background image

Mfg. Since 6/10

Model SB1044

-3-

I N S T R U C T I O N S

Operation

Only use high quality water-soluble cutting 

fluid in this system. Never attempt to pump 

straight cutting oils or kerosene. If you do, the 

higher viscosity of the oil will overload the motor, 

causing damage, or flammable liquids may 

ignite.

Following the cutting fluid manufacturer’s 

guidelines, check and maintain the specific 

gravity of the cutting fluid to its required level. 

Change the fluid when it becomes overly dirty, 

rancid, or contaminated.

To use the cutting fluid system:

1.

  Make sure the cutting fluid is properly 

serviced and the tank is filled. 

2.

  Put on the necessary personal protection 

equipment.

3.

  Position the cutting fluid nozzle for your 

operation.

4.

  Use the control panel coolant switch to turn 

the cutting fluid pump ON.

Figure 3. SB1029 control panel.

5.

  Adjust the flow of cutting fluid for the type of 

flooding required.

Note:

 Promptly clean any splashed cutting fluid 

from the floor to avoid a slipping hazard.

Coolant Switch

BIOLOGICAL & POISON 

HAZARD!

Use the correct personal 

protection equipment 

when handling cutting 

fluid. Follow federal, state, 

and fluid manufacturer 

requirements for proper 

disposal.

Running the pump without adequate fluid in 

the tank may permanently damage it. This 

damage is not covered by warranty.

Summary of Contents for SB1044

Page 1: ...lts especially on materials that should not be ground dry Figure 1 Model SB1044 Unpacking This item was carefully packaged to prevent damage during transport If you discover any damage please immediat...

Page 2: ...ose clamp 9 Route the delivery hose out of the way and fasten the delivery hose to your desired cutting fluid nozzle with the hose clamp 10 Fill the tank with premixed water soluble cutting fluid To i...

Page 3: ...sure the cutting fluid is properly serviced and the tank is filled 2 Put on the necessary personal protection equipment 3 Position the cutting fluid nozzle for your operation 4 Use the control panel c...

Page 4: ...is turned ON 5 Open the flow lever on your cutting fluid nozzle all the way open and turn the cutting fluid pump ON Do not leave the area as you will need transfer the hose to the other bucket to prev...

Page 5: ...is obstructing pump suction or impeller is damaged Remove pump remove impeller cover clean and replace as required 8 Plug or receptacle is corroded or mis wired 8 Clean retighten contacts correct the...

Page 6: ...serious injury or fire 4 Motor Wiring The motor wiring shown in these diagrams is current at the time of printing but it may not match your machine Always use the wiring diagram inside the motor junc...

Page 7: ...mp To Motor To Power Cord 0 W1 V1 U1 W1 V1 U1 NO 98 Ground 3 2 1 4 6 5 W1 V1 U1 Gn OPTIONAL 440V 3 PHASE CONNECTION W V U 0 7 6 4 3 2 R1 T1 1 T1 R1 R1 R1 1 1 1 1 2 2 2 3 3 6 7 3 3 0 0 U U V V W W 4 4...

Page 8: ...chantability or fitness for any purpose are hereby limited to the duration of this warranty To take advantage of this warranty contact us by mail or phone to give us the details of the problem you are...

Reviews: