I
NSTALLATION
EZ C
OM
C
OMBINATION
O
VEN
P
AGE
8
O
PERATOR
’
S
M
ANUAL
1182851
REV
2
INSTALLATION
Step 2: Install the Legs and/or Casters
For Model CG/12SC (single-oven) units, a set of legs and a set of casters is packed in the shipping crate.
Install the legs and casters using the following procedure:
1. Raise the EZ Com sufficiently to allow legs to be bolted to the bottom corners. For safety, “shore up”
and support the oven with an adequate blocking arrangement strong enough to support the load.
2. Bolt the legs to the bottom of the oven.
3. Screw the four casters into the threaded holes in the bottom of each leg. The two casters with a locking-
brake should be attached to the front legs of the EZ Com.
4. Gently lower the EZ Com onto a level surface. Never drop or allow the oven to fall.
5. Use a level to make sure that the EZ Com is level. Each caster can be screwed in or out to lower or raise
each corner. Tighten the lock nuts after the EZ Com has been leveled.
For Model CG/22SC (double-oven) units, a set of casters is packed in the shipping crate. Install the casters
using the following procedure:
1. Raise the EZ Com sufficiently to allow casters to be bolted to the bottom corners. For safety, “shore up”
and support the oven with an adequate blocking arrangement strong enough to support the load.
2. Screw the four casters into the threaded holes in the bottom corners of the EZ Com. The two casters
with a locking-brake should be attached to the front corners.
3. Gently lower the EZ Com onto a level surface. Never drop or allow the oven to fall.
4. Use a level to make sure that the EZ Com is level. Each caster can be screwed in or out to lower or raise
each corner. Tighten the lock nuts after the EZ Com has been leveled.
NOTICE
Unit must be level to assure maximum performance. Improper leveling may void warranty.
NOTICE
Adequate restraining means must be attached to rear of appliance when installed. Installation must
conform to local codes as applicable.
!
WARNING
For an appliance equipped with casters, the installation shall be made with a connector that complies
with the Standard for
Connectors for Movable Gas Appliances, ANSI Z21.69
or Connectors for
Moveable Gas Appliances, CAN/CGA-6.16
, and a quick-disconnect device that complies with the
Standard for
Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41
,
or Quick Disconnect
Devices for Use with Gas Fuel, CAN1-6.9
. Adequate means must be provided to limit the movement
of the appliance without depending on the connector and the quick-disconnect device or its
associated piping to limit the appliance movement.
!
WARNING
If disconnection of this restraint is necessary to move the appliance for cleaning, etc., reconnect it
when the appliance is moved to it originally installed position.