steamer near the top left corner see Figure 1 o...

Page 22: ...the circuitry The Power indicator light comes on Turning the control lever to ON also mechanically closes the cooking cavity drain valve The gas ignition system is energized turning on the gas valve i...

Page 23: ...Buzzer behind panel Terminal Block Thermometer Control Lever On Off Power Switch behind panel Flame Sensor Rod Connecting Control Lever to Drain Valve IR Gas Heaters 4 Gas Valve Regulator Drain Box D...

Page 24: ...eplace Power light and follow procedure Replace Power Cord Check continuity across Power Switch Is continuity present No Yes DISCONNECT POWER AT CIRCUIT BREAKER Remove right side panel for access Reco...

Page 25: ...path for obstructions Turn steamer back on and wait 10 minutes High limit thermostats OK No Yes Replace high limit thermostats as necessary DISCONNECT POWER AT CIRCUIT BREAKER Check that water supply...

Page 26: ...When Timer Runs Out Disconnect buzzer lead wires from the timer Buzzer does not come on when timer runs out Replace timer Replace buzzer Timer OK No Yes DISCONNECT POWER AT CIRCUIT BREAKER No Yes Doe...

Page 27: ...n Hot surface ignitor glows red but burners will not turn on Open valve Is manual shutoff valve open Replace transformer Replace ignition module Position ignitor correctly Replace gas valve Is there 2...

Page 28: ...oltage is present replace transformer If voltage is not present check Door Switch see page 33 Check connections to ignition module Replace ignitor module Replace ignitor Check wiring to ignitor Is the...

Page 29: ...gas pressure to correct level Align burners and orifices Each orifice must inject gas down the direct center of the burner Make sure burner orifices are not clogged and are the correct size Natural G...

Page 30: ...ner does not ignite ignition module will try three times and then lock out Replace ignition module Replace gas valve Check that flame sensor is properly positioned If it is and sensor current is still...

Page 31: ...al board and the other test lead on Pin 3 of connector PL1 the socket half which is wired to the control panel 6 Check for continuity with control lever in OFF position there should not be continuity...

Page 32: ...onnect from the timer the wire that leads to the buzzer 5 Disconnect connector PL1 to separate the other buzzer lead wire from the wiring harness 6 Place test leads between positions 1 and 3 on the ti...

Page 33: ...r switch when the rod moves 4 Disconnect the wiring harness from the switch terminals at the two places shown above where the test probe tips are located 5 Place the test probes on the switch terminal...

Page 34: ...T POWER AT CIRCUIT BREAKER 3 Remove left side panel 4 Disconnect wire B4 from left as shown above high limit thermostat 5 Disconnect wire B5 from right high limit thermostat 6 Disconnect remaining hig...

Page 35: ...be approximately 800 ohms Replace if necessary 6 Apply waterline pressure to water inlet Water should not leak out of the compression fittings If necessary replace water solenoid Check to see that wat...

Page 36: ...SERVICE STRATOSTEAM GAS COUNTERTOP STEAMER PAGE 36 OF 56 OWNER S MANUAL 1189952 10 08 Figure 23 Wiring Diagram for 115 Volt and 208 220 240 Volt Models HIGH LIMIT TSTATS...

Page 37: ...end Authorized Service Agency Parts Diagram Page Door Assembly Parts for units built on or after January 7 2008 38 Door Assembly Parts for units built before January 7 2008 39 Structural Parts 40 Cont...

Page 38: ...NEL EXTERIOR DOOR for STRG 5D 3 1183430 3 SCREW 10 32X1 4 SS RND HD 4 1189580 1 BRACKET DOOR LATCH COVER 5 1149902 2 SCREW 10X1 2 PHIL TRUSS HEAD 6 1189738 1 DOOR INS COVER S A for STRG 3D 1189739 1 D...

Page 39: ...27 6 WASHER 10 LOCK SS 300 4 1146526 4 WASHER 10 FLAT 5 1185053 1 PANEL W A R2 STACKABLE 6 1185028 2 HINGE PLATE W A 7 1185115 1 GASKET DOOR R2 REDESIGN 8 1146268 2 BOLT 1 4 20X5 8 HEX HEAD SS 9 66004...

Page 40: ...8 1189400 1 DOOR GASKET STRG 5D for units built on or after January 7 2008 4 1185072 1 1 DOOR SWITCH ASSEMBLY see page 45 for individual parts 5 1185036 1 1 FLOOR PANEL 6 1185103 1 SIDEWALL ASSEMBLY S...

Page 41: ...STRATOSTEAM GAS COUNTERTOP STEAMER SERVICE OWNER S MANUAL 1189952 10 08 PAGE 41 OF 56 Figure 26 3 4 1 2 6 7 8 9 10 9 15 12 13 16 17 19 5 20 11 14 18 Structural Parts See parts list on previous page...

Page 42: ...3 SCREW 6 32X3 8 SS PHIL PAN HD 10 1170350 1 LIGHT AMBER 240V SIGNAL 11 1185058 1 POLYPANEL CONTROL 12 1190842 1 FRONT PANEL W A for STRG 3D 1190843 1 FRONT PANEL W A for STRG 5D 13 1185782 2 BOLT SH...

Page 43: ...P STEAMER SERVICE OWNER S MANUAL 1189952 10 08 PAGE 43 OF 56 Figure 27 5 6 1 2 7 8 9 10 11 12 15 16 13 14 17 18 19 20 21 23 22 24 3 4 25 Control Parts for units built on or after January 7 2008 See pa...

Page 44: ...1 GUAGE THERMOMETER 2 IN 5 1170350 1 LIGHT AMBER 240V SIGNAL 6 1178388 1 VALVE LEVER W A 7 1177770 1 BUSHING VALVE LEVER MOUNT 8 1177865 1 NUT HEX 5 8 18 BRASS 9 1178276 1 CAM ACTUATOR 10 1178549 1 SC...

Page 45: ...ered see page 40 Key Part Number Qty Description 1 1185070 1 ARM DOOR SW SWING STRATOSTEAM 2 1185071 1 BRACKET W A STRATOSTEAM DOOR SWITCH 3 1185195 1 SWITCH DOOR SPDT 15 AMP SUBMINIATURE 4 1146320 2...

Page 46: ...T SURFACE IGNITOR 4 1175127 1 FLAME SENSOR 5 1185264 2 BRACKET BURNER HOLD DOWN 6 1175723 1 IGNITION MODULE 7 1172277 1 24V AC TRANSFORMER 8 1175547 1 GROUND LUG 9 1170335 1 6 POSITION TERMINAL BLOCK...

Page 47: ...AS COUNTERTOP STEAMER SERVICE OWNER S MANUAL 1189952 10 08 PAGE 47 OF 56 Figure 30 3 4 1 2 5 6 7 8 9 10 13 14 11 12 15 16 17 Burner Assemblies Thermocouple and Ignition Module Parts See parts list on...

Page 48: ...TER VALVE 115 VAC 5 1176384 1 NIPPLE CLOSE 1 8 NPT X 3 4 LONG 6 1184260 1 STRAINER Y IN LINE 1 8 NPT FEM 7 1184261 1 TEE 1 8 STREET 8 1184262 1 REDUCER 3 8 TO 1 8 MPT 9 1185149 1 TUBE 1 4 WATER INLET...

Page 49: ...STRATOSTEAM GAS COUNTERTOP STEAMER SERVICE OWNER S MANUAL 1189952 10 08 PAGE 49 OF 56 Figure 31 Water Train Parts See parts list on previous page...

Page 50: ...1183983 1 HINGE ASSEMBLY UPPER RIGHT 6 1183984 1 HINGE ASEMBLY LOWER RIGHT 1183986 1 HINGE ASSEMBLY LOWER LEFT 7 1184527 1 COVER 24 BASE BOTTOM 8 1185141 1 BODY SIDE CAB SS OPEN LT 9 1185144 1 PANEL...

Page 51: ...STRATOSTEAM GAS COUNTERTOP STEAMER SERVICE OWNER S MANUAL 1189952 10 08 PAGE 51 OF 56 Figure 32 3 4 1 2 5 6 7 8 9 10 13 14 11 12 15 Cabinet Base Parts See parts list on previous page...

Page 52: ...STRATOSTEAM GAS COUNTERTOP STEAMER PAGE 52 OF 56 OWNER S MANUAL 1189952 10 08 Notes...

Page 53: ...STRATOSTEAM GAS COUNTERTOP STEAMER OWNER S MANUAL 1189952 10 08 PAGE 53 OF 56 Notes...

Page 54: ...STRATOSTEAM GAS COUNTERTOP STEAMER PAGE 54 OF 56 OWNER S MANUAL 1189952 10 08 Notes...

Page 55: ...STRATOSTEAM GAS COUNTERTOP STEAMER OWNER S MANUAL 1189952 10 08 PAGE 55 OF 56 Notes...

Page 56: ...w maintenance We all recognize however that replacement parts and occasional professional service may be necessary to extend the useful life of this appliance When service is needed contact a Southben...